Usability of semiautomatic segmentation algorithms for tumor volume determination

Rationale and objectives: Tumor volume is an important parameter for clinical decision making. At present, semiautomatic image segmentation is not a standard for tumor volumetry. The aim of this work was to investigate the usability of semiautomatic algorithms for tumor volume determination. Methods...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mahr, Andreas (VerfasserIn) , Levegrün, Sabine (VerfasserIn) , Bahner, Malte Leonardo (VerfasserIn) , Kreß, Jürgen (VerfasserIn) , Schlegel, Wolfgang (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1999
In: Investigative radiology
Year: 1999, Jahrgang: 34, Heft: 2, Pages: 143-150
ISSN:1536-0210
Online-Zugang:Verlag, Volltext: http://ovidsp.tx.ovid.com/sp-3.32.2a/ovidweb.cgi?&S=DEKFFPFPKNDDCJDGNCDKGEIBJBABAA00&Link+Set=S.sh.22.23.27.31%7c7%7csl_10
Volltext
Verfasserangaben:Andreas Mahr, Sabine Levegrün, Malte L. Bahner, Jürgen Kress, Ivan Zuna, Wolfgang Schlegel

MARC

LEADER 00000caa a2200000 c 4500
001 1587823152
003 DE-627
005 20220815105928.0
007 cr uuu---uuuuu
008 190220s1999 xx |||||o 00| ||eng c
035 |a (DE-627)1587823152 
035 |a (DE-576)517823152 
035 |a (DE-599)BSZ517823152 
035 |a (OCoLC)1341038799 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mahr, Andreas  |d 1971-  |e VerfasserIn  |0 (DE-588)121602842  |0 (DE-627)705567184  |0 (DE-576)292793820  |4 aut 
245 1 0 |a Usability of semiautomatic segmentation algorithms for tumor volume determination  |c Andreas Mahr, Sabine Levegrün, Malte L. Bahner, Jürgen Kress, Ivan Zuna, Wolfgang Schlegel 
264 1 |c 1999 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.02.2019 
520 |a Rationale and objectives: Tumor volume is an important parameter for clinical decision making. At present, semiautomatic image segmentation is not a standard for tumor volumetry. The aim of this work was to investigate the usability of semiautomatic algorithms for tumor volume determination. Methods: Semiautomatic region- and volume-growing, isocontour, snakes, hierarchical, and histogram-based segmentation algorithms were tested for accuracy, contour variability, and time performance. The test were performed on a newly developed organic phantom for the simulation of a human liver and liver metastases. The real tumor volumes were measured by water displacement. These measured volumes were used as the gold standard for determining the accuracy of the algorithms. Results: Variability of the segmented volumes ranging from 3.9 ± 3.2% (isocontour algorithm) to 11.5 ± 13.9% (hierarchical segmentation) was observed. The segmentation time per slice varied between 32 (volume-growing) and 72 seconds (snakes) on an IBM/RS6000 workstation. Conclusions: Only the region-growing and isocontour algorithms have the potential to be used for tumor volumetry. However, further improvements of these algorithms are necessary before they can be placed into clinical use. 
700 1 |a Levegrün, Sabine  |e VerfasserIn  |0 (DE-588)1178459055  |0 (DE-627)1049387597  |0 (DE-576)517789329  |4 aut 
700 1 |a Bahner, Malte Leonardo  |e VerfasserIn  |0 (DE-588)1077114923  |0 (DE-627)836029720  |0 (DE-576)169751422  |4 aut 
700 1 |a Kreß, Jürgen  |e VerfasserIn  |0 (DE-588)1178559068  |0 (DE-627)104944938X  |0 (DE-576)517823888  |4 aut 
700 1 |a Schlegel, Wolfgang  |d 1945-  |e VerfasserIn  |0 (DE-588)130450960  |0 (DE-627)501843698  |0 (DE-576)298203219  |4 aut 
773 0 8 |i Enthalten in  |t Investigative radiology  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1966  |g 34(1999), 2, Seite 143-150  |h Online-Ressource  |w (DE-627)326645322  |w (DE-600)2041543-6  |w (DE-576)09442568X  |x 1536-0210  |7 nnas  |a Usability of semiautomatic segmentation algorithms for tumor volume determination 
773 1 8 |g volume:34  |g year:1999  |g number:2  |g pages:143-150  |g extent:8  |a Usability of semiautomatic segmentation algorithms for tumor volume determination 
856 4 0 |u http://ovidsp.tx.ovid.com/sp-3.32.2a/ovidweb.cgi?&S=DEKFFPFPKNDDCJDGNCDKGEIBJBABAA00&Link+Set=S.sh.22.23.27.31%7c7%7csl_10  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190220 
993 |a Article 
994 |a 1999 
998 |g 130450960  |a Schlegel, Wolfgang  |m 130450960:Schlegel, Wolfgang  |d 50000  |e 50000PS130450960  |k 0/50000/  |p 6  |y j 
998 |g 1178559068  |a Kreß, Jürgen  |m 1178559068:Kreß, Jürgen  |d 50000  |e 50000PK1178559068  |k 0/50000/  |p 4 
998 |g 1077114923  |a Bahner, Malte Leonardo  |m 1077114923:Bahner, Malte Leonardo  |d 50000  |e 50000PB1077114923  |k 0/50000/  |p 3 
998 |g 1178459055  |a Levegrün, Sabine  |m 1178459055:Levegrün, Sabine  |d 50000  |e 50000PL1178459055  |k 0/50000/  |p 2 
998 |g 121602842  |a Mahr, Andreas  |m 121602842:Mahr, Andreas  |d 50000  |e 50000PM121602842  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1587823152  |e 3056238471 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 20.02.2019"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1587823152","language":["eng"],"person":[{"given":"Andreas","family":"Mahr","role":"aut","roleDisplay":"VerfasserIn","display":"Mahr, Andreas"},{"roleDisplay":"VerfasserIn","display":"Levegrün, Sabine","role":"aut","family":"Levegrün","given":"Sabine"},{"family":"Bahner","given":"Malte Leonardo","display":"Bahner, Malte Leonardo","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Jürgen","family":"Kreß","role":"aut","display":"Kreß, Jürgen","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","display":"Schlegel, Wolfgang","role":"aut","family":"Schlegel","given":"Wolfgang"}],"title":[{"title_sort":"Usability of semiautomatic segmentation algorithms for tumor volume determination","title":"Usability of semiautomatic segmentation algorithms for tumor volume determination"}],"physDesc":[{"extent":"8 S."}],"relHost":[{"language":["eng"],"recId":"326645322","type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Usability of semiautomatic segmentation algorithms for tumor volume determinationInvestigative radiology","note":["Gesehen am 01.03.11"],"part":{"issue":"2","pages":"143-150","year":"1999","extent":"8","volume":"34","text":"34(1999), 2, Seite 143-150"},"pubHistory":["1.1966 -"],"title":[{"title_sort":"Investigative radiology","subtitle":"a journal of clinical and laboratory research","title":"Investigative radiology"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1536-0210"],"zdb":["2041543-6"],"eki":["326645322"]},"origin":[{"publisherPlace":"Philadelphia, Pa. ; [Erscheinungsort nicht ermittelbar]","dateIssuedDisp":"1966-","dateIssuedKey":"1966","publisher":"Lippincott Williams & Wilkins ; Ovid"}]}],"name":{"displayForm":["Andreas Mahr, Sabine Levegrün, Malte L. Bahner, Jürgen Kress, Ivan Zuna, Wolfgang Schlegel"]},"origin":[{"dateIssuedDisp":"1999","dateIssuedKey":"1999"}],"id":{"eki":["1587823152"]}} 
SRT |a MAHRANDREAUSABILITYO1999