Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft: early and 2 year results from a European Multicentre Registry

Objective: To assess safety, effectiveness and clinical outcome of the conformable thoracic aortic endograft (CTAG) in the treatment of aortic arch pathologies. Methods: Between October 2009 and December 2010, 100 consecutive patients (65 men; mean age 65 years) with aortic arch pathologies were tre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Böckler, Dittmar (VerfasserIn) , Hyhlik-Dürr, Alexander (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 20 April 2016
In: European journal of vascular and endovascular surgery
Year: 2016, Jahrgang: 51, Heft: 6, Pages: 791-800
ISSN:1532-2165
DOI:10.1016/j.ejvs.2016.02.006
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.ejvs.2016.02.006
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1078588416000988
Volltext
Verfasserangaben:D. Böckler, J. Brunkwall, P.R. Taylor, N. Mangialardi, J. Hüsing, T. Larzon, Alexander Hyhlik-Dürr, Michael Gawenda, Rachel Clough, Sonja Ronchey, Lena Örman, on behalf of the CTAG registry investigators

MARC

LEADER 00000caa a2200000 c 4500
001 1590308468
003 DE-627
005 20240316100557.0
007 cr uuu---uuuuu
008 190314s2016 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejvs.2016.02.006  |2 doi 
035 |a (DE-627)1590308468 
035 |a (DE-576)520308468 
035 |a (DE-599)BSZ520308468 
035 |a (OCoLC)1341041428 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
245 1 0 |a Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft  |b early and 2 year results from a European Multicentre Registry  |c D. Böckler, J. Brunkwall, P.R. Taylor, N. Mangialardi, J. Hüsing, T. Larzon, Alexander Hyhlik-Dürr, Michael Gawenda, Rachel Clough, Sonja Ronchey, Lena Örman, on behalf of the CTAG registry investigators 
264 1 |c 20 April 2016 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 14.03.2019 
500 |a Weitere 5 Mitarbeiter bei PDF nicht aufgeführt, nur 6 Verfasser 
520 |a Objective: To assess safety, effectiveness and clinical outcome of the conformable thoracic aortic endograft (CTAG) in the treatment of aortic arch pathologies. Methods: Between October 2009 and December 2010, 100 consecutive patients (65 men; mean age 65 years) with aortic arch pathologies were treated with the CTAG device in five European centres. Indications were thoracic aortic aneurysm (n = 57), Type B dissection (n = 24), intramural haematoma (n = 4), penetrating aortic ulcer (n = 9), and traumatic transection (n = 6). Emergency procedures were performed in 33%. The proximal landing zone (LZ) was LZ 0 in 7%, LZ 1 in14%, LZ 2 in 43%, and LZ 3 in 36%. Data were collected prospectively and analysed for technical and clinical success. Conformability and deployment accuracy were analysed on intra-operative angiography and post-operative computed tomography. Mean follow up was 24 ± 19 months (range, 0.3-36 months). Results: The 30 day, 1 and 2 year survival rates were 90%, 81%, and 74% respectively. The 2 year survival was 80% in the elective and 62% in the emergency groups (p = .20). The major 30 day complication rate was 34%: primary Type Ia endoleak affected 1%, retrograde dissection in 1%, and the paraplegia and stroke rates at 30 days were 4% and 11%. Age > 70 years was an independent predictor for mortality and complications. The primary technical success rate was 92%; device deployment was successful in 100% and accurate in 99%. Conformability to the aortic arch was achieved in 95%. Conclusion: The CTAG stent graft shows high deployment accuracy, good conformability, and clinical effectiveness in the treatment of aortic arch pathologies. However, thoracic endovascular aortic repair in the arch is associated with a relatively high stroke rate. Further studies with more patients and longer follow up are needed to evaluate the long-term results. 
650 4 |a Aneurysm 
650 4 |a Aorta 
650 4 |a Arch 
650 4 |a Stentgraft 
650 4 |a Stroke 
650 4 |a TEVAR 
700 1 |a Hyhlik-Dürr, Alexander  |d 1967-  |e VerfasserIn  |0 (DE-588)123900972  |0 (DE-627)706467248  |0 (DE-576)185933637  |4 aut 
773 0 8 |i Enthalten in  |t European journal of vascular and endovascular surgery  |d New York, NY : Elsevier, 1995  |g 51(2016), 6, Seite 791-800  |h Online-Ressource  |w (DE-627)320444872  |w (DE-600)2005354-X  |w (DE-576)104558539  |x 1532-2165  |7 nnas  |a Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft early and 2 year results from a European Multicentre Registry 
773 1 8 |g volume:51  |g year:2016  |g number:6  |g pages:791-800  |g extent:10  |a Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft early and 2 year results from a European Multicentre Registry 
856 4 0 |u http://dx.doi.org/10.1016/j.ejvs.2016.02.006  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1078588416000988  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190314 
993 |a Article 
994 |a 2016 
998 |g 123900972  |a Hyhlik-Dürr, Alexander  |m 123900972:Hyhlik-Dürr, Alexander  |d 910000  |d 910200  |e 910000PH123900972  |e 910200PH123900972  |k 0/910000/  |k 1/910000/910200/  |p 7 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1590308468  |e 3061238794 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft","title":"Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft","subtitle":"early and 2 year results from a European Multicentre Registry"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1016/j.ejvs.2016.02.006"],"eki":["1590308468"]},"physDesc":[{"extent":"10 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2005354-X"],"issn":["1532-2165"],"eki":["320444872"]},"title":[{"title_sort":"European journal of vascular and endovascular surgery","title":"European journal of vascular and endovascular surgery"}],"origin":[{"dateIssuedDisp":"1995-","publisher":"Elsevier ; Saunders ; Harcourt Publ.","publisherPlace":"New York, NY ; [Erscheinungsort nicht ermittelbar] ; London","dateIssuedKey":"1995"}],"recId":"320444872","disp":"Thoracic endovascular aortic repair of aortic arch pathologies with the conformable thoracic aortic graft early and 2 year results from a European Multicentre RegistryEuropean journal of vascular and endovascular surgery","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"EJVES"}],"part":{"year":"2016","volume":"51","text":"51(2016), 6, Seite 791-800","pages":"791-800","extent":"10","issue":"6"},"language":["eng"],"note":["Gesehen am 05.02.20"],"pubHistory":["9.1995 -"]}],"origin":[{"dateIssuedDisp":"20 April 2016","dateIssuedKey":"2016"}],"language":["eng"],"name":{"displayForm":["D. Böckler, J. Brunkwall, P.R. Taylor, N. Mangialardi, J. Hüsing, T. Larzon, Alexander Hyhlik-Dürr, Michael Gawenda, Rachel Clough, Sonja Ronchey, Lena Örman, on behalf of the CTAG registry investigators"]},"person":[{"given":"Dittmar","display":"Böckler, Dittmar","role":"aut","family":"Böckler"},{"given":"Alexander","display":"Hyhlik-Dürr, Alexander","role":"aut","family":"Hyhlik-Dürr"}],"recId":"1590308468","note":["Gesehen am 14.03.2019","Weitere 5 Mitarbeiter bei PDF nicht aufgeführt, nur 6 Verfasser"]} 
SRT |a BOECKLERDITHORACICEN2020