Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients

Background: High-dose radiotherapy of lung cancer is challenging. Tumors may move by up to 2 cm in craniocaudal and anteroposterior directions as a function of breathing cycle. Tumor displacement increases with treatment time, which consequentially increases the treatment uncertainty. Objective: Thi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Simeonova-Chergou, Anna (VerfasserIn) , Jahnke, Anika (VerfasserIn) , Siebenlist, Kerstin (VerfasserIn) , Stieler, Florian (VerfasserIn) , Mai, Sabine (VerfasserIn) , Boda-Heggemann, Judit (VerfasserIn) , Wenz, Frederik (VerfasserIn) , Lohr, Frank (VerfasserIn) , Jahnke, Lennart (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 15 January 2016
In: Strahlentherapie und Onkologie
Year: 2016, Jahrgang: 192, Heft: 3, Pages: 166-173
ISSN:1439-099X
DOI:10.1007/s00066-015-0934-z
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s00066-015-0934-z
Verlag, Volltext: https://doi.org/10.1007/s00066-015-0934-z
Volltext
Verfasserangaben:Anna Simeonova-Chergou, Anika Jahnke, Kerstin Siebenlist, Florian Stieler, Sabine Mai, Judit Boda-Heggemann, Frederik Wenz, Frank Lohr, Lennart Jahnke

MARC

LEADER 00000caa a2200000 c 4500
001 1590359348
003 DE-627
005 20220815123530.0
007 cr uuu---uuuuu
008 190315s2016 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00066-015-0934-z  |2 doi 
035 |a (DE-627)1590359348 
035 |a (DE-576)520359348 
035 |a (DE-599)BSZ520359348 
035 |a (OCoLC)1341041467 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Simeonova-Chergou, Anna  |d 1980-  |e VerfasserIn  |0 (DE-588)1022879944  |0 (DE-627)71732477X  |0 (DE-576)363041532  |4 aut 
245 1 0 |a Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients  |c Anna Simeonova-Chergou, Anika Jahnke, Kerstin Siebenlist, Florian Stieler, Sabine Mai, Judit Boda-Heggemann, Frederik Wenz, Frank Lohr, Lennart Jahnke 
264 1 |c 15 January 2016 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.03.2019 
520 |a Background: High-dose radiotherapy of lung cancer is challenging. Tumors may move by up to 2 cm in craniocaudal and anteroposterior directions as a function of breathing cycle. Tumor displacement increases with treatment time, which consequentially increases the treatment uncertainty. Objective: This study analyzed whether automatically gated cone-beam-CT (CBCT)-controlled intensity modulated fast deep inspiration breath hold (DIBH) stereotactic body radiation therapy (SBRT) in flattening filter free (FFF) technique and normofractionated lung DIBH intensity-modulated radiotherapy (IMRT)/volumetric-modulated arc therapy (VMAT) treatments delivered with a flattening filter can be applied with sufficient accuracy within a clinically acceptable timeslot. Materials and methods: Plans of 34 patients with lung tumors were analyzed. Of these patients, 17 received computer-controlled fast DIBH SBRT with a dose of 60 Gy (5 fractions of 12 Gy or 12 fractions of 5 Gy) in an FFF VMAT technique (FFF-SBRT) every other day and 17 received conventional VMAT with a flattening filter (conv-VMAT) and 2-Gy daily fractional doses (cumulative dose 50-70 Gy).ResultsFFF-SBRT plans required more monitor units (MU) than conv-VMAT plans (2956.6 ± 885.3 MU for 12 Gy/fraction and 1148.7 ± 289.2 MU for 5 Gy/fraction vs. 608.4 ± 157.5 MU for 2 Gy/fraction). Total treatment and net beam-on times were shorter for FFF-SBRT plans than conv-VMAT plans (268.0 ± 74.4 s vs. 330.2 ± 93.6 s and 85.8 ± 25.3 s vs. 117.2 ± 29.6 s, respectively). Total slot time was 13.0 min for FFF-SBRT and 14.0 min for conv-VMAT. All modalities could be delivered accurately despite multiple beam-on/-off cycles and were robust against multiple interruptions. Conclusion: Automatically gated CBCT-controlled fast DIBH SBRT in VMAT FFF technique and normofractionated lung DIBH VMAT can be applied with a low number of breath-holds in a short timeslot, with excellent dosimetric accuracy. In clinical routine, these approaches combine optimally reduced lung tissue irradiation with maximal delivery precision for patients with small and larger lung tumors. 
650 4 |a Atemanhalt 
650 4 |a Atmung 
650 4 |a Bildgebung 
650 4 |a Breathing 
650 4 |a Cone-beam computed tomography 
650 4 |a Cone-Beam-Computertomographie 
650 4 |a Imaging 
650 4 |a Linear accelerators 
650 4 |a Linearbeschleuniger 
650 4 |a Lungenkarzinom 
650 4 |a Qualitätssicherung 
650 4 |a Quality assurance 
700 1 |a Jahnke, Anika  |d 1983-  |e VerfasserIn  |0 (DE-588)1069149470  |0 (DE-627)821383108  |0 (DE-576)42844461X  |4 aut 
700 1 |a Siebenlist, Kerstin  |e VerfasserIn  |0 (DE-588)1050869559  |0 (DE-627)785231005  |0 (DE-576)405268092  |4 aut 
700 1 |a Stieler, Florian  |d 1979-  |e VerfasserIn  |0 (DE-588)1018888055  |0 (DE-627)683440187  |0 (DE-576)354555626  |4 aut 
700 1 |a Mai, Sabine  |d 1964-  |e VerfasserIn  |0 (DE-588)1048197883  |0 (DE-627)779968042  |0 (DE-576)402013913  |4 aut 
700 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
700 1 |a Lohr, Frank  |e VerfasserIn  |0 (DE-588)1025307194  |0 (DE-627)72201967X  |0 (DE-576)37018694X  |4 aut 
700 1 |a Jahnke, Lennart  |e VerfasserIn  |0 (DE-588)1029119066  |0 (DE-627)732701805  |0 (DE-576)376584653  |4 aut 
773 0 8 |i Enthalten in  |t Strahlentherapie und Onkologie  |d Berlin : Springer Medizin, 1997  |g 192(2016), 3, Seite 166-173  |h Online-Ressource  |w (DE-627)312407866  |w (DE-600)2003907-4  |w (DE-576)090884809  |x 1439-099X  |7 nnas  |a Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients 
773 1 8 |g volume:192  |g year:2016  |g number:3  |g pages:166-173  |g extent:8  |a Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients 
856 4 0 |u http://dx.doi.org/10.1007/s00066-015-0934-z  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1007/s00066-015-0934-z  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190315 
993 |a Article 
994 |a 2016 
998 |g 1029119066  |a Jahnke, Lennart  |m 1029119066:Jahnke, Lennart  |d 60000  |d 63000  |e 60000PJ1029119066  |e 63000PJ1029119066  |k 0/60000/  |k 1/60000/63000/  |p 9  |y j 
998 |g 1025307194  |a Lohr, Frank  |m 1025307194:Lohr, Frank  |d 60000  |d 63000  |e 60000PL1025307194  |e 63000PL1025307194  |k 0/60000/  |k 1/60000/63000/  |p 8 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |e 60000PW113310390  |e 63000PW113310390  |k 0/60000/  |k 1/60000/63000/  |p 7 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |d 63000  |e 60000PB1029853436  |e 63000PB1029853436  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 1048197883  |a Mai, Sabine  |m 1048197883:Mai, Sabine  |d 60000  |d 63000  |e 60000PM1048197883  |e 63000PM1048197883  |k 0/60000/  |k 1/60000/63000/  |p 5 
998 |g 1018888055  |a Stieler, Florian  |m 1018888055:Stieler, Florian  |d 60000  |d 63000  |e 60000PS1018888055  |e 63000PS1018888055  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1050869559  |a Siebenlist, Kerstin  |m 1050869559:Siebenlist, Kerstin  |d 60000  |d 63000  |e 60000PS1050869559  |e 63000PS1050869559  |k 0/60000/  |k 1/60000/63000/  |p 3 
998 |g 1069149470  |a Jahnke, Anika  |m 1069149470:Jahnke, Anika  |d 60000  |d 63000  |e 60000PJ1069149470  |e 63000PJ1069149470  |k 0/60000/  |k 1/60000/63000/  |p 2 
998 |g 1022879944  |a Simeonova-Chergou, Anna  |m 1022879944:Simeonova-Chergou, Anna  |d 60000  |d 63000  |e 60000PS1022879944  |e 63000PS1022879944  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1590359348  |e 3061401091 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","given":"Anna","family":"Simeonova-Chergou","display":"Simeonova-Chergou, Anna"},{"given":"Anika","role":"aut","family":"Jahnke","display":"Jahnke, Anika"},{"family":"Siebenlist","display":"Siebenlist, Kerstin","given":"Kerstin","role":"aut"},{"role":"aut","given":"Florian","display":"Stieler, Florian","family":"Stieler"},{"given":"Sabine","role":"aut","family":"Mai","display":"Mai, Sabine"},{"role":"aut","given":"Judit","family":"Boda-Heggemann","display":"Boda-Heggemann, Judit"},{"role":"aut","given":"Frederik","display":"Wenz, Frederik","family":"Wenz"},{"role":"aut","given":"Frank","family":"Lohr","display":"Lohr, Frank"},{"family":"Jahnke","display":"Jahnke, Lennart","role":"aut","given":"Lennart"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 15.03.2019"],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"15 January 2016"}],"title":[{"title":"Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients","title_sort":"Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients"}],"id":{"doi":["10.1007/s00066-015-0934-z"],"eki":["1590359348"]},"recId":"1590359348","relHost":[{"part":{"year":"2016","pages":"166-173","issue":"3","text":"192(2016), 3, Seite 166-173","volume":"192","extent":"8"},"language":["ger"],"id":{"eki":["312407866"],"zdb":["2003907-4"],"issn":["1439-099X"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"312407866","type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patientsStrahlentherapie und Onkologie","title":[{"title":"Strahlentherapie und Onkologie","title_sort":"Strahlentherapie und Onkologie","subtitle":"journal of radiation oncology, biology, physics"}],"note":["Gesehen am 13.05.09"],"origin":[{"dateIssuedDisp":"1997-","dateIssuedKey":"1997","publisher":"Springer Medizin ; Urban & Vogel","publisherPlace":"Berlin ; Heidelberg ; [München]"}],"pubHistory":["Nachgewiesen 173.1997 -"]}],"name":{"displayForm":["Anna Simeonova-Chergou, Anika Jahnke, Kerstin Siebenlist, Florian Stieler, Sabine Mai, Judit Boda-Heggemann, Frederik Wenz, Frank Lohr, Lennart Jahnke"]},"physDesc":[{"extent":"8 S."}]} 
SRT |a SIMEONOVACAUTOMATICA1520