Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients
Background: High-dose radiotherapy of lung cancer is challenging. Tumors may move by up to 2 cm in craniocaudal and anteroposterior directions as a function of breathing cycle. Tumor displacement increases with treatment time, which consequentially increases the treatment uncertainty. Objective: Thi...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
15 January 2016
|
| In: |
Strahlentherapie und Onkologie
Year: 2016, Jahrgang: 192, Heft: 3, Pages: 166-173 |
| ISSN: | 1439-099X |
| DOI: | 10.1007/s00066-015-0934-z |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1007/s00066-015-0934-z Verlag, Volltext: https://doi.org/10.1007/s00066-015-0934-z |
| Verfasserangaben: | Anna Simeonova-Chergou, Anika Jahnke, Kerstin Siebenlist, Florian Stieler, Sabine Mai, Judit Boda-Heggemann, Frederik Wenz, Frank Lohr, Lennart Jahnke |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1590359348 | ||
| 003 | DE-627 | ||
| 005 | 20220815123530.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190315s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00066-015-0934-z |2 doi | |
| 035 | |a (DE-627)1590359348 | ||
| 035 | |a (DE-576)520359348 | ||
| 035 | |a (DE-599)BSZ520359348 | ||
| 035 | |a (OCoLC)1341041467 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Simeonova-Chergou, Anna |d 1980- |e VerfasserIn |0 (DE-588)1022879944 |0 (DE-627)71732477X |0 (DE-576)363041532 |4 aut | |
| 245 | 1 | 0 | |a Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients |c Anna Simeonova-Chergou, Anika Jahnke, Kerstin Siebenlist, Florian Stieler, Sabine Mai, Judit Boda-Heggemann, Frederik Wenz, Frank Lohr, Lennart Jahnke |
| 264 | 1 | |c 15 January 2016 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 15.03.2019 | ||
| 520 | |a Background: High-dose radiotherapy of lung cancer is challenging. Tumors may move by up to 2 cm in craniocaudal and anteroposterior directions as a function of breathing cycle. Tumor displacement increases with treatment time, which consequentially increases the treatment uncertainty. Objective: This study analyzed whether automatically gated cone-beam-CT (CBCT)-controlled intensity modulated fast deep inspiration breath hold (DIBH) stereotactic body radiation therapy (SBRT) in flattening filter free (FFF) technique and normofractionated lung DIBH intensity-modulated radiotherapy (IMRT)/volumetric-modulated arc therapy (VMAT) treatments delivered with a flattening filter can be applied with sufficient accuracy within a clinically acceptable timeslot. Materials and methods: Plans of 34 patients with lung tumors were analyzed. Of these patients, 17 received computer-controlled fast DIBH SBRT with a dose of 60 Gy (5 fractions of 12 Gy or 12 fractions of 5 Gy) in an FFF VMAT technique (FFF-SBRT) every other day and 17 received conventional VMAT with a flattening filter (conv-VMAT) and 2-Gy daily fractional doses (cumulative dose 50-70 Gy).ResultsFFF-SBRT plans required more monitor units (MU) than conv-VMAT plans (2956.6 ± 885.3 MU for 12 Gy/fraction and 1148.7 ± 289.2 MU for 5 Gy/fraction vs. 608.4 ± 157.5 MU for 2 Gy/fraction). Total treatment and net beam-on times were shorter for FFF-SBRT plans than conv-VMAT plans (268.0 ± 74.4 s vs. 330.2 ± 93.6 s and 85.8 ± 25.3 s vs. 117.2 ± 29.6 s, respectively). Total slot time was 13.0 min for FFF-SBRT and 14.0 min for conv-VMAT. All modalities could be delivered accurately despite multiple beam-on/-off cycles and were robust against multiple interruptions. Conclusion: Automatically gated CBCT-controlled fast DIBH SBRT in VMAT FFF technique and normofractionated lung DIBH VMAT can be applied with a low number of breath-holds in a short timeslot, with excellent dosimetric accuracy. In clinical routine, these approaches combine optimally reduced lung tissue irradiation with maximal delivery precision for patients with small and larger lung tumors. | ||
| 650 | 4 | |a Atemanhalt | |
| 650 | 4 | |a Atmung | |
| 650 | 4 | |a Bildgebung | |
| 650 | 4 | |a Breathing | |
| 650 | 4 | |a Cone-beam computed tomography | |
| 650 | 4 | |a Cone-Beam-Computertomographie | |
| 650 | 4 | |a Imaging | |
| 650 | 4 | |a Linear accelerators | |
| 650 | 4 | |a Linearbeschleuniger | |
| 650 | 4 | |a Lungenkarzinom | |
| 650 | 4 | |a Qualitätssicherung | |
| 650 | 4 | |a Quality assurance | |
| 700 | 1 | |a Jahnke, Anika |d 1983- |e VerfasserIn |0 (DE-588)1069149470 |0 (DE-627)821383108 |0 (DE-576)42844461X |4 aut | |
| 700 | 1 | |a Siebenlist, Kerstin |e VerfasserIn |0 (DE-588)1050869559 |0 (DE-627)785231005 |0 (DE-576)405268092 |4 aut | |
| 700 | 1 | |a Stieler, Florian |d 1979- |e VerfasserIn |0 (DE-588)1018888055 |0 (DE-627)683440187 |0 (DE-576)354555626 |4 aut | |
| 700 | 1 | |a Mai, Sabine |d 1964- |e VerfasserIn |0 (DE-588)1048197883 |0 (DE-627)779968042 |0 (DE-576)402013913 |4 aut | |
| 700 | 1 | |a Boda-Heggemann, Judit |d 1977- |e VerfasserIn |0 (DE-588)1029853436 |0 (DE-627)734363087 |0 (DE-576)377699411 |4 aut | |
| 700 | 1 | |a Wenz, Frederik |d 1966- |e VerfasserIn |0 (DE-588)113310390 |0 (DE-627)663837766 |0 (DE-576)346656281 |4 aut | |
| 700 | 1 | |a Lohr, Frank |e VerfasserIn |0 (DE-588)1025307194 |0 (DE-627)72201967X |0 (DE-576)37018694X |4 aut | |
| 700 | 1 | |a Jahnke, Lennart |e VerfasserIn |0 (DE-588)1029119066 |0 (DE-627)732701805 |0 (DE-576)376584653 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Strahlentherapie und Onkologie |d Berlin : Springer Medizin, 1997 |g 192(2016), 3, Seite 166-173 |h Online-Ressource |w (DE-627)312407866 |w (DE-600)2003907-4 |w (DE-576)090884809 |x 1439-099X |7 nnas |a Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients |
| 773 | 1 | 8 | |g volume:192 |g year:2016 |g number:3 |g pages:166-173 |g extent:8 |a Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00066-015-0934-z |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00066-015-0934-z |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190315 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 1029119066 |a Jahnke, Lennart |m 1029119066:Jahnke, Lennart |d 60000 |d 63000 |e 60000PJ1029119066 |e 63000PJ1029119066 |k 0/60000/ |k 1/60000/63000/ |p 9 |y j | ||
| 998 | |g 1025307194 |a Lohr, Frank |m 1025307194:Lohr, Frank |d 60000 |d 63000 |e 60000PL1025307194 |e 63000PL1025307194 |k 0/60000/ |k 1/60000/63000/ |p 8 | ||
| 998 | |g 113310390 |a Wenz, Frederik |m 113310390:Wenz, Frederik |d 60000 |d 63000 |e 60000PW113310390 |e 63000PW113310390 |k 0/60000/ |k 1/60000/63000/ |p 7 | ||
| 998 | |g 1029853436 |a Boda-Heggemann, Judit |m 1029853436:Boda-Heggemann, Judit |d 60000 |d 63000 |e 60000PB1029853436 |e 63000PB1029853436 |k 0/60000/ |k 1/60000/63000/ |p 6 | ||
| 998 | |g 1048197883 |a Mai, Sabine |m 1048197883:Mai, Sabine |d 60000 |d 63000 |e 60000PM1048197883 |e 63000PM1048197883 |k 0/60000/ |k 1/60000/63000/ |p 5 | ||
| 998 | |g 1018888055 |a Stieler, Florian |m 1018888055:Stieler, Florian |d 60000 |d 63000 |e 60000PS1018888055 |e 63000PS1018888055 |k 0/60000/ |k 1/60000/63000/ |p 4 | ||
| 998 | |g 1050869559 |a Siebenlist, Kerstin |m 1050869559:Siebenlist, Kerstin |d 60000 |d 63000 |e 60000PS1050869559 |e 63000PS1050869559 |k 0/60000/ |k 1/60000/63000/ |p 3 | ||
| 998 | |g 1069149470 |a Jahnke, Anika |m 1069149470:Jahnke, Anika |d 60000 |d 63000 |e 60000PJ1069149470 |e 63000PJ1069149470 |k 0/60000/ |k 1/60000/63000/ |p 2 | ||
| 998 | |g 1022879944 |a Simeonova-Chergou, Anna |m 1022879944:Simeonova-Chergou, Anna |d 60000 |d 63000 |e 60000PS1022879944 |e 63000PS1022879944 |k 0/60000/ |k 1/60000/63000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1590359348 |e 3061401091 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"role":"aut","given":"Anna","family":"Simeonova-Chergou","display":"Simeonova-Chergou, Anna"},{"given":"Anika","role":"aut","family":"Jahnke","display":"Jahnke, Anika"},{"family":"Siebenlist","display":"Siebenlist, Kerstin","given":"Kerstin","role":"aut"},{"role":"aut","given":"Florian","display":"Stieler, Florian","family":"Stieler"},{"given":"Sabine","role":"aut","family":"Mai","display":"Mai, Sabine"},{"role":"aut","given":"Judit","family":"Boda-Heggemann","display":"Boda-Heggemann, Judit"},{"role":"aut","given":"Frederik","display":"Wenz, Frederik","family":"Wenz"},{"role":"aut","given":"Frank","family":"Lohr","display":"Lohr, Frank"},{"family":"Jahnke","display":"Jahnke, Lennart","role":"aut","given":"Lennart"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 15.03.2019"],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"15 January 2016"}],"title":[{"title":"Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients","title_sort":"Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients"}],"id":{"doi":["10.1007/s00066-015-0934-z"],"eki":["1590359348"]},"recId":"1590359348","relHost":[{"part":{"year":"2016","pages":"166-173","issue":"3","text":"192(2016), 3, Seite 166-173","volume":"192","extent":"8"},"language":["ger"],"id":{"eki":["312407866"],"zdb":["2003907-4"],"issn":["1439-099X"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"312407866","type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patientsStrahlentherapie und Onkologie","title":[{"title":"Strahlentherapie und Onkologie","title_sort":"Strahlentherapie und Onkologie","subtitle":"journal of radiation oncology, biology, physics"}],"note":["Gesehen am 13.05.09"],"origin":[{"dateIssuedDisp":"1997-","dateIssuedKey":"1997","publisher":"Springer Medizin ; Urban & Vogel","publisherPlace":"Berlin ; Heidelberg ; [München]"}],"pubHistory":["Nachgewiesen 173.1997 -"]}],"name":{"displayForm":["Anna Simeonova-Chergou, Anika Jahnke, Kerstin Siebenlist, Florian Stieler, Sabine Mai, Judit Boda-Heggemann, Frederik Wenz, Frank Lohr, Lennart Jahnke"]},"physDesc":[{"extent":"8 S."}]} | ||
| SRT | |a SIMEONOVACAUTOMATICA1520 | ||