Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) Buch/Monographie |
| Sprache: | Englisch |
| Veröffentlicht: |
London
BioMed Central
07 December 2017
|
| DOI: | 10.1186/s12893-017-0329-4 |
| Online-Zugang: | Resolving-System, kostenfrei, Volltext: http://dx.doi.org/10.1186/s12893-017-0329-4 Resolving-System, kostenfrei, Volltext: http://nbn-resolving.de/urn:nbn:de:bsz:16-heidok-243003 |
| Verfasserangaben: | Georgios Polychronidis, Roland Hennes, Cosima Engerer, Phillip Knebel, Daniel Schultze, Thomas Bruckner, Beat P. Müller-Stich and Lars Fischer |
MARC
| LEADER | 00000cam a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1655246208 | ||
| 003 | DE-627 | ||
| 005 | 20230427092812.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180426s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a urn:nbn:de:bsz:16-heidok-243003 |2 urn | |
| 024 | 7 | |a 10.1186/s12893-017-0329-4 |2 doi | |
| 035 | |a (DE-627)1655246208 | ||
| 035 | |a (DE-576)502417293 | ||
| 035 | |a (DE-599)BSZ502417293 | ||
| 035 | |a (OCoLC)1033831539 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 082 | 0 | 4 | |a 570 |a 610 |
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Polychronidis, Georgios |d 1984- |e VerfasserIn |0 (DE-588)1071576984 |0 (DE-627)826052975 |0 (DE-576)433162384 |4 aut | |
| 245 | 1 | 0 | |a Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery |c Georgios Polychronidis, Roland Hennes, Cosima Engerer, Phillip Knebel, Daniel Schultze, Thomas Bruckner, Beat P. Müller-Stich and Lars Fischer |
| 264 | 1 | |a London |b BioMed Central |c 07 December 2017 | |
| 300 | |a 1 Online-Ressource (7 Seiten) | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Aus: BMC Surgery, 17 (2017), Nr. 131. pp. 1-7. ISSN 1471-2482 | ||
| 700 | 1 | |a Hennes, Roland |d 19XX- |e VerfasserIn |0 (DE-588)1066868530 |0 (DE-627)817988661 |0 (DE-576)426254139 |4 aut | |
| 700 | 1 | |a Engerer, Cosima |e VerfasserIn |0 (DE-588)115087743X |0 (DE-627)1011137488 |0 (DE-576)496900757 |4 aut | |
| 700 | 1 | |a Knebel, Phillip |d 1977- |e VerfasserIn |0 (DE-588)131961829 |0 (DE-627)516320114 |0 (DE-576)298863170 |4 aut | |
| 700 | 1 | |a Schultze, Daniel |d 1980- |e VerfasserIn |0 (DE-588)1054785260 |0 (DE-627)792111532 |0 (DE-576)410512958 |4 aut | |
| 700 | 1 | |a Bruckner, Thomas |d 1956- |e VerfasserIn |0 (DE-588)136046215 |0 (DE-627)574429298 |0 (DE-576)300798768 |4 aut | |
| 700 | 1 | |a Müller, Beat P. |d 1971- |e VerfasserIn |0 (DE-588)14066209X |0 (DE-627)70374819X |0 (DE-576)317992287 |4 aut | |
| 700 | 1 | |a Fischer, Lars |d 1971- |e VerfasserIn |0 (DE-588)122982606 |0 (DE-627)706116674 |0 (DE-576)302554661 |4 aut | |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1186/s12893-017-0329-4 |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u http://nbn-resolving.de/urn:nbn:de:bsz:16-heidok-243003 |q application/pdf |x Resolving-System |z kostenfrei |3 Volltext |
| 951 | |a BO | ||
| 992 | |a 20180426 | ||
| 993 | |a Article | ||
| 998 | |g 122982606 |a Fischer, Lars |m 122982606:Fischer, Lars |d 910000 |d 910200 |d 50000 |e 910000PF122982606 |e 910200PF122982606 |e 50000PF122982606 |k 0/910000/ |k 1/910000/910200/ |k 0/50000/ |p 8 |y j | ||
| 998 | |g 14066209X |a Müller, Beat P. |m 14066209X:Müller, Beat P. |d 910000 |d 910200 |e 910000PM14066209X |e 910200PM14066209X |k 0/910000/ |k 1/910000/910200/ |p 7 | ||
| 998 | |g 136046215 |a Bruckner, Thomas |m 136046215:Bruckner, Thomas |d 910000 |d 999701 |e 910000PB136046215 |e 999701PB136046215 |k 0/910000/ |k 1/910000/999701/ |p 6 | ||
| 998 | |g 1054785260 |a Schultze, Daniel |m 1054785260:Schultze, Daniel |d 910000 |d 910200 |e 910000PS1054785260 |e 910200PS1054785260 |k 0/910000/ |k 1/910000/910200/ |p 5 | ||
| 998 | |g 131961829 |a Knebel, Phillip |m 131961829:Knebel, Phillip |d 910000 |d 910200 |e 910000PK131961829 |e 910200PK131961829 |k 0/910000/ |k 1/910000/910200/ |p 4 | ||
| 998 | |g 115087743X |a Engerer, Cosima |m 115087743X:Engerer, Cosima |d 910000 |d 910200 |e 910000PE115087743X |e 910200PE115087743X |k 0/910000/ |k 1/910000/910200/ |p 3 | ||
| 998 | |g 1066868530 |a Hennes, Roland |m 1066868530:Hennes, Roland |d 910000 |d 910200 |e 910000PH1066868530 |e 910200PH1066868530 |k 0/910000/ |k 1/910000/910200/ |p 2 | ||
| 998 | |g 1071576984 |a Polychronidis, Georgios |m 1071576984:Polychronidis, Georgios |d 910000 |d 910200 |e 910000PP1071576984 |e 910200PP1071576984 |k 0/910000/ |k 1/910000/910200/ |p 1 |x j | ||
| 999 | |a KXP-PPN1655246208 |e 3378977213 | ||
| BIB | |a Y | ||
| JSO | |a {"person":[{"given":"Georgios","family":"Polychronidis","display":"Polychronidis, Georgios","role":"aut"},{"display":"Hennes, Roland","family":"Hennes","given":"Roland","role":"aut"},{"role":"aut","family":"Engerer","display":"Engerer, Cosima","given":"Cosima"},{"role":"aut","family":"Knebel","display":"Knebel, Phillip","given":"Phillip"},{"display":"Schultze, Daniel","family":"Schultze","given":"Daniel","role":"aut"},{"role":"aut","given":"Thomas","display":"Bruckner, Thomas","family":"Bruckner"},{"role":"aut","given":"Beat P.","display":"Müller, Beat P.","family":"Müller"},{"given":"Lars","display":"Fischer, Lars","family":"Fischer","role":"aut"}],"title":[{"title_sort":"Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery","title":"Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery"}],"physDesc":[{"extent":"1 Online-Ressource (7 Seiten)"}],"type":{"media":"Online-Ressource","bibl":"book"},"id":{"uri":["urn:nbn:de:bsz:16-heidok-243003"],"doi":["10.1186/s12893-017-0329-4"],"eki":["1655246208"]},"language":["eng"],"origin":[{"dateIssuedDisp":"07 December 2017","publisherPlace":"London","dateIssuedKey":"2017","publisher":"BioMed Central"}],"name":{"displayForm":["Georgios Polychronidis, Roland Hennes, Cosima Engerer, Phillip Knebel, Daniel Schultze, Thomas Bruckner, Beat P. Müller-Stich and Lars Fischer"]},"note":["Aus: BMC Surgery, 17 (2017), Nr. 131. pp. 1-7. ISSN 1471-2482"],"recId":"1655246208"} | ||
| SRT | |a POLYCHRONIUSEOFAHYDR0720 | ||