Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy
Background: The present work aimed to analyze the feasibility of a shuttle-based MRI-guided radiation therapy (MRgRT) in the treatment of pelvic malignancies. Patients and methods: 20 patients with pelvic malignancies were included in this prospective feasibility analysis. Patients underwent daily M...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
18 January 2018
|
| In: |
Strahlentherapie und Onkologie
Year: 2018, Volume: 194, Issue: 5, Pages: 425-434 |
| ISSN: | 1439-099X |
| DOI: | 10.1007/s00066-017-1258-y |
| Online Access: | Verlag, Volltext: https://doi.org/10.1007/s00066-017-1258-y |
| Author Notes: | Tilman Bostel, Asja Pfaffenberger, Stefan Delorme, Constantin Dreher, Gernot Echner, Peter Haering, Clemens Lang, Mona Splinter, Frederik Laun, Marco Müller, Oliver Jäkel, Jürgen Debus, Peter E. Huber, Florian Sterzing, Nils H. Nicolay |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1662848935 | ||
| 003 | DE-627 | ||
| 005 | 20251011155159.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190404s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00066-017-1258-y |2 doi | |
| 035 | |a (DE-627)1662848935 | ||
| 035 | |a (DE-599)KXP1662848935 | ||
| 035 | |a (OCoLC)1341207868 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Bostel, Tilman |d 1978- |e VerfasserIn |0 (DE-588)101379124X |0 (DE-627)664944183 |0 (DE-576)347666809 |4 aut | |
| 245 | 1 | 0 | |a Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy |c Tilman Bostel, Asja Pfaffenberger, Stefan Delorme, Constantin Dreher, Gernot Echner, Peter Haering, Clemens Lang, Mona Splinter, Frederik Laun, Marco Müller, Oliver Jäkel, Jürgen Debus, Peter E. Huber, Florian Sterzing, Nils H. Nicolay |
| 264 | 1 | |c 18 January 2018 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 04.04.2019 | ||
| 520 | |a Background: The present work aimed to analyze the feasibility of a shuttle-based MRI-guided radiation therapy (MRgRT) in the treatment of pelvic malignancies. Patients and methods: 20 patients with pelvic malignancies were included in this prospective feasibility analysis. Patients underwent daily MRI in treatment position prior to radiotherapy at the German Cancer Research Center. Positional inaccuracies, time and patient compliance were assessed for the application of off-line MRgRT.ResultsIn 78% of applied radiation fractions, MR imaging for position verification could be performed without problems. Additionally, treatment-related side effects and reduced patient compliance were only responsible for omission of MRI in 9% of radiation fractions. The study workflow took a median time of 61 min (range 47–99 min); duration for radiotherapy alone was 13 min (range 7–26 min). Patient positioning, MR imaging and CT imaging including patient repositioning and the shuttle transfer required median times of 10 min (range 7–14 min), 26 min (range 15–60 min), 5 min (range 3–8 min) and 8 min (range 2–36 min), respectively.To assess feasibility of shuttle-based MRgRT, the reference point coordinates for the x, y and z axis were determined for the MR images and CT obtained prior to the first treatment fraction and correlated with the coordinates of the planning CT. In our dataset, the median positional difference between MR imaging and CT-based imaging based on fiducial matching between MR and CT imaging was equal to or less than 2 mm in all spatial directions. The limited space in the MR scanner influenced patient selection, as the bore of the scanner had to accommodate the immobilization device and the constructed stereotactic frame. Therefore, obese, extremely muscular or very tall patients could not be included in this trial in addition to patients for whom exposure to MRI was generally judged inappropriate. Conclusion: This trial demonstrated for the first time the feasibility and patient compliance of a shuttle-based off-line approach to MRgRT of pelvic malignancies. | ||
| 650 | 4 | |a MR-geführte Radiotherapie | |
| 650 | 4 | |a MRgRT | |
| 650 | 4 | |a MRI | |
| 650 | 4 | |a MRT | |
| 650 | 4 | |a Radiotherapie | |
| 650 | 4 | |a Radiotherapy | |
| 650 | 4 | |a Shuttle | |
| 700 | 1 | |a Debus, Jürgen |d 1964- |e VerfasserIn |0 (DE-588)1022671421 |0 (DE-627)717025780 |0 (DE-576)365774944 |4 aut | |
| 700 | 1 | |a Huber, Peter E. |d 1965- |e VerfasserIn |0 (DE-588)1074678869 |0 (DE-627)832350109 |0 (DE-576)442767803 |4 aut | |
| 700 | 1 | |a Sterzing, Florian |d 1979- |e VerfasserIn |0 (DE-588)130141488 |0 (DE-627)492502722 |0 (DE-576)298021781 |4 aut | |
| 700 | 1 | |a Nicolay, Nils |e VerfasserIn |0 (DE-588)136200834 |0 (DE-627)694181277 |0 (DE-576)279367880 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Strahlentherapie und Onkologie |d Berlin : Springer Medizin, 1997 |g 194(2018), 5, Seite 425-434 |h Online-Ressource |w (DE-627)312407866 |w (DE-600)2003907-4 |w (DE-576)090884809 |x 1439-099X |7 nnas |a Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy |
| 773 | 1 | 8 | |g volume:194 |g year:2018 |g number:5 |g pages:425-434 |g extent:10 |a Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00066-017-1258-y |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190404 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 136200834 |a Nicolay, Nils |m 136200834:Nicolay, Nils |d 910000 |d 911400 |e 910000PN136200834 |e 911400PN136200834 |k 0/910000/ |k 1/910000/911400/ |p 15 |y j | ||
| 998 | |g 130141488 |a Sterzing, Florian |m 130141488:Sterzing, Florian |d 910000 |d 911400 |e 910000PS130141488 |e 911400PS130141488 |k 0/910000/ |k 1/910000/911400/ |p 14 | ||
| 998 | |g 1074678869 |a Huber, Peter E. |m 1074678869:Huber, Peter E. |d 50000 |e 50000PH1074678869 |k 0/50000/ |p 13 | ||
| 998 | |g 1022671421 |a Debus, Jürgen |m 1022671421:Debus, Jürgen |d 910000 |d 911400 |e 910000PD1022671421 |e 911400PD1022671421 |k 0/910000/ |k 1/910000/911400/ |p 12 | ||
| 998 | |g 101379124X |a Bostel, Tilman |m 101379124X:Bostel, Tilman |d 910000 |d 911400 |e 910000PB101379124X |e 911400PB101379124X |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1662848935 |e 3418162444 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"family":"Bostel","display":"Bostel, Tilman","role":"aut","given":"Tilman"},{"family":"Debus","display":"Debus, Jürgen","given":"Jürgen","role":"aut"},{"display":"Huber, Peter E.","role":"aut","given":"Peter E.","family":"Huber"},{"display":"Sterzing, Florian","given":"Florian","role":"aut","family":"Sterzing"},{"family":"Nicolay","given":"Nils","role":"aut","display":"Nicolay, Nils"}],"name":{"displayForm":["Tilman Bostel, Asja Pfaffenberger, Stefan Delorme, Constantin Dreher, Gernot Echner, Peter Haering, Clemens Lang, Mona Splinter, Frederik Laun, Marco Müller, Oliver Jäkel, Jürgen Debus, Peter E. Huber, Florian Sterzing, Nils H. Nicolay"]},"note":["Gesehen am 04.04.2019"],"relHost":[{"pubHistory":["Nachgewiesen 173.1997 -"],"language":["ger"],"part":{"extent":"10","pages":"425-434","issue":"5","year":"2018","text":"194(2018), 5, Seite 425-434","volume":"194"},"title":[{"subtitle":"journal of radiation oncology, biology, physics","title":"Strahlentherapie und Onkologie","title_sort":"Strahlentherapie und Onkologie"}],"note":["Gesehen am 13.05.09"],"physDesc":[{"extent":"Online-Ressource"}],"disp":"Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapyStrahlentherapie und Onkologie","id":{"eki":["312407866"],"issn":["1439-099X"],"zdb":["2003907-4"]},"origin":[{"dateIssuedKey":"1997","publisher":"Springer Medizin ; Urban & Vogel","dateIssuedDisp":"1997-","publisherPlace":"Berlin ; Heidelberg ; [München]"}],"recId":"312407866","type":{"media":"Online-Ressource","bibl":"periodical"}}],"id":{"doi":["10.1007/s00066-017-1258-y"],"eki":["1662848935"]},"physDesc":[{"extent":"10 S."}],"recId":"1662848935","origin":[{"dateIssuedDisp":"18 January 2018","dateIssuedKey":"2018"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"title":"Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy","title_sort":"Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy"}]} | ||
| SRT | |a BOSTELTILMPROSPECTIV1820 | ||