Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section

Purpose: To evaluate the efficacy of inducing labor using a double-balloon catheter and vaginal prostaglandin E2 (PGE2) sequentially, in comparison with vaginal PGE2 alone after previous cesarean section. Methods: A total of 264 pregnant women with previous cesarean section undergoing labor inductio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kehl, Sven (VerfasserIn) , Weiß, Christel (VerfasserIn) , Sütterlin, Marc (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2016
In: Archives of gynecology and obstetrics
Year: 2015, Jahrgang: 293, Heft: 4, Pages: 757-765
ISSN:1432-0711
DOI:10.1007/s00404-015-3907-7
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s00404-015-3907-7
Volltext
Verfasserangaben:Sven Kehl, Christel Weiss, Michael Wamsler, Jana Beyer, Ulf Dammer, Jutta Heimrich, Florian Faschingbauer, Marc Sütterlin, Matthias W. Beckmann, Ekkehard Schleussner

MARC

LEADER 00000caa a2200000 c 4500
001 1662964242
003 DE-627
005 20220816132203.0
007 cr uuu---uuuuu
008 190408r20162015xx |||||o 00| ||eng c
024 7 |a 10.1007/s00404-015-3907-7  |2 doi 
035 |a (DE-627)1662964242 
035 |a (DE-599)KXP1662964242 
035 |a (OCoLC)1341208024 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kehl, Sven  |d 1978-  |e VerfasserIn  |0 (DE-588)130859184  |0 (DE-627)506776980  |0 (DE-576)250757486  |4 aut 
245 1 0 |a Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section  |c Sven Kehl, Christel Weiss, Michael Wamsler, Jana Beyer, Ulf Dammer, Jutta Heimrich, Florian Faschingbauer, Marc Sütterlin, Matthias W. Beckmann, Ekkehard Schleussner 
264 1 |c 2016 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.04.2019 
500 |a Published online: 5 October 2015 
520 |a Purpose: To evaluate the efficacy of inducing labor using a double-balloon catheter and vaginal prostaglandin E2 (PGE2) sequentially, in comparison with vaginal PGE2 alone after previous cesarean section. Methods: A total of 264 pregnant women with previous cesarean section undergoing labor induction at term were included in this prospective multicentre cohort study. Induction of labor was performed either by vaginal PGE2 gel or double-balloon catheter followed by vaginal PGE2. The primary outcome measure was the cesarean section rate. Results: The cesarean section rate was 37 % without any statistically significant difference between the two groups (PGE2: n = 41, 37 % vs. balloon catheter/PGE2: n = 41, 42 %; P = 0.438). The median (range) number of applications of PGE2 [2 (1-10) versus 1 (0-8), P < 0.001] and the total amount of PGE2 used in median (range) mg [2 (1-15) vs. 1 (0-14), P = 0.001] was less in the balloon catheter/PGE2 group. Factors significantly increasing risk for cesarean section were “no previous vaginal delivery” (OR 5.391; CI 2.671-10.882) and “no oxytocin augmentation during childbirth” (OR 2.119; CI 1.215-3.695). Conclusions: The sequential application of double-balloon catheter and vaginal PGE2 is as effective as the sole use of vaginal PGE2 with less applications and total amount of PGE2. 
534 |c 2015 
650 4 |a Dinoprostone 
650 4 |a Double-balloon catheter 
650 4 |a Induction of labor 
650 4 |a Previous cesarean section 
650 4 |a Prostaglandin E2 
650 4 |a Scarred uterus 
700 1 |a Weiß, Christel  |d 1958-  |e VerfasserIn  |0 (DE-588)123287707  |0 (DE-627)082463417  |0 (DE-576)168356104  |4 aut 
700 1 |a Sütterlin, Marc  |d 1967-  |e VerfasserIn  |0 (DE-588)102644067X  |0 (DE-627)72673389X  |0 (DE-576)371782651  |4 aut 
773 0 8 |i Enthalten in  |t Archives of gynecology and obstetrics  |d Berlin : Springer, 1987  |g 293(2016), 4, Seite 757-765  |h Online-Ressource  |w (DE-627)253390060  |w (DE-600)1458450-5  |w (DE-576)072283270  |x 1432-0711  |7 nnas  |a Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section 
773 1 8 |g volume:293  |g year:2016  |g number:4  |g pages:757-765  |g extent:9  |a Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section 
856 4 0 |u https://doi.org/10.1007/s00404-015-3907-7  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20190408 
993 |a Article 
994 |a 2016 
998 |g 102644067X  |a Sütterlin, Marc  |m 102644067X:Sütterlin, Marc  |d 60000  |d 61300  |e 60000PS102644067X  |e 61300PS102644067X  |k 0/60000/  |k 1/60000/61300/  |p 8 
998 |g 123287707  |a Weiß, Christel  |m 123287707:Weiß, Christel  |d 60000  |d 60200  |d 60250  |e 60000PW123287707  |e 60200PW123287707  |e 60250PW123287707  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |p 2 
998 |g 130859184  |a Kehl, Sven  |m 130859184:Kehl, Sven  |d 60000  |d 61300  |e 60000PK130859184  |e 61300PK130859184  |k 0/60000/  |k 1/60000/61300/  |p 1  |x j 
999 |a KXP-PPN1662964242  |e 3421024553 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1007/s00404-015-3907-7"],"eki":["1662964242"]},"physDesc":[{"extent":"9 S."}],"title":[{"title_sort":"Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section","title":"Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section"}],"person":[{"role":"aut","given":"Sven","display":"Kehl, Sven","family":"Kehl"},{"role":"aut","display":"Weiß, Christel","given":"Christel","family":"Weiß"},{"family":"Sütterlin","role":"aut","given":"Marc","display":"Sütterlin, Marc"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"name":{"displayForm":["Sven Kehl, Christel Weiss, Michael Wamsler, Jana Beyer, Ulf Dammer, Jutta Heimrich, Florian Faschingbauer, Marc Sütterlin, Matthias W. Beckmann, Ekkehard Schleussner"]},"language":["eng"],"relHost":[{"name":{"displayForm":["GG, Deutsche Gesellschaft für Gynäkologie und Geburtshilfe"]},"language":["eng"],"id":{"eki":["253390060"],"zdb":["1458450-5"],"issn":["1432-0711"]},"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"1987","publisher":"Springer","dateIssuedDisp":"1987-"}],"note":["Gesehen am 10.07.25","Fortsetzung der Druck-Ausgabe"],"pubHistory":["Volume 241, issue 1 (March 1987)-"],"recId":"253390060","type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title_sort":"Archives of gynecology and obstetrics","title":"Archives of gynecology and obstetrics"}],"part":{"text":"293(2016), 4, Seite 757-765","pages":"757-765","year":"2016","issue":"4","extent":"9","volume":"293"},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean sectionArchives of gynecology and obstetrics","titleAlt":[{"title":"Gynecology and obstetrics"}]}],"recId":"1662964242","note":["Gesehen am 08.04.2019","Published online: 5 October 2015"],"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}]} 
SRT |a KEHLSVENWEDOUBLEBALL2016