Kantenfilter: Medizinische Indikation und klinischer Einsatz = Edge filters : medical indications and clinical application
Edge filters are used in aphakic eyes as a substitute of the natural cut-off filter of the intact eye or in other causes of a lack of light absorption in the eye itself. Furthermore, they can remedy light adaptation disturbances, especially in hereditary retinal diseases and retinal dystrophy. They...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article (Journal) |
| Language: | German English |
| Published: |
9. April 2018
|
| In: |
Der Ophthalmologe
Year: 2018, Volume: 115, Issue: 11, Pages: 916-921 |
| ISSN: | 1433-0423 |
| DOI: | 10.1007/s00347-018-0691-3 |
| Online Access: | Verlag, Volltext: https://doi.org/10.1007/s00347-018-0691-3 |
| Author Notes: | K. Rohrschneider, M. Bach |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1663044309 | ||
| 003 | DE-627 | ||
| 005 | 20230426154302.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190410s2018 xx |||||o 00| ||ger c | ||
| 024 | 7 | |a 10.1007/s00347-018-0691-3 |2 doi | |
| 035 | |a (DE-627)1663044309 | ||
| 035 | |a (DE-599)KXP1663044309 | ||
| 035 | |a (OCoLC)1341208178 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a ger |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rohrschneider, Klaus |d 1961- |e VerfasserIn |0 (DE-588)132834669 |0 (DE-627)52771433X |0 (DE-576)299447030 |4 aut | |
| 245 | 1 | 0 | |a Kantenfilter |b Medizinische Indikation und klinischer Einsatz = Edge filters : medical indications and clinical application |c K. Rohrschneider, M. Bach |
| 246 | 3 | 1 | |a Edge filters |b medical indications and clinical application |
| 264 | 1 | |c 9. April 2018 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 10.04.2019 | ||
| 520 | |a Edge filters are used in aphakic eyes as a substitute of the natural cut-off filter of the intact eye or in other causes of a lack of light absorption in the eye itself. Furthermore, they can remedy light adaptation disturbances, especially in hereditary retinal diseases and retinal dystrophy. They enhance contrast and reduce glare. In order to choose an adequate cut-off filter it is necessary to let the participants test various filters before prescription. Because of the (absolute) absorption of blue light, cut-off filters normally lead to a loss of ability to drive. | ||
| 650 | 4 | |a Achromatopsia | |
| 650 | 4 | |a Achromatopsie | |
| 650 | 4 | |a Aphakia | |
| 650 | 4 | |a Aphakie | |
| 650 | 4 | |a Blauzapfenmonochromasie | |
| 650 | 4 | |a Blue cone monochromacy | |
| 650 | 4 | |a Cut-off filter (edge filter) | |
| 650 | 4 | |a Driving ability | |
| 650 | 4 | |a Kantenfilter | |
| 650 | 4 | |a Kraftfahreignung | |
| 650 | 4 | |a Netzhautdystrophie | |
| 650 | 4 | |a Retinal dystrophy | |
| 700 | 1 | |a Bach, Michael |d 1950- |e VerfasserIn |0 (DE-588)1079313974 |0 (DE-627)842321640 |0 (DE-576)452368847 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Der Ophthalmologe |d Berlin : Springer, 1996 |g 115(2018), 11, Seite 916-921 |h Online-Ressource |w (DE-627)254638589 |w (DE-600)1462970-7 |w (DE-576)074531549 |x 1433-0423 |7 nnas |a Kantenfilter Medizinische Indikation und klinischer Einsatz = Edge filters : medical indications and clinical application |
| 773 | 1 | 8 | |g volume:115 |g year:2018 |g number:11 |g pages:916-921 |g extent:6 |a Kantenfilter Medizinische Indikation und klinischer Einsatz = Edge filters : medical indications and clinical application |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00347-018-0691-3 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190410 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 132834669 |a Rohrschneider, Klaus |m 132834669:Rohrschneider, Klaus |d 910000 |d 910900 |e 910000PR132834669 |e 910900PR132834669 |k 0/910000/ |k 1/910000/910900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1663044309 |e 3421208786 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"titleTranslated":[{"translated":"Edge filters"}],"note":["Gesehen am 10.04.2019"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1663044309","language":["ger","eng"],"title":[{"title_sort":"Kantenfilter","subtitle":"Medizinische Indikation und klinischer Einsatz = Edge filters : medical indications and clinical application","title":"Kantenfilter"}],"person":[{"given":"Klaus","family":"Rohrschneider","role":"aut","roleDisplay":"VerfasserIn","display":"Rohrschneider, Klaus"},{"display":"Bach, Michael","roleDisplay":"VerfasserIn","role":"aut","family":"Bach","given":"Michael"}],"physDesc":[{"extent":"6 S."}],"relHost":[{"origin":[{"dateIssuedDisp":"[1996-2022]","publisher":"Springer ; Springer","publisherPlace":"Berlin ; Heidelberg ; Berlin ; Heidelberg ; New York, NY"}],"id":{"issn":["1433-0423"],"zdb":["1462970-7"],"eki":["254638589"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Ophthalmologe","subtitle":"Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","title":"Der Ophthalmologe"}],"pubHistory":["Nachgewiesen 93.1996,5 - volume 119, issue 5 (May 2022)"],"part":{"extent":"6","volume":"115","text":"115(2018), 11, Seite 916-921","issue":"11","pages":"916-921","year":"2018"},"titleAlt":[{"title":"Publikationsorgan von: Deutsche Ophthalmologische Gesellschaft"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Kantenfilter Medizinische Indikation und klinischer Einsatz = Edge filters : medical indications and clinical applicationDer Ophthalmologe","note":["Gesehen am 27.07.2022","Teils ungezählte Beil.: Supplement"],"language":["ger"],"recId":"254638589"}],"origin":[{"dateIssuedDisp":"9. April 2018","dateIssuedKey":"2018"}],"id":{"eki":["1663044309"],"doi":["10.1007/s00347-018-0691-3"]},"name":{"displayForm":["K. Rohrschneider, M. Bach"]}} | ||
| SRT | |a ROHRSCHNEIKANTENFILT9201 | ||