Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms
Objectives: To assess the influence of image noise on computed tomography (CT) perfusion studies, CT perfusion software algorithms were evaluated for susceptibility to image noise and results applied to clinical perfusion studies. Methods: Digital perfusion phantoms were generated using a published...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
11 October 2018
|
| In: |
European radiology
Year: 2018, Jahrgang: 29, Heft: 4, Pages: 2089-2097 |
| ISSN: | 1432-1084 |
| DOI: | 10.1007/s00330-018-5709-3 |
| Online-Zugang: | Verlag, Volltext: https://doi.org/10.1007/s00330-018-5709-3 |
| Verfasserangaben: | Stephan Skornitzke, Jessica Hirsch, Hans-Ulrich Kauczor, Wolfram Stiller |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1663052425 | ||
| 003 | DE-627 | ||
| 005 | 20220816132630.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190410r20192018xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00330-018-5709-3 |2 doi | |
| 035 | |a (DE-627)1663052425 | ||
| 035 | |a (DE-599)KXP1663052425 | ||
| 035 | |a (OCoLC)1341208048 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Skornitzke, Stephan |d 1987- |e VerfasserIn |0 (DE-588)1110072589 |0 (DE-627)864783523 |0 (DE-576)475718267 |4 aut | |
| 245 | 1 | 0 | |a Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms |c Stephan Skornitzke, Jessica Hirsch, Hans-Ulrich Kauczor, Wolfram Stiller |
| 264 | 1 | |c 11 October 2018 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 10.04.2019 | ||
| 520 | |a Objectives: To assess the influence of image noise on computed tomography (CT) perfusion studies, CT perfusion software algorithms were evaluated for susceptibility to image noise and results applied to clinical perfusion studies. Methods: Digital perfusion phantoms were generated using a published deconvolution model to create time-attenuation curves (TACs) for 16 different combinations of blood flow (BF; 30/60/90/120 ml/100 ml/min) and flow extraction product (FEP; 10/20/30/40 ml/100 ml/min) corresponding to values encountered in clinical studies. TACs were distorted with Gaussian noise at 50 different strengths to approximate image noise, performing 200 repetitions for each noise level. A total of 160,000 TACs were evaluated by measuring BF and FEP with CT perfusion software, comparing results for the maximum slope and Patlak models with those obtained with a deconvolution model. To translate results to clinical practice, data of 23 patients from a CT perfusion study were assessed for image noise, and the accuracy of reported CT perfusion measurements was estimated. Results: Perfusion measurements depend on image noise as means and standard deviations of BF and FEP over repetitions increase with increasing image noise, especially for low BF and FEP values. BF measurements derived by deconvolution show larger standard deviations than those performed with the maximum slope model. Image noise in the evaluated CT perfusion study was 26.46 ± 3.52 HU, indicating possible overestimation of BF by up to 85% in a clinical setting. Conclusions: Measurements of perfusion parameters depend heavily upon the magnitude of image noise, which has to be taken into account during selection of acquisition parameters and interpretation of results, e.g., as a quantitative imaging biomarker. Key Points • CT perfusion results depend heavily upon the magnitude of image noise. • Different CT perfusion models react differently to the presence of image noise. • Blood flow may be overestimated by 85% in clinical CT perfusion studies. | ||
| 534 | |c 2018 | ||
| 650 | 4 | |a Artifacts | |
| 650 | 4 | |a imaging | |
| 650 | 4 | |a Perfusion imaging | |
| 650 | 4 | |a Phantoms | |
| 650 | 4 | |a Software | |
| 650 | 4 | |a Tomography | |
| 650 | 4 | |a x-ray computed | |
| 700 | 1 | |a Hirsch, Jessica |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European radiology |d Berlin : Springer, 1991 |g 29(2019), 4, Seite 2089-2097 |h Online-Ressource |w (DE-627)268757526 |w (DE-600)1472718-3 |w (DE-576)103868070 |x 1432-1084 |7 nnas |a Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms |
| 773 | 1 | 8 | |g volume:29 |g year:2019 |g number:4 |g pages:2089-2097 |g extent:9 |a Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00330-018-5709-3 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190410 | ||
| 993 | |a Article | ||
| 994 | |a 2019 | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |e 910000PS105822672X |e 911400PS105822672X |k 0/910000/ |k 1/910000/911400/ |p 4 |y j | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 3 | ||
| 998 | |g 1110072589 |a Skornitzke, Stephan |m 1110072589:Skornitzke, Stephan |d 910000 |d 911400 |e 910000PS1110072589 |e 911400PS1110072589 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1663052425 |e 3421255342 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1663052425","relHost":[{"id":{"issn":["1432-1084","1613-3757"],"eki":["268757526"],"zdb":["1472718-3"]},"language":["eng"],"recId":"268757526","pubHistory":["1.1991 -"],"origin":[{"dateIssuedKey":"1991","publisher":"Springer","dateIssuedDisp":"1991-","publisherPlace":"Berlin ; Heidelberg"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"physDesc":[{"extent":"Online-Ressource"}],"disp":"Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantomsEuropean radiology","part":{"text":"29(2019), 4, Seite 2089-2097","year":"2019","pages":"2089-2097","issue":"4","volume":"29","extent":"9"},"title":[{"title":"European radiology","subtitle":"official organ of the European Association of Radiology","title_sort":"European radiology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"corporate":[{"role":"isb","display":"European Association of Radiology"}]}],"note":["Gesehen am 10.04.2019"],"origin":[{"dateIssuedDisp":"11 October 2018","dateIssuedKey":"2019"}],"person":[{"family":"Skornitzke","role":"aut","display":"Skornitzke, Stephan","given":"Stephan"},{"display":"Hirsch, Jessica","given":"Jessica","role":"aut","family":"Hirsch"},{"family":"Kauczor","display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","role":"aut"},{"role":"aut","given":"Wolfram","display":"Stiller, Wolfram","family":"Stiller"}],"title":[{"title_sort":"Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms","title":"Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms"}],"physDesc":[{"extent":"9 S."}],"id":{"eki":["1663052425"],"doi":["10.1007/s00330-018-5709-3"]},"language":["eng"],"name":{"displayForm":["Stephan Skornitzke, Jessica Hirsch, Hans-Ulrich Kauczor, Wolfram Stiller"]},"type":{"media":"Online-Ressource","bibl":"article-journal"}} | ||
| SRT | |a SKORNITZKEEVALUATION1120 | ||