Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves

Background—Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry.Methods and Results—The...

Full description

Saved in:
Bibliographic Details
Main Authors: Dvir, Danny (Author) , Bekeredjian, Raffi (Author)
Format: Article (Journal)
Language:English
Published: 10 Oct 2012
In: Circulation
Year: 2012, Volume: 126, Issue: 19, Pages: 2335-2344
ISSN:1524-4539
DOI:10.1161/CIRCULATIONAHA.112.104505
Online Access:Verlag, Volltext: https://doi.org/10.1161/CIRCULATIONAHA.112.104505
Verlag, Volltext: https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.112.104505
Get full text
Author Notes:Danny Dvir, John Webb, Stephen Brecker, Sabine Bleiziffer, David Hildick-Smith, Antonio Colombo, Fleur Descoutures, Christian Hengstenberg, Neil E. Moat, Raffi Bekeredjian, Massimo Napodano, Luca Testa, Thierry Lefevre, Victor Guetta, Henrik Nissen, José-María Hernández, David Roy, Rui C. Teles, Amit Segev, Nicolas Dumonteil, Claudia Fiorina, Michael Gotzmann, Didier Tchetche, Mohamed Abdel-Wahab, Federico De Marco, Andreas Baumbach, Jean-Claude Laborde, Ran Kornowski

MARC

LEADER 00000caa a2200000 c 4500
001 1663245096
003 DE-627
005 20220816134355.0
007 cr uuu---uuuuu
008 190415s2012 xx |||||o 00| ||eng c
024 7 |a 10.1161/CIRCULATIONAHA.112.104505  |2 doi 
035 |a (DE-627)1663245096 
035 |a (DE-599)KXP1663245096 
035 |a (OCoLC)1341209588 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Dvir, Danny  |e VerfasserIn  |0 (DE-588)1182740200  |0 (DE-627)1662899149  |4 aut 
245 1 0 |a Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves  |c Danny Dvir, John Webb, Stephen Brecker, Sabine Bleiziffer, David Hildick-Smith, Antonio Colombo, Fleur Descoutures, Christian Hengstenberg, Neil E. Moat, Raffi Bekeredjian, Massimo Napodano, Luca Testa, Thierry Lefevre, Victor Guetta, Henrik Nissen, José-María Hernández, David Roy, Rui C. Teles, Amit Segev, Nicolas Dumonteil, Claudia Fiorina, Michael Gotzmann, Didier Tchetche, Mohamed Abdel-Wahab, Federico De Marco, Andreas Baumbach, Jean-Claude Laborde, Ran Kornowski 
264 1 |c 10 Oct 2012 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.04.2019 
520 |a Background—Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry.Methods and Results—The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients.Conclusions—The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure. 
700 1 |a Bekeredjian, Raffi  |d 1972-  |e VerfasserIn  |0 (DE-588)122088271  |0 (DE-627)705767930  |0 (DE-576)293085781  |4 aut 
773 0 8 |i Enthalten in  |t Circulation  |d Philadelphia, Pa. : Lippincott, Williams & Wilkins, 1950  |g 126(2012), 19, Seite 2335-2344  |h Online-Ressource  |w (DE-627)265784670  |w (DE-600)1466401-X  |w (DE-576)074891189  |x 1524-4539  |7 nnas  |a Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves 
773 1 8 |g volume:126  |g year:2012  |g number:19  |g pages:2335-2344  |g extent:10  |a Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves 
856 4 0 |u https://doi.org/10.1161/CIRCULATIONAHA.112.104505  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.112.104505  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20190415 
993 |a Article 
994 |a 2012 
998 |g 122088271  |a Bekeredjian, Raffi  |m 122088271:Bekeredjian, Raffi  |d 910000  |d 910100  |e 910000PB122088271  |e 910100PB122088271  |k 0/910000/  |k 1/910000/910100/  |p 10 
999 |a KXP-PPN1663245096  |e 3422347747 
BIB |a Y 
SER |a newspaper 
JSO |a {"type":{"bibl":"article-newspaper","media":"Online-Ressource"},"note":["Gesehen am 15.04.2019"],"recId":"1663245096","language":["eng"],"title":[{"title_sort":"Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves","title":"Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves"}],"person":[{"given":"Danny","family":"Dvir","role":"aut","display":"Dvir, Danny","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Bekeredjian, Raffi","roleDisplay":"VerfasserIn","given":"Raffi","family":"Bekeredjian"}],"physDesc":[{"extent":"10 S."}],"relHost":[{"title":[{"title_sort":"Circulation","title":"Circulation","subtitle":"an official journal of the American Heart Association"}],"language":["eng"],"corporate":[{"role":"isb","display":"American Heart Association","roleDisplay":"Herausgebendes Organ"}],"recId":"265784670","disp":"Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valvesCirculation","note":["Gesehen am 10.10.2025"],"type":{"bibl":"newspaper","media":"Online-Ressource"},"part":{"year":"2012","issue":"19","pages":"2335-2344","volume":"126","text":"126(2012), 19, Seite 2335-2344","extent":"10"},"pubHistory":["1.1950 -"],"id":{"issn":["1524-4539"],"zdb":["1466401-X"],"eki":["265784670"]},"origin":[{"dateIssuedDisp":"1950-","publisher":"Lippincott, Williams & Wilkins ; Ovid","dateIssuedKey":"1950","publisherPlace":"Philadelphia, Pa. ; [Erscheinungsort nicht ermittelbar]"}],"physDesc":[{"extent":"Online-Ressource"}]}],"origin":[{"dateIssuedDisp":"10 Oct 2012","dateIssuedKey":"2012"}],"id":{"doi":["10.1161/CIRCULATIONAHA.112.104505"],"eki":["1663245096"]},"name":{"displayForm":["Danny Dvir, John Webb, Stephen Brecker, Sabine Bleiziffer, David Hildick-Smith, Antonio Colombo, Fleur Descoutures, Christian Hengstenberg, Neil E. Moat, Raffi Bekeredjian, Massimo Napodano, Luca Testa, Thierry Lefevre, Victor Guetta, Henrik Nissen, José-María Hernández, David Roy, Rui C. Teles, Amit Segev, Nicolas Dumonteil, Claudia Fiorina, Michael Gotzmann, Didier Tchetche, Mohamed Abdel-Wahab, Federico De Marco, Andreas Baumbach, Jean-Claude Laborde, Ran Kornowski"]}} 
SRT |a DVIRDANNYBTRANSCATHE1020