Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity: a case report
Abstract Late free flap failures due to pedicle obstruction are rare adverse events. The purpose of this report is to present a case in which the near-infrared indocyanine green video angiography (ICG-NIR-VA) was used to evaluate the perfusion in a compromised fasciocutaneous flap in the late postop...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
24 August 2018
|
| In: |
Microsurgery
Year: 2018, Volume: 38, Issue: 8, Pages: 912-916 |
| ISSN: | 1098-2752 |
| DOI: | 10.1002/micr.30366 |
| Online Access: | Verlag, Volltext: https://doi.org/10.1002/micr.30366 Verlag, Volltext: https://onlinelibrary.wiley.com/doi/full/10.1002/micr.30366 |
| Author Notes: | Felix F. Strübing, Amir K. Bigdeli, Volker J. Schmidt, Spyridoula Maraka, Ulrich Kneser, Dimitra Kotsougiani |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1663460558 | ||
| 003 | DE-627 | ||
| 005 | 20220816140145.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190423s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1002/micr.30366 |2 doi | |
| 035 | |a (DE-627)1663460558 | ||
| 035 | |a (DE-599)KXP1663460558 | ||
| 035 | |a (OCoLC)1341209610 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Strübing, Felix |d 1991- |e VerfasserIn |0 (DE-588)1178373967 |0 (DE-627)1049318501 |0 (DE-576)517755017 |4 aut | |
| 245 | 1 | 0 | |a Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity |b a case report |c Felix F. Strübing, Amir K. Bigdeli, Volker J. Schmidt, Spyridoula Maraka, Ulrich Kneser, Dimitra Kotsougiani |
| 264 | 1 | |c 24 August 2018 | |
| 300 | |a 5 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 23.04.2019 | ||
| 520 | |a Abstract Late free flap failures due to pedicle obstruction are rare adverse events. The purpose of this report is to present a case in which the near-infrared indocyanine green video angiography (ICG-NIR-VA) was used to evaluate the perfusion in a compromised fasciocutaneous flap in the late postoperative period. A 55-year-old male patient, who initially suffered from an open tibial fracture, developed concurrent osteomyelitis with fistulae of the proximal tibia requiring excision. Reconstruction was achieved using a parascapular flap of 25???8?cm, anastomosed to an arterio?venous (AV) Loop in the adductor canal. On the 2nd postoperative day the patient developed a thrombosis of the AV-Loop. After thrombectomy, the postoperative course was uneventful. Seven weeks postoperatively the patient presented with a mottled, partially bluish and cold flap. Anticoagulation prophylaxis was stopped 2?days earlier. Angiography confirmed a thrombus in the arterial pedicle leading to flap ischemia. Near infrared guided fluorescence imaging revealed a delayed recapillarization of the proximal part of the flap closest to the vascular pedicle, albeit flap overall perfusion remained intact. Thus, no surgical intervention was undertaken. However, anticoagulation and prostaglandin therapy was initiated and the flap was salvaged. Genetic analysis uncovered a polymorphism in the prothrombin genes. The flap remained viable and without further complications until the last follow-up visit at 36?weeks after microsurgical reconstruction. The patient was fully mobilized with complete return to function. Near-infrared guided fluorescence imaging may be a viable tool for the assessment of late fasciocutaneous free flap complications and guide the decision-making process. | ||
| 700 | 1 | |a Bigdeli, Amir Khosrow |d 1980- |e VerfasserIn |0 (DE-588)141636246 |0 (DE-627)630399433 |0 (DE-576)325071306 |4 aut | |
| 700 | 1 | |a Schmidt, Volker-Jürgen |d 1979- |e VerfasserIn |0 (DE-588)137709870 |0 (DE-627)594853923 |0 (DE-576)304854921 |4 aut | |
| 700 | 1 | |a Kneser, Ulrich |d 1972- |e VerfasserIn |0 (DE-588)123065119 |0 (DE-627)706147219 |0 (DE-576)293539987 |4 aut | |
| 700 | 1 | |a Kotsougiani-Fischer, Dimitra |d 1983- |e VerfasserIn |0 (DE-588)139135766 |0 (DE-627)703220160 |0 (DE-576)309805066 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Microsurgery |d New York, NY [u.a.] : Wiley-Liss, 1979 |g 38(2018), 8, Seite 912-916 |h Online-Ressource |w (DE-627)269539557 |w (DE-600)1475571-3 |w (DE-576)114617112 |x 1098-2752 |7 nnas |a Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity a case report |
| 773 | 1 | 8 | |g volume:38 |g year:2018 |g number:8 |g pages:912-916 |g extent:5 |a Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity a case report |
| 856 | 4 | 0 | |u https://doi.org/10.1002/micr.30366 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://onlinelibrary.wiley.com/doi/full/10.1002/micr.30366 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190423 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 139135766 |a Kotsougiani-Fischer, Dimitra |m 139135766:Kotsougiani-Fischer, Dimitra |p 6 |y j | ||
| 998 | |g 123065119 |a Kneser, Ulrich |m 123065119:Kneser, Ulrich |d 50000 |e 50000PK123065119 |k 0/50000/ |p 5 | ||
| 998 | |g 137709870 |a Schmidt, Volker-Jürgen |m 137709870:Schmidt, Volker-Jürgen |d 50000 |e 50000PS137709870 |k 0/50000/ |p 3 | ||
| 998 | |g 141636246 |a Bigdeli, Amir Khosrow |m 141636246:Bigdeli, Amir Khosrow |p 2 | ||
| 998 | |g 1178373967 |a Strübing, Felix |m 1178373967:Strübing, Felix |d 50000 |e 50000PS1178373967 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1663460558 |e 3452916219 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Felix F. Strübing, Amir K. Bigdeli, Volker J. Schmidt, Spyridoula Maraka, Ulrich Kneser, Dimitra Kotsougiani"]},"recId":"1663460558","id":{"eki":["1663460558"],"doi":["10.1002/micr.30366"]},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"24 August 2018"}],"physDesc":[{"extent":"5 S."}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"display":"Strübing, Felix","family":"Strübing","given":"Felix","role":"aut"},{"family":"Bigdeli","role":"aut","given":"Amir Khosrow","display":"Bigdeli, Amir Khosrow"},{"display":"Schmidt, Volker-Jürgen","family":"Schmidt","role":"aut","given":"Volker-Jürgen"},{"role":"aut","given":"Ulrich","family":"Kneser","display":"Kneser, Ulrich"},{"display":"Kotsougiani-Fischer, Dimitra","family":"Kotsougiani-Fischer","role":"aut","given":"Dimitra"}],"title":[{"subtitle":"a case report","title":"Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity","title_sort":"Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity"}],"relHost":[{"disp":"Evaluation of perfusion by near-infrared fluorescence imaging in late pedicle obstruction of a parascapular flap to the lower extremity a case reportMicrosurgery","recId":"269539557","part":{"year":"2018","issue":"8","pages":"912-916","volume":"38","extent":"5","text":"38(2018), 8, Seite 912-916"},"id":{"doi":["10.1002/(ISSN)1098-2752"],"eki":["269539557"],"zdb":["1475571-3"],"issn":["1098-2752"]},"origin":[{"dateIssuedDisp":"1979-","dateIssuedKey":"1979","publisher":"Wiley-Liss","publisherPlace":"New York, NY [u.a.]"}],"pubHistory":["1.1979 -"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 05.12.14"],"title":[{"title_sort":"Microsurgery","title":"Microsurgery","subtitle":"official journal of the International Microsurgical Society and the European Federation of Societies for Microsurgery"}]}],"note":["Gesehen am 23.04.2019"]} | ||
| SRT | |a STRUEBINGFEVALUATION2420 | ||