Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms: Cadaveric Study

Background:Indirect screw fixation of the sustentaculum tali in the lateral-medial direction can be challenging due to the complex calcaneal anatomy. A novel 2-dimensional (2D) projection-based software application detects Kirschner wires (K-wires) and visualizes their intended direction as a colore...

Full description

Saved in:
Bibliographic Details
Main Authors: Swartman, Benedict (Author) , Schnetzke, Marc (Author) , Beisemann, Nils (Author) , Keil, Holger (Author) , Franke, Jochen (Author) , Grützner, Paul Alfred (Author) , Vetter, Sven Y. (Author)
Format: Article (Journal)
Language:English
Published: January 19, 2018
In: Foot & ankle international
Year: 2018, Volume: 39, Issue: 4, Pages: 485-492
ISSN:1944-7876
DOI:10.1177/1071100717746618
Online Access:Verlag, Volltext: https://doi.org/10.1177/1071100717746618
Get full text
Author Notes:Benedict Swartman, Dirk Frere, Wei Wei, Marc Schnetzke, Stephan Grechenig, Amir Matityahu, Nils Beisemann, Holger Keil, Jochen Franke, Paul Alfred Grützner, and Sven Yves Vetter

MARC

LEADER 00000caa a2200000 c 4500
001 166381192X
003 DE-627
005 20220816142956.0
007 cr uuu---uuuuu
008 190430s2018 xx |||||o 00| ||eng c
024 7 |a 10.1177/1071100717746618  |2 doi 
035 |a (DE-627)166381192X 
035 |a (DE-599)KXP166381192X 
035 |a (OCoLC)1341212031 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Swartman, Benedict  |d 1985-  |e VerfasserIn  |0 (DE-588)1020286369  |0 (DE-627)691171181  |0 (DE-576)359229727  |4 aut 
245 1 0 |a Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms  |b Cadaveric Study  |c Benedict Swartman, Dirk Frere, Wei Wei, Marc Schnetzke, Stephan Grechenig, Amir Matityahu, Nils Beisemann, Holger Keil, Jochen Franke, Paul Alfred Grützner, and Sven Yves Vetter 
264 1 |c January 19, 2018 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.04.2019 
520 |a Background:Indirect screw fixation of the sustentaculum tali in the lateral-medial direction can be challenging due to the complex calcaneal anatomy. A novel 2-dimensional (2D) projection-based software application detects Kirschner wires (K-wires) and visualizes their intended direction as a colored trajectory. The aim of this prospectively randomized cadaver study was to investigate whether the software would facilitate the indirect K-wire placement in the sustentaculum tali.Methods:In 20 cadaver foot specimens, K-wires were placed indirectly in the sustentaculum tali by an experienced and an inexperienced surgeon, with and without using the application. Number of placement attempts, duration of procedure, fluoroscopy time, and number of individual fluoroscopy images were recorded. Each wire?s position was analyzed in a 3-dimensional (3D) C-arm scan by an experienced blinded investigator.Results:Use of the software by the inexperienced surgeon significantly reduced the number of placement attempts from 3.2 to 1.2 (P = .006). The application also reduced operating time, from 273 s to 199 s (P = .15), and fluoroscopy time, from 41 s to 29 s (P = .15). Using the software, the experienced surgeon had a longer operating time (139 s to 183 s; P = .30), longer fluoroscopy time (5.6 s to 9.2 s; P = .17), and more individual fluoroscopy images (11.6 to 14.8; P = .30). Wire position did not show significant differences in both cases.Conclusion:During indirect K-wire placement in the sustentaculum tali, the software appeared to be a useful tool for the inexperienced surgeon. In our chosen study setting, the experienced surgeon did not benefit from the software.Clinical Relevance:Possible indications for the software would be fractures of the proximal femur, sacrum, sacroiliac instabilities, vertebral bodies, scaphoid, Lisfranc joint, talus and calcaneus. 
700 1 |a Schnetzke, Marc  |d 1984-  |e VerfasserIn  |0 (DE-588)144000873  |0 (DE-627)656392894  |0 (DE-576)340264438  |4 aut 
700 1 |a Beisemann, Nils  |d 1986-  |e VerfasserIn  |0 (DE-588)1069142913  |0 (DE-627)821371940  |0 (DE-576)428434991  |4 aut 
700 1 |a Keil, Holger  |d 1984-  |e VerfasserIn  |0 (DE-588)1019810939  |0 (DE-627)687018048  |0 (DE-576)35890529X  |4 aut 
700 1 |a Franke, Jochen  |d 1974-  |e VerfasserIn  |0 (DE-588)124225373  |0 (DE-627)70657799X  |0 (DE-576)294076654  |4 aut 
700 1 |a Grützner, Paul Alfred  |d 1962-  |e VerfasserIn  |0 (DE-588)111926688  |0 (DE-627)728553473  |0 (DE-576)372572863  |4 aut 
700 1 |a Vetter, Sven Y.  |d 1977-  |e VerfasserIn  |0 (DE-588)13390444X  |0 (DE-627)557959306  |0 (DE-576)300182740  |4 aut 
773 0 8 |i Enthalten in  |t Foot & ankle international  |d Thousand Oaks, Calif. : Sage, 1980  |g 39(2018), 4, Seite 485-492  |h Online-Ressource  |w (DE-627)375974393  |w (DE-600)2129503-7  |w (DE-576)348216424  |x 1944-7876  |7 nnas  |a Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms Cadaveric Study 
773 1 8 |g volume:39  |g year:2018  |g number:4  |g pages:485-492  |g extent:8  |a Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms Cadaveric Study 
856 4 0 |u https://doi.org/10.1177/1071100717746618  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1177/1071100717746618  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190430 
993 |a Article 
994 |a 2018 
998 |g 13390444X  |a Vetter, Sven Y.  |m 13390444X:Vetter, Sven Y.  |d 50000  |e 50000PV13390444X  |k 0/50000/  |p 11  |y j 
998 |g 111926688  |a Grützner, Paul Alfred  |m 111926688:Grützner, Paul Alfred  |d 50000  |e 50000PG111926688  |k 0/50000/  |p 10 
998 |g 124225373  |a Franke, Jochen  |m 124225373:Franke, Jochen  |d 50000  |e 50000PF124225373  |k 0/50000/  |p 9 
998 |g 1019810939  |a Keil, Holger  |m 1019810939:Keil, Holger  |d 50000  |e 50000PK1019810939  |k 0/50000/  |p 8 
998 |g 1069142913  |a Beisemann, Nils  |m 1069142913:Beisemann, Nils  |p 7 
998 |g 144000873  |a Schnetzke, Marc  |m 144000873:Schnetzke, Marc  |p 4 
998 |g 1020286369  |a Swartman, Benedict  |m 1020286369:Swartman, Benedict  |d 50000  |e 50000PS1020286369  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN166381192X  |e 3456391854 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"8 S."}],"title":[{"subtitle":"Cadaveric Study","title":"Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms","title_sort":"Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms"}],"person":[{"given":"Benedict","role":"aut","family":"Swartman","display":"Swartman, Benedict"},{"display":"Schnetzke, Marc","role":"aut","given":"Marc","family":"Schnetzke"},{"role":"aut","given":"Nils","family":"Beisemann","display":"Beisemann, Nils"},{"display":"Keil, Holger","role":"aut","given":"Holger","family":"Keil"},{"given":"Jochen","role":"aut","family":"Franke","display":"Franke, Jochen"},{"family":"Grützner","role":"aut","given":"Paul Alfred","display":"Grützner, Paul Alfred"},{"display":"Vetter, Sven Y.","family":"Vetter","given":"Sven Y.","role":"aut"}],"recId":"166381192X","name":{"displayForm":["Benedict Swartman, Dirk Frere, Wei Wei, Marc Schnetzke, Stephan Grechenig, Amir Matityahu, Nils Beisemann, Holger Keil, Jochen Franke, Paul Alfred Grützner, and Sven Yves Vetter"]},"origin":[{"dateIssuedDisp":"January 19, 2018","dateIssuedKey":"2018"}],"id":{"doi":["10.1177/1071100717746618"],"eki":["166381192X"]},"note":["Gesehen am 30.04.2019"],"relHost":[{"id":{"eki":["375974393"],"zdb":["2129503-7"],"issn":["1944-7876"]},"origin":[{"publisherPlace":"Thousand Oaks, Calif. ; Brooklandville, Md.","dateIssuedKey":"1980","publisher":"Sage ; Data Trace Publ.","dateIssuedDisp":"1980-"}],"part":{"year":"2018","issue":"4","extent":"8","text":"39(2018), 4, Seite 485-492","volume":"39","pages":"485-492"},"recId":"375974393","disp":"Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms Cadaveric StudyFoot & ankle international","title":[{"title_sort":"Foot & ankle international","subtitle":"FAI ; official publication of the American Orthopaedic Foot and Ankle Society (AOFAS)","title":"Foot & ankle international"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 21.01.2014"],"titleAlt":[{"title":"Foot and ankle international"},{"title":"FAI"},{"title":"Foot & ankle"}],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["1.1980 -"],"language":["eng"]}]} 
SRT |a SWARTMANBEWIREPLACEM1920