In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterations

Background/purpose - In-vivo-accuracy analysis (IVA) of dose-delivery with active motion-management (gating/tracking) was performed based on registration of post-radiotherapeutic MRI-morphologic-alterations (MMA) to the corresponding dose-distributions of gantry-based/robotic SBRT-plans. - Methods -...

Full description

Saved in:
Bibliographic Details
Main Authors: Boda-Heggemann, Judit (Author) , Jahnke, Anika (Author) , Attenberger, Ulrike (Author) , Wenz, Frederik (Author)
Format: Article (Journal)
Language:English
Published: 15 February 2019
In: Radiotherapy and oncology
Year: 2019, Volume: 134, Pages: 158-165
ISSN:1879-0887
DOI:10.1016/j.radonc.2019.01.023
Online Access:Verlag, Volltext: https://doi.org/10.1016/j.radonc.2019.01.023
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0167814019300283
Get full text
Author Notes:Judit Boda-Heggemann, Anika Jahnke, Mark K. H. Chan, Floris Ernst, Ardekani Leila Ghaderi, Ulrike Attenberger, Peter Hunold, Jost Philipp Schäfer, Stefan Wurster, Dirk Rades, Guido Hildebrandt, Frank Lohr, Jürgen Dunst, Frederik Wenz, Oliver Blanck

MARC

LEADER 00000caa a2200000 c 4500
001 1665269421
003 DE-627
005 20220816151018.0
007 cr uuu---uuuuu
008 190513s2019 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.radonc.2019.01.023  |2 doi 
035 |a (DE-627)1665269421 
035 |a (DE-599)KXP1665269421 
035 |a (OCoLC)1341212875 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
245 1 0 |a In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterations  |c Judit Boda-Heggemann, Anika Jahnke, Mark K. H. Chan, Floris Ernst, Ardekani Leila Ghaderi, Ulrike Attenberger, Peter Hunold, Jost Philipp Schäfer, Stefan Wurster, Dirk Rades, Guido Hildebrandt, Frank Lohr, Jürgen Dunst, Frederik Wenz, Oliver Blanck 
264 1 |c 15 February 2019 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.05.2019 
520 |a Background/purpose - In-vivo-accuracy analysis (IVA) of dose-delivery with active motion-management (gating/tracking) was performed based on registration of post-radiotherapeutic MRI-morphologic-alterations (MMA) to the corresponding dose-distributions of gantry-based/robotic SBRT-plans. - Methods - Forty targets in two patient cohorts were evaluated: (1) gantry-based SBRT (deep-inspiratory breath-hold-gating; GS) and (2) robotic SBRT (online fiducial-tracking; RS). The planning-CT was deformably registered to the first post-treatment contrast-enhanced T1-weighted MRI. An isodose-structure cropped to the liver (ISL) and corresponding to the contoured MMA was created. Structure and statistical analysis regarding volumes, surface-distance, conformity metrics and center-of-mass-differences (CoMD) was performed. - Results - Liver volume-reduction was −43.1±148.2cc post-RS and −55.8±174.3cc post-GS. The mean surface-distance between MMA and ISL was 2.3±0.8mm (RS) and 2.8±1.1mm (GS). ISL and MMA volumes diverged by 5.1±23.3cc (RS) and 16.5±34.1cc (GS); the median conformity index of both structures was 0.83 (RS) and 0.80 (GS). The average relative directional errors were ≤0.7mm (RS) and ≤0.3mm (GS); the median absolute 3D-CoMD was 3.8mm (RS) and 4.2mm (GS) without statistically significant differences between the two techniques. Factors influencing the IVA included GTV and PTV (p=0.041 and p=0.020). Four local relapses occurred without correlation to IVA. - Conclusions - For the first time a method for IVA was presented, which can serve as a benchmarking-tool for other treatment techniques. Both techniques have shown median deviations <5mm of planned dose and MMA. However, IVA also revealed treatments with errors ≥5mm, suggesting a necessity for patient-specific safety-margins. Nevertheless, the treatment accuracy of well-performed active motion-compensated liver SBRT seems not to be a driving factor for local treatment failure. 
650 4 |a accuracy 
650 4 |a Active motion-management 
650 4 |a DIBH 
650 4 |a Gantry-based SBRT 
650 4 |a Normal tissue reactions 
650 4 |a Robotic SBRT 
700 1 |a Jahnke, Anika  |d 1983-  |e VerfasserIn  |0 (DE-588)1069149470  |0 (DE-627)821383108  |0 (DE-576)42844461X  |4 aut 
700 1 |a Attenberger, Ulrike  |d 1980-  |e VerfasserIn  |0 (DE-588)131554859  |0 (DE-627)510698557  |0 (DE-576)298582775  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
773 0 8 |i Enthalten in  |t Radiotherapy and oncology  |d Amsterdam [u.a.] : Elsevier Science, 1983  |g 134(2019), Seite 158-165  |h Online-Ressource  |w (DE-627)306710110  |w (DE-600)1500707-8  |w (DE-576)082435731  |x 1879-0887  |7 nnas  |a In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterations 
773 1 8 |g volume:134  |g year:2019  |g pages:158-165  |g extent:8  |a In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterations 
856 4 0 |u https://doi.org/10.1016/j.radonc.2019.01.023  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0167814019300283  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190513 
993 |a Article 
994 |a 2019 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |e 60000PW113310390  |k 0/60000/  |p 14 
998 |g 131554859  |a Attenberger, Ulrike  |m 131554859:Attenberger, Ulrike  |d 60000  |d 62900  |e 60000PA131554859  |e 62900PA131554859  |k 0/60000/  |k 1/60000/62900/  |p 6 
998 |g 1069149470  |a Jahnke, Anika  |m 1069149470:Jahnke, Anika  |d 60000  |d 63000  |e 60000PJ1069149470  |e 63000PJ1069149470  |k 0/60000/  |k 1/60000/63000/  |p 2 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |d 63000  |e 60000PB1029853436  |e 63000PB1029853436  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1665269421  |e 3475439875 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 13.05.2019"],"title":[{"title":"In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterations","title_sort":"In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterations"}],"origin":[{"dateIssuedDisp":"15 February 2019","dateIssuedKey":"2019"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"person":[{"display":"Boda-Heggemann, Judit","family":"Boda-Heggemann","role":"aut","given":"Judit"},{"role":"aut","given":"Anika","display":"Jahnke, Anika","family":"Jahnke"},{"given":"Ulrike","role":"aut","family":"Attenberger","display":"Attenberger, Ulrike"},{"given":"Frederik","role":"aut","display":"Wenz, Frederik","family":"Wenz"}],"id":{"eki":["1665269421"],"doi":["10.1016/j.radonc.2019.01.023"]},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["1.1983 -"],"recId":"306710110","id":{"issn":["1879-0887"],"eki":["306710110"],"zdb":["1500707-8"]},"disp":"In-vivo treatment accuracy analysis of active motion-compensated liver SBRT through registration of plan dose to post-therapeutic MRI-morphologic alterationsRadiotherapy and oncology","note":["Gesehen am 30.05.15","Ungezählte Beil.: Supplement"],"title":[{"title_sort":"Radiotherapy and oncology","subtitle":"journal of the European Society for Therapeutic Radiology and Oncology","title":"Radiotherapy and oncology"}],"origin":[{"dateIssuedDisp":"1983-","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science","dateIssuedKey":"1983"}],"titleAlt":[{"title":"The green journal"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"year":"2019","text":"134(2019), Seite 158-165","pages":"158-165","extent":"8","volume":"134"},"language":["eng"]}],"physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Judit Boda-Heggemann, Anika Jahnke, Mark K. H. Chan, Floris Ernst, Ardekani Leila Ghaderi, Ulrike Attenberger, Peter Hunold, Jost Philipp Schäfer, Stefan Wurster, Dirk Rades, Guido Hildebrandt, Frank Lohr, Jürgen Dunst, Frederik Wenz, Oliver Blanck"]},"recId":"1665269421"} 
SRT |a BODAHEGGEMINVIVOTREA1520