Improved compressed sensing reconstruction for 19F magnetic resonance imaging

ObjectiveIn magnetic resonance imaging (MRI), compressed sensing (CS) enables the reconstruction of undersampled sparse data sets. Thus, partial acquisition of the underlying k-space data is sufficient, which significantly reduces measurement time. While 19F MRI data sets are spatially sparse, they...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kampf, Thomas (VerfasserIn) , Sturm, Volker Jörg Friedrich (VerfasserIn) , Buschle, Lukas R. (VerfasserIn) , Kurz, Felix T. (VerfasserIn) , Schlemmer, Heinz-Peter (VerfasserIn) , Ziener, Christian H. (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Bendszus, Martin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2 January 2019
In: Magnetic resonance materials in physics, biology and medicine
Year: 2019, Jahrgang: 32, Heft: 1, Pages: 63-77
ISSN:1352-8661
DOI:10.1007/s10334-018-0729-1
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s10334-018-0729-1
Volltext
Verfasserangaben:Thomas Kampf, Volker J.F. Sturm, Thomas C. Basse-Lüsebrink, André Fischer, Lukas R. Buschle, Felix T. Kurz, Heinz-Peter Schlemmer, Christian H. Ziener, Sabine Heiland, Martin Bendszus, Mirko Pham, Guido Stoll, Peter M. Jakob

MARC

LEADER 00000caa a2200000 c 4500
001 1665925108
003 DE-627
005 20230427160303.0
007 cr uuu---uuuuu
008 190520s2019 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10334-018-0729-1  |2 doi 
035 |a (DE-627)1665925108 
035 |a (DE-599)KXP1665925108 
035 |a (OCoLC)1341224982 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kampf, Thomas  |e VerfasserIn  |0 (DE-588)1174903597  |0 (DE-627)1045796859  |0 (DE-576)515983969  |4 aut 
245 1 0 |a Improved compressed sensing reconstruction for 19F magnetic resonance imaging  |c Thomas Kampf, Volker J.F. Sturm, Thomas C. Basse-Lüsebrink, André Fischer, Lukas R. Buschle, Felix T. Kurz, Heinz-Peter Schlemmer, Christian H. Ziener, Sabine Heiland, Martin Bendszus, Mirko Pham, Guido Stoll, Peter M. Jakob 
246 3 3 |a Improved compressed sensing reconstruction for nineteen F magnetic resonance imaging 
264 1 |c 2 January 2019 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Im Text ist die Zahl 19 hochgestellt 
500 |a Gesehen am 20.05.2019 
520 |a ObjectiveIn magnetic resonance imaging (MRI), compressed sensing (CS) enables the reconstruction of undersampled sparse data sets. Thus, partial acquisition of the underlying k-space data is sufficient, which significantly reduces measurement time. While 19F MRI data sets are spatially sparse, they often suffer from low SNR. This can lead to artifacts in CS reconstructions that reduce the image quality. We present a method to improve the image quality of undersampled, reconstructed CS data sets.Materials and methodsTwo resampling strategies in combination with CS reconstructions are presented. Numerical simulations are performed for low-SNR spatially sparse data obtained from 19F chemical-shift imaging measurements. Different parameter settings for undersampling factors and SNR values are tested and the error is quantified in terms of the root-mean-square error.ResultsAn improvement in overall image quality compared to conventional CS reconstructions was observed for both strategies. Specifically spike artifacts in the background were suppressed, while the changes in signal pixels remained small. DiscussionThe proposed methods improve the quality of CS reconstructions. Furthermore, because resampling is applied during post-processing, no additional measurement time is required. This allows easy incorporation into existing protocols and application to already measured data. 
650 4 |a 19F 
650 4 |a Artifact 
650 4 |a Compressed sensing 
650 4 |a CSI 
650 4 |a MRI 
650 4 |a MRSI 
650 4 |a Sparse 
700 1 |a Sturm, Volker Jörg Friedrich  |d 1980-  |e VerfasserIn  |0 (DE-588)1096228149  |0 (DE-627)856637238  |0 (DE-576)467929971  |4 aut 
700 1 |a Buschle, Lukas R.  |e VerfasserIn  |0 (DE-588)1138362573  |0 (DE-627)895871963  |0 (DE-576)492500517  |4 aut 
700 1 |a Kurz, Felix T.  |d 1981-  |e VerfasserIn  |0 (DE-588)1043285474  |0 (DE-627)771321066  |0 (DE-576)394610342  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Ziener, Christian H.  |d 1978-  |e VerfasserIn  |0 (DE-588)137982755  |0 (DE-627)59885309X  |0 (DE-576)306117355  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance materials in physics, biology and medicine  |d Heidelberg : Springer, 1993  |g 32(2019), 1, Seite 63-77  |h Online-Ressource  |w (DE-627)308449711  |w (DE-600)1502491-X  |w (DE-576)113948557  |x 1352-8661  |7 nnas  |a Improved compressed sensing reconstruction for 19F magnetic resonance imaging 
773 1 8 |g volume:32  |g year:2019  |g number:1  |g pages:63-77  |g extent:15  |a Improved compressed sensing reconstruction for 19F magnetic resonance imaging 
856 4 0 |u https://doi.org/10.1007/s10334-018-0729-1  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20190520 
993 |a Article 
994 |a 2019 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 10 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 9 
998 |g 137982755  |a Ziener, Christian H.  |m 137982755:Ziener, Christian H.  |d 910000  |d 911100  |e 910000PZ137982755  |e 911100PZ137982755  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 7 
998 |g 1043285474  |a Kurz, Felix T.  |m 1043285474:Kurz, Felix T.  |d 910000  |d 911100  |e 910000PK1043285474  |e 911100PK1043285474  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 1138362573  |a Buschle, Lukas R.  |m 1138362573:Buschle, Lukas R.  |d 50000  |e 50000PB1138362573  |k 0/50000/  |p 5 
998 |g 1096228149  |a Sturm, Volker Jörg Friedrich  |m 1096228149:Sturm, Volker Jörg Friedrich  |d 910000  |d 911100  |e 910000PS1096228149  |e 911100PS1096228149  |k 0/910000/  |k 1/910000/911100/  |p 2 
999 |a KXP-PPN1665925108  |e 3478240603 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1665925108","physDesc":[{"extent":"15 S."}],"title":[{"title_sort":"Improved compressed sensing reconstruction for 19F magnetic resonance imaging","title":"Improved compressed sensing reconstruction for 19F magnetic resonance imaging"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Im Text ist die Zahl 19 hochgestellt","Gesehen am 20.05.2019"],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"2 January 2019"}],"relHost":[{"corporate":[{"display":"European Society of Magnetic Resonance in Medicine and Biology","role":"isb"}],"titleAlt":[{"title":"Magma"},{"title":"Magma"}],"pubHistory":["1.1993 -"],"part":{"volume":"32","year":"2019","text":"32(2019), 1, Seite 63-77","extent":"15","issue":"1","pages":"63-77"},"id":{"zdb":["1502491-X"],"issn":["1352-8661"],"eki":["308449711"]},"origin":[{"publisher":"Springer ; Elsevier Science","dateIssuedDisp":"1993-","dateIssuedKey":"1993","publisherPlace":"Heidelberg ; Amsterdam [u.a.]"}],"note":["Gesehen am 18.10.05","Ungezählte Beil.: Supplement"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title":"Magnetic resonance materials in physics, biology and medicine","title_sort":"Magnetic resonance materials in physics, biology and medicine","subtitle":"(MAGMA) ; the official journal of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB)"}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"308449711","disp":"Improved compressed sensing reconstruction for 19F magnetic resonance imagingMagnetic resonance materials in physics, biology and medicine"}],"person":[{"role":"aut","given":"Thomas","family":"Kampf","display":"Kampf, Thomas"},{"given":"Volker Jörg Friedrich","role":"aut","family":"Sturm","display":"Sturm, Volker Jörg Friedrich"},{"family":"Buschle","given":"Lukas R.","role":"aut","display":"Buschle, Lukas R."},{"display":"Kurz, Felix T.","given":"Felix T.","role":"aut","family":"Kurz"},{"display":"Schlemmer, Heinz-Peter","family":"Schlemmer","given":"Heinz-Peter","role":"aut"},{"family":"Ziener","given":"Christian H.","role":"aut","display":"Ziener, Christian H."},{"given":"Sabine","role":"aut","family":"Heiland","display":"Heiland, Sabine"},{"role":"aut","given":"Martin","family":"Bendszus","display":"Bendszus, Martin"}],"id":{"doi":["10.1007/s10334-018-0729-1"],"eki":["1665925108"]},"name":{"displayForm":["Thomas Kampf, Volker J.F. Sturm, Thomas C. Basse-Lüsebrink, André Fischer, Lukas R. Buschle, Felix T. Kurz, Heinz-Peter Schlemmer, Christian H. Ziener, Sabine Heiland, Martin Bendszus, Mirko Pham, Guido Stoll, Peter M. Jakob"]},"titleAlt":[{"title":"Improved compressed sensing reconstruction for nineteen F magnetic resonance imaging"}]} 
SRT |a KAMPFTHOMAIMPROVEDCO2201