Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla

Background Using lower refocusing flip angles in multi-echo turbo spin echo (ME-TSE) sequences at ultra-high magnetic field leads to non-monoexponential signal decay and overestimation of T2 values due to stimulated and secondary echoes. Purpose To investigate the feasibility of a fast and accurate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Emmerich, Julian (VerfasserIn) , Flassbeck, Sebastian (VerfasserIn) , Schmidt, Simon (VerfasserIn) , Bachert, Peter (VerfasserIn) , Ladd, Mark E. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2019
In: Journal of magnetic resonance imaging
Year: 2018, Jahrgang: 49, Heft: 5, Pages: 1253-1262
ISSN:1522-2586
DOI:10.1002/jmri.26516
Online-Zugang:Verlag, Volltext: https://doi.org/10.1002/jmri.26516
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26516
Volltext
Verfasserangaben:Julian Emmerich, Sebastian Flassbeck, Simon Schmidt, Peter Bachert, Mark E. Ladd, and Sina Straub

MARC

LEADER 00000caa a2200000 c 4500
001 1666088501
003 DE-627
005 20220816155707.0
007 cr uuu---uuuuu
008 190522r20192018xx |||||o 00| ||eng c
024 7 |a 10.1002/jmri.26516  |2 doi 
035 |a (DE-627)1666088501 
035 |a (DE-599)KXP1666088501 
035 |a (OCoLC)1341225061 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Emmerich, Julian  |d 1991-  |e VerfasserIn  |0 (DE-588)1212685210  |0 (DE-627)1702688747  |4 aut 
245 1 0 |a Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla  |c Julian Emmerich, Sebastian Flassbeck, Simon Schmidt, Peter Bachert, Mark E. Ladd, and Sina Straub 
264 1 |c 2019 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 22.05.2019 
500 |a First published: 17 October 2018 
520 |a Background Using lower refocusing flip angles in multi-echo turbo spin echo (ME-TSE) sequences at ultra-high magnetic field leads to non-monoexponential signal decay and overestimation of T2 values due to stimulated and secondary echoes. Purpose To investigate the feasibility of a fast and accurate reconstruction of quantitative T2 values using an ME-TSE sequence with reduced refocusing flip angles at 7 Tesla, a dictionary-based reconstruction method was developed and is presented in this work. Study Type Prospective. Subjects Phantom measurements with relaxation phantom, four healthy volunteers. Field Strength/Sequence 7 Tesla MRI, multi-echo turbo spin echo (ME-TSE), spin echo (SE), and B1 mapping. Assessment Based on Bloch simulations and the extended phase graph model, signal decay curves were calculated to account for nonrectangular slice profile, B1 inhomogeneity, and reduced refocusing flip angles and stored in a dictionary. Data obtained with an ME-TSE sequence at 7 Tesla were matched to this dictionary to obtain T2 values. To compare the proposed method to reference T2 values, a spin echo sequence with different echo times was used. Statistical Tests Welch's t-test was used to compare T2 values in phantom measurements. Results T2 values obtained with the proposed ME-TSE method coincided with the T2 values from the spin echo experiment in phantom measurements (P = 0.89 for 120° flip angle, P = 0.75 for 180° flip angle). Only for very low B1 transmit fields, a slight overestimation of T2 values was observed. In vivo measurements showed lower T2 values in gray matter (55 ± 2 millisecond) and white matter (39 ± 5 millisecond) compared with literature values of 3 Tesla data. Data Conclusions The proposed dictionary-based ME-TSE approach provided accurate T2 values in short measurement time at 7 Tesla with low specific absorption rate burden due to the reduction of refocusing flip angles. Therefore, it can provide new opportunities in clinical high-field MRI to further improve radiographic diagnosis by using quantitative imaging. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1253-1262. 
534 |c 2018 
700 1 |a Flassbeck, Sebastian  |d 1991-  |e VerfasserIn  |0 (DE-588)1186277815  |0 (DE-627)1665787066  |4 aut 
700 1 |a Schmidt, Simon  |d 1992-  |e VerfasserIn  |0 (DE-588)1186825561  |0 (DE-627)1666094129  |4 aut 
700 1 |a Bachert, Peter  |e VerfasserIn  |0 (DE-588)1103529633  |0 (DE-627)861285824  |0 (DE-576)251203298  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
773 0 8 |i Enthalten in  |t Journal of magnetic resonance imaging  |d New York, NY : Wiley-Liss, 1991  |g 49(2019), 5, Seite 1253-1262  |h Online-Ressource  |w (DE-627)306360039  |w (DE-600)1497154-9  |w (DE-576)114617252  |x 1522-2586  |7 nnas  |a Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla 
773 1 8 |g volume:49  |g year:2019  |g number:5  |g pages:1253-1262  |g extent:10  |a Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla 
856 4 0 |u https://doi.org/10.1002/jmri.26516  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26516  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190522 
993 |a Article 
994 |a 2019 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 130000  |e 130000PL108120964X  |k 0/130000/  |p 5 
998 |g 1103529633  |a Bachert, Peter  |m 1103529633:Bachert, Peter  |d 130000  |e 130000PB1103529633  |k 0/130000/  |p 4 
998 |g 1186825561  |a Schmidt, Simon  |m 1186825561:Schmidt, Simon  |d 130000  |e 130000PS1186825561  |k 0/130000/  |p 3 
998 |g 1186277815  |a Flassbeck, Sebastian  |m 1186277815:Flassbeck, Sebastian  |d 130000  |e 130000PF1186277815  |k 0/130000/  |p 2 
998 |g 1212685210  |a Emmerich, Julian  |m 1212685210:Emmerich, Julian  |d 130000  |e 130000PE1212685210  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1666088501  |e 3478775248 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"given":"Julian","role":"aut","display":"Emmerich, Julian","family":"Emmerich"},{"given":"Sebastian","role":"aut","display":"Flassbeck, Sebastian","family":"Flassbeck"},{"given":"Simon","role":"aut","display":"Schmidt, Simon","family":"Schmidt"},{"display":"Bachert, Peter","family":"Bachert","role":"aut","given":"Peter"},{"given":"Mark E.","role":"aut","family":"Ladd","display":"Ladd, Mark E."}],"id":{"eki":["1666088501"],"doi":["10.1002/jmri.26516"]},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"306360039","id":{"eki":["306360039"],"doi":["10.1002/(ISSN)1522-2586"],"issn":["1522-2586"],"zdb":["1497154-9"]},"title":[{"title":"Journal of magnetic resonance imaging","subtitle":"JMRI ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Journal of magnetic resonance imaging"}],"origin":[{"publisher":"Wiley-Liss","dateIssuedKey":"1991","dateIssuedDisp":"1991-","publisherPlace":"New York, NY"}],"note":["Gesehen am 28.02.08","Fortsetzung der CD-ROM-Ausgabe"],"pubHistory":["1.1991 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 TeslaJournal of magnetic resonance imaging","language":["eng"],"titleAlt":[{"title":"JMRI"}],"part":{"volume":"49","extent":"10","pages":"1253-1262","year":"2019","issue":"5","text":"49(2019), 5, Seite 1253-1262"}}],"recId":"1666088501","name":{"displayForm":["Julian Emmerich, Sebastian Flassbeck, Simon Schmidt, Peter Bachert, Mark E. Ladd, and Sina Straub"]},"physDesc":[{"extent":"10 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 22.05.2019","First published: 17 October 2018"],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"2019"}],"title":[{"title_sort":"Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla","title":"Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla"}]} 
SRT |a EMMERICHJURAPIDANDAC2019