Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer

Purpose - Dynamic volume perfusion CT (dVPCT) provides valuable information on tissue perfusion in patients with hepatocellular carcinoma (HCC) and pancreatic cancer. However, currently dVPCT is often performed in addition to conventional CT acquisitions due to the limited morphologic image quality...

Full description

Saved in:
Bibliographic Details
Main Authors: Wang, X. (Author) , Henzler, Thomas (Author) , Gawlitza, Joshua Felix Michael (Author) , Diehl, Steffen J. (Author) , Wilhelm, Torsten (Author) , Schönberg, Stefan (Author) , Smakic, Arman (Author)
Format: Article (Journal)
Language:English
Published: November 2016
In: European journal of radiology
Year: 2016, Volume: 85, Issue: 11, Pages: 2104-2110
ISSN:1872-7727
DOI:10.1016/j.ejrad.2016.09.024
Online Access:Verlag, Volltext: https://doi.org/10.1016/j.ejrad.2016.09.024
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X16302935
Get full text
Author Notes:X. Wang (MD), T. Henzler (MD), J. Gawlitza, S. Diehl (MD), T. Wilhelm (MD), S.O. Schoenberg (MD), Z.Y. Jin (MD), H.D. Xue (MD), A. Smakic (MD)

MARC

LEADER 00000caa a2200000 c 4500
001 1667903829
003 DE-627
005 20220816174452.0
007 cr uuu---uuuuu
008 190625s2016 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2016.09.024  |2 doi 
035 |a (DE-627)1667903829 
035 |a (DE-599)KXP1667903829 
035 |a (OCoLC)1341229122 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wang, X.  |e VerfasserIn  |4 aut 
245 1 0 |a Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer  |c X. Wang (MD), T. Henzler (MD), J. Gawlitza, S. Diehl (MD), T. Wilhelm (MD), S.O. Schoenberg (MD), Z.Y. Jin (MD), H.D. Xue (MD), A. Smakic (MD) 
264 1 |c November 2016 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.06.2019 
500 |a Available online 25 September 2016 
520 |a Purpose - Dynamic volume perfusion CT (dVPCT) provides valuable information on tissue perfusion in patients with hepatocellular carcinoma (HCC) and pancreatic cancer. However, currently dVPCT is often performed in addition to conventional CT acquisitions due to the limited morphologic image quality of dose optimized dVPCT protocols. The aim of this study was to prospectively compare objective and subjective image quality, lesion detectability and radiation dose between mean temporal arterial (mTA) and mean temporal portal venous (mTPV) images calculated from low dose dynamic volume perfusion CT (dVPCT) datasets with linearly blended 120-kVp arterial and portal venous datasets in patients with HCC and pancreatic cancer. - Materials and methods - All patients gave written informed consent for this institutional review board-approved HIPAA compliant study. 27 consecutive patients (18 men, 9 women, mean age, 69.1 years±9.4) with histologically proven HCC or suspected pancreatic cancer were prospectively enrolled. The study CT protocol included a dVPCT protocol performed with 70 or 80kVp tube voltage (18 spiral acquisitions, 71.2s total acquisition times) and standard dual-energy (90/150kVpSn) arterial and portal venous acquisition performed 25min after the dVPCT. The mTA and mTPV images were manually reconstructed from the 3 to 5 best visually selected single arterial and 3 to 5 best single portal venous phases dVPCT dataset. The linearly blended 120-kVp images were calculated from dual-energy CT (DECT) raw data. Image noise, SNR, and CNR of the liver, abdominal aorta (AA) and main portal vein (PV) were compared between the mTA/mTPV and the linearly blended 120-kVp dual-energy arterial and portal venous datasets, respectively. Subjective image quality was evaluated by two radiologists regarding subjective image noise, sharpness and overall diagnostic image quality using a 5-point Likert Scale. In addition, liver lesion detectability was performed for each liver segment by the two radiologists using the linearly blended120-kVp arterial and portal venous datasets as the reference standard. - Results - Image noise, SNR and CNR values of the mTA and mTPV were significantly higher when compared to the corresponding linearly blended arterial and portal venous 120-kVp datasets (all p<0.001) except for image noise within the PV in the portal venous phases (p=0.136). - Objective - image quality of mTA and mTPV were rated significantly better when compared to the linearly blended 120-kVp arterial and portal venous datasets. Both readers were able to detect all liver lesions found on the linearly blended 120-kVp arterial and portal venous datasets using the mTA and mTPV datasets. The effective radiation dose of the dVPCT was 27.6mSv for the 80kVp protocol and 14.5mSv for the 70kVp protocol. The mean effective radiation dose for the linearly blended 120-kVp arterial and portal venous CT protocol together of the upper abdomen was 5.60mSv±1.48mSv. - Conclusion - Our preliminary data suggest that subjective and objective image quality of mTA and mTPV datasets calculated from low-kVp dVPCT datasets is non-inferior when compared to linearly blended 120-kVp arterial and portal venous acquisitions in patients with HCC and pancreatic cancer. Thus, dVPCT could be used as a stand-alone imaging technique without additionally performed conventional arterial and portal venous CT acquisitions. 
650 4 |a CT perfusion 
650 4 |a HCC 
650 4 |a Image quality 
650 4 |a Pancreatic cancer 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
700 1 |a Gawlitza, Joshua Felix Michael  |d 1993-  |e VerfasserIn  |0 (DE-588)1177310546  |0 (DE-627)1048680738  |0 (DE-576)517384078  |4 aut 
700 1 |a Diehl, Steffen J.  |e VerfasserIn  |0 (DE-588)1020240881  |0 (DE-627)691154120  |0 (DE-576)359785522  |4 aut 
700 1 |a Wilhelm, Torsten  |d 1970-  |e VerfasserIn  |0 (DE-588)1063991447  |0 (DE-627)812811747  |0 (DE-576)423547828  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Smakic, Arman  |d 1987-  |e VerfasserIn  |0 (DE-588)1159934339  |0 (DE-627)1023018500  |0 (DE-576)505404672  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 85(2016), 11, Seite 2104-2110  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer 
773 1 8 |g volume:85  |g year:2016  |g number:11  |g pages:2104-2110  |g extent:7  |a Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2016.09.024  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0720048X16302935  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190625 
993 |a Article 
994 |a 2016 
998 |g 1159934339  |a Smakic, Arman  |m 1159934339:Smakic, Arman  |d 60000  |d 62900  |e 60000PS1159934339  |e 62900PS1159934339  |k 0/60000/  |k 1/60000/62900/  |p 9  |y j 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 6 
998 |g 1063991447  |a Wilhelm, Torsten  |m 1063991447:Wilhelm, Torsten  |d 60000  |d 61800  |e 60000PW1063991447  |e 61800PW1063991447  |k 0/60000/  |k 1/60000/61800/  |p 5 
998 |g 1020240881  |a Diehl, Steffen J.  |m 1020240881:Diehl, Steffen J.  |d 60000  |d 62900  |e 60000PD1020240881  |e 62900PD1020240881  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 1177310546  |a Gawlitza, Joshua Felix Michael  |m 1177310546:Gawlitza, Joshua Felix Michael  |d 60000  |d 62900  |e 60000PG1177310546  |e 62900PG1177310546  |k 0/60000/  |k 1/60000/62900/  |p 3 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 2 
999 |a KXP-PPN1667903829  |e 3489639138 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1667903829","origin":[{"dateIssuedDisp":"November 2016","dateIssuedKey":"2016"}],"name":{"displayForm":["X. Wang (MD), T. Henzler (MD), J. Gawlitza, S. Diehl (MD), T. Wilhelm (MD), S.O. Schoenberg (MD), Z.Y. Jin (MD), H.D. Xue (MD), A. Smakic (MD)"]},"person":[{"role":"aut","given":"X.","display":"Wang, X.","family":"Wang"},{"display":"Henzler, Thomas","given":"Thomas","family":"Henzler","role":"aut"},{"display":"Gawlitza, Joshua Felix Michael","given":"Joshua Felix Michael","family":"Gawlitza","role":"aut"},{"family":"Diehl","given":"Steffen J.","display":"Diehl, Steffen J.","role":"aut"},{"display":"Wilhelm, Torsten","given":"Torsten","family":"Wilhelm","role":"aut"},{"role":"aut","family":"Schönberg","given":"Stefan","display":"Schönberg, Stefan"},{"family":"Smakic","given":"Arman","display":"Smakic, Arman","role":"aut"}],"language":["eng"],"title":[{"title":"Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer","title_sort":"Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1667903829"],"doi":["10.1016/j.ejrad.2016.09.024"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"pubHistory":["Nachgewiesen 10.1990 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"titleAlt":[{"title":"EJR"}],"disp":"Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancerEuropean journal of radiology","recId":"32044483X","note":["Gesehen am 05.02.20"],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["32044483X"],"zdb":["2005350-2"],"issn":["1872-7727"]},"part":{"issue":"11","extent":"7","pages":"2104-2110","year":"2016","volume":"85","text":"85(2016), 11, Seite 2104-2110"},"title":[{"title":"European journal of radiology","title_sort":"European journal of radiology","subtitle":"EJR"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisher":"Elsevier Science"}]}],"note":["Gesehen am 25.06.2019","Available online 25 September 2016"]} 
SRT |a WANGXHENZLIMAGEQUALI2016