Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta
Prompt-gamma (PG) imaging has the potential for monitoring proton therapy in real time. Different approaches are investigated. We focus on developing multi-slat collimators to image PG quanta, aiming at optimizing collimator performance to detect deviations in treatment delivery. We investigated six...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
[October 2018]
|
| In: |
Physica medica
Year: 2018, Jahrgang: 54, Pages: 1-14 |
| ISSN: | 1724-191X |
| DOI: | 10.1016/j.ejmp.2018.09.001 |
| Online-Zugang: | Verlag, Volltext: https://doi.org/10.1016/j.ejmp.2018.09.001 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1120179718311621 |
| Verfasserangaben: | Patricia Cambraia Lopes, Paulo Crespo, Hugo Simões, Rui Ferreira Marques, Katia Parodi, Dennis R Schaart |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 166879666X | ||
| 003 | DE-627 | ||
| 005 | 20230427221617.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190709s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejmp.2018.09.001 |2 doi | |
| 035 | |a (DE-627)166879666X | ||
| 035 | |a (DE-599)KXP166879666X | ||
| 035 | |a (OCoLC)1341232622 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Lopes, Patricia Cambraia |e VerfasserIn |0 (DE-588)1123664382 |0 (DE-627)87733398X |0 (DE-576)481872248 |4 aut | |
| 245 | 1 | 0 | |a Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta |c Patricia Cambraia Lopes, Paulo Crespo, Hugo Simões, Rui Ferreira Marques, Katia Parodi, Dennis R Schaart |
| 264 | 1 | |c [October 2018] | |
| 300 | |b Illustrationen | ||
| 300 | |a 14 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 17 September 2018 | ||
| 500 | |a Gesehen am 09.07.2019 | ||
| 520 | |a Prompt-gamma (PG) imaging has the potential for monitoring proton therapy in real time. Different approaches are investigated. We focus on developing multi-slat collimators to image PG quanta, aiming at optimizing collimator performance to detect deviations in treatment delivery. We investigated six different multi-slat configurations, which have either optimal (analytical) intrinsic spatial resolution at fixed efficiency, or otherwise; at different distances from the proton pencil-beam axis (15cm-35cm). We used Geant4 to simulate irradiations of the head (energy: 130MeV) and pelvis (200MeV) of an anthropomorphic phantom, with and without physiologic/morphologic or setup changes of clinical dosimetric relevance. The particles escaping the phantom were transported through each of these multi-slat configurations and the gamma counts profiles were recorded at the collimator exit. Median filtering was applied to the registered PG-profiles to mitigate the effects of septa shadowing and statistical fluctuations. Time-of-flight discrimination was used to enhance the signal-to-background ratio, which appeared crucial for 200MeV irradiations. Visual detection of the artificially introduced changes was possible by comparing the PG to the depth-dose profiles. Moreover, 2mm range shifts could be detected in the head irradiation case using a simple linear regression fit to the falloff of the PG-profile. The influence of changes in complex, patient-like dose distributions on the PG-profiles obtained with multi-slat collimation is first studied in this work, which further gives insight on collimator design optimization and highlights its potential and simplicity for detecting proton treatment deviations over a wide range of Bragg peak positions. | ||
| 650 | 4 | |a Anthropomorphic phantom | |
| 650 | 4 | |a Multi-slat collimator | |
| 650 | 4 | |a Prompt gamma imaging | |
| 650 | 4 | |a Shifting time-of-flight | |
| 700 | 1 | |a Crespo, Paulo |e VerfasserIn |4 aut | |
| 700 | 1 | |a Simões, Hugo |e VerfasserIn |4 aut | |
| 700 | 1 | |a Ferreira Marques, Rui |e VerfasserIn |4 aut | |
| 700 | 1 | |a Parodi, Katia |d 1975- |e VerfasserIn |0 (DE-588)129736996 |0 (DE-627)707308917 |0 (DE-576)188641688 |4 aut | |
| 700 | 1 | |a Schaart, Dennis R |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physica medica |d Amsterdam : Elsevier, 1996 |g 54(2018), Seite 1-14 |h Online-Ressource |w (DE-627)364471417 |w (DE-600)2110535-2 |w (DE-576)272350176 |x 1724-191X |7 nnas |a Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta |
| 773 | 1 | 8 | |g volume:54 |g year:2018 |g pages:1-14 |g extent:14 |a Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejmp.2018.09.001 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1120179718311621 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190709 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 129736996 |a Parodi, Katia |m 129736996:Parodi, Katia |p 5 | ||
| 999 | |a KXP-PPN166879666X |e 3492109004 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"doi":["10.1016/j.ejmp.2018.09.001"],"eki":["166879666X"]},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"[October 2018]"}],"name":{"displayForm":["Patricia Cambraia Lopes, Paulo Crespo, Hugo Simões, Rui Ferreira Marques, Katia Parodi, Dennis R Schaart"]},"relHost":[{"id":{"zdb":["2110535-2"],"eki":["364471417"],"issn":["1724-191X"]},"origin":[{"publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedKey":"1996","dateIssuedDisp":"1996-","publisherPlace":"Amsterdam ; Pisa"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Physica medica","subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title_sort":"Physica medica"}],"recId":"364471417","language":["eng"],"disp":"Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quantaPhysica medica","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"part":{"year":"2018","pages":"1-14","volume":"54","text":"54(2018), Seite 1-14","extent":"14"},"pubHistory":["Nachgewiesen 12.1996 -"]}],"physDesc":[{"noteIll":"Illustrationen","extent":"14 S."}],"title":[{"title":"Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta","title_sort":"Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta"}],"person":[{"display":"Lopes, Patricia Cambraia","roleDisplay":"VerfasserIn","role":"aut","family":"Lopes","given":"Patricia Cambraia"},{"given":"Paulo","family":"Crespo","role":"aut","display":"Crespo, Paulo","roleDisplay":"VerfasserIn"},{"given":"Hugo","family":"Simões","role":"aut","roleDisplay":"VerfasserIn","display":"Simões, Hugo"},{"roleDisplay":"VerfasserIn","display":"Ferreira Marques, Rui","role":"aut","family":"Ferreira Marques","given":"Rui"},{"display":"Parodi, Katia","roleDisplay":"VerfasserIn","role":"aut","family":"Parodi","given":"Katia"},{"roleDisplay":"VerfasserIn","display":"Schaart, Dennis R","role":"aut","family":"Schaart","given":"Dennis R"}],"recId":"166879666X","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Available online 17 September 2018","Gesehen am 09.07.2019"]} | ||
| SRT | |a LOPESPATRISIMULATION2018 | ||