Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

Purpose - To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. - Materials and methods - This retrospective study was approved by the institutional research ethics board....

Full description

Saved in:
Bibliographic Details
Main Authors: He, Yong-Lan (Author) , Hausmann, Daniel (Author) , Attenberger, Ulrike (Author) , Schönberg, Stefan (Author) , Riffel, Philipp (Author)
Format: Article (Journal)
Language:English
Published: October 2016
In: European journal of radiology
Year: 2016, Volume: 85, Issue: 10, Pages: 1773-1777
ISSN:1872-7727
DOI:10.1016/j.ejrad.2016.07.022
Online Access:Verlag, Volltext: https://doi.org/10.1016/j.ejrad.2016.07.022
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X1630239X
Get full text
Author Notes:Yong-Lan He, Daniel Hausmann, John N. Morelli, Ulrike I. Attenberger, Stefan O. Schoenberg, Philipp Riffel

MARC

LEADER 00000caa a2200000 c 4500
001 1668819694
003 DE-627
005 20220816185558.0
007 cr uuu---uuuuu
008 190709s2016 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2016.07.022  |2 doi 
035 |a (DE-627)1668819694 
035 |a (DE-599)KXP1668819694 
035 |a (OCoLC)1341233317 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a He, Yong-Lan  |e VerfasserIn  |0 (DE-588)1190114194  |0 (DE-627)1668819252  |4 aut 
245 1 0 |a Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions  |c Yong-Lan He, Daniel Hausmann, John N. Morelli, Ulrike I. Attenberger, Stefan O. Schoenberg, Philipp Riffel 
264 1 |c October 2016 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.07.2019 
500 |a Available online 1 August 2016 
520 |a Purpose - To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. - Materials and methods - This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years±13.4, range 23-83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra®, Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. - Results - With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p<0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p=0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or of renal lesions were observed between the two sequences (all p>0.05). - Conclusion - Image quality, distortion, and susceptibility artifacts might be improved by using z-EPI rather than c-EPI for DWI of the kidney. 
650 4 |a Diffusion-weighted imaging 
650 4 |a Kidney 
650 4 |a Zoomed 
700 1 |a Hausmann, Daniel  |d 1981-  |e VerfasserIn  |0 (DE-588)1012080293  |0 (DE-627)660894432  |0 (DE-576)344897125  |4 aut 
700 1 |a Attenberger, Ulrike  |d 1980-  |e VerfasserIn  |0 (DE-588)131554859  |0 (DE-627)510698557  |0 (DE-576)298582775  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Riffel, Philipp  |d 1982-  |e VerfasserIn  |0 (DE-588)1055978860  |0 (DE-627)793010756  |0 (DE-576)358923433  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 85(2016), 10, Seite 1773-1777  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions 
773 1 8 |g volume:85  |g year:2016  |g number:10  |g pages:1773-1777  |g extent:5  |a Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2016.07.022  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0720048X1630239X  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190709 
993 |a Article 
994 |a 2016 
998 |g 1055978860  |a Riffel, Philipp  |m 1055978860:Riffel, Philipp  |d 60000  |d 62900  |e 60000PR1055978860  |e 62900PR1055978860  |k 0/60000/  |k 1/60000/62900/  |p 6  |y j 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 5 
998 |g 131554859  |a Attenberger, Ulrike  |m 131554859:Attenberger, Ulrike  |d 60000  |d 62900  |e 60000PA131554859  |e 62900PA131554859  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 1012080293  |a Hausmann, Daniel  |m 1012080293:Hausmann, Daniel  |d 60000  |d 62900  |e 60000PH1012080293  |e 62900PH1012080293  |k 0/60000/  |k 1/60000/62900/  |p 2 
999 |a KXP-PPN1668819694  |e 3492180108 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"family":"He","display":"He, Yong-Lan","given":"Yong-Lan","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Hausmann","display":"Hausmann, Daniel","roleDisplay":"VerfasserIn","role":"aut","given":"Daniel"},{"family":"Attenberger","display":"Attenberger, Ulrike","given":"Ulrike","role":"aut","roleDisplay":"VerfasserIn"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Stefan","display":"Schönberg, Stefan","family":"Schönberg"},{"family":"Riffel","role":"aut","roleDisplay":"VerfasserIn","given":"Philipp","display":"Riffel, Philipp"}],"relHost":[{"language":["eng"],"disp":"Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensionsEuropean journal of radiology","physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"1990-","dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]"}],"title":[{"title":"European journal of radiology","title_sort":"European journal of radiology","subtitle":"EJR"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["Nachgewiesen 10.1990 -"],"note":["Gesehen am 05.02.20"],"part":{"pages":"1773-1777","extent":"5","year":"2016","text":"85(2016), 10, Seite 1773-1777","issue":"10","volume":"85"},"recId":"32044483X","id":{"eki":["32044483X"],"zdb":["2005350-2"],"issn":["1872-7727"]},"titleAlt":[{"title":"EJR"}]}],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"October 2016"}],"name":{"displayForm":["Yong-Lan He, Daniel Hausmann, John N. Morelli, Ulrike I. Attenberger, Stefan O. Schoenberg, Philipp Riffel"]},"id":{"doi":["10.1016/j.ejrad.2016.07.022"],"eki":["1668819694"]},"physDesc":[{"extent":"5 S."}],"title":[{"title":"Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions","title_sort":"Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1668819694","note":["Gesehen am 09.07.2019","Available online 1 August 2016"]} 
SRT |a HEYONGLANHRENALZOOME2016