Spectral optimization of iodine-enhanced CT: quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantom
Purpose - To provide an experimental basis for spectral optimization of iodine-enhanced CT by a quantitative analysis of image quality and radiation dose characteristics consistently measured for a large variety of scan settings at an anthropomorphic phantom. - Methods - CT imaging and thermolumines...
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
30 July 2016
|
| In: |
Physica medica
Year: 2016, Jahrgang: 32, Heft: 8, Pages: 999-1006 |
| ISSN: | 1724-191X |
| DOI: | 10.1016/j.ejmp.2016.07.618 |
| Online-Zugang: | Verlag, Volltext: https://doi.org/10.1016/j.ejmp.2016.07.618 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1120179716307517 |
| Verfasserangaben: | Gunnar Brix PhD, Ursula Lechel MS, Sonja Sudarski MD, Christoph Trumm MD, Thomas Henzler MD |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1669221660 | ||
| 003 | DE-627 | ||
| 005 | 20230428192245.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190716s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejmp.2016.07.618 |2 doi | |
| 035 | |a (DE-627)1669221660 | ||
| 035 | |a (DE-599)KXP1669221660 | ||
| 035 | |a (OCoLC)1341233806 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Brix, Gunnar |e VerfasserIn |0 (DE-588)131505742 |0 (DE-627)707649293 |0 (DE-576)298551551 |4 aut | |
| 245 | 1 | 0 | |a Spectral optimization of iodine-enhanced CT |b quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantom |c Gunnar Brix PhD, Ursula Lechel MS, Sonja Sudarski MD, Christoph Trumm MD, Thomas Henzler MD |
| 264 | 1 | |c 30 July 2016 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 16.07.2019 | ||
| 520 | |a Purpose - To provide an experimental basis for spectral optimization of iodine-enhanced CT by a quantitative analysis of image quality and radiation dose characteristics consistently measured for a large variety of scan settings at an anthropomorphic phantom. - Methods - CT imaging and thermoluminescent dosimetry were performed at an anthropomorphic whole-body phantom with iodine inserts for different tube voltages (U, 70-140kV) and current-time products (Q, 60-300mAs). For all U-Q combinations, the iodine contrast (C), the noise level (N) and, from these, the contrast-to-noise ratio (CNR) of reconstructed CT images were determined and parameterized as a function of U, Q or the measured absorbed dose (D). Finally, two characteristic curves were derived that give the relative increase of CNR at constant D and the relative decrease of D at constant CNR when lowering U. - Results - Lowering U affects the measured CNR only slightly but markedly reduces D. For example, reducing U from 120kV to 70kV increases the CNR at constant D by a factor of nearly 1.8 or, alternatively, reduces D at constant CNR by a factor of nearly 5. - Conclusion - Spectral optimization by lowering U is an effective approach to attain the necessary CNR for a specific diagnostic task at hand while at the same time reducing radiation exposure as far as practically achievable. The characteristic curves derived in this study from extensive measurements at a reference ‘person’ can support CT users in an easy-to-use manner to select an appropriate voltage for various clinical scenarios. | ||
| 650 | 4 | |a Contrast-enhanced CT | |
| 650 | 4 | |a Image quality | |
| 650 | 4 | |a Patient exposure | |
| 650 | 4 | |a Spectral optimization | |
| 700 | 1 | |a Janssen, Sonja |d 1987- |e VerfasserIn |0 (DE-588)1033103748 |0 (DE-627)74078871X |0 (DE-576)380756110 |4 aut | |
| 700 | 1 | |a Henzler, Thomas |d 1980- |e VerfasserIn |0 (DE-588)134001486 |0 (DE-627)559468415 |0 (DE-576)276829948 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physica medica |d Amsterdam : Elsevier, 1996 |g 32(2016), 8, Seite 999-1006 |h Online-Ressource |w (DE-627)364471417 |w (DE-600)2110535-2 |w (DE-576)272350176 |x 1724-191X |7 nnas |a Spectral optimization of iodine-enhanced CT quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantom |
| 773 | 1 | 8 | |g volume:32 |g year:2016 |g number:8 |g pages:999-1006 |g extent:8 |a Spectral optimization of iodine-enhanced CT quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantom |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejmp.2016.07.618 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1120179716307517 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190716 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 134001486 |a Henzler, Thomas |m 134001486:Henzler, Thomas |d 60000 |e 60000PH134001486 |k 0/60000/ |p 5 |y j | ||
| 998 | |g 1033103748 |a Janssen, Sonja |m 1033103748:Janssen, Sonja |d 60000 |d 62900 |e 60000PJ1033103748 |e 62900PJ1033103748 |k 0/60000/ |k 1/60000/62900/ |p 3 | ||
| 999 | |a KXP-PPN1669221660 |e 3493591861 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 16.07.2019"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1669221660","language":["eng"],"title":[{"title":"Spectral optimization of iodine-enhanced CT","subtitle":"quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantom","title_sort":"Spectral optimization of iodine-enhanced CT"}],"person":[{"given":"Gunnar","family":"Brix","role":"aut","roleDisplay":"VerfasserIn","display":"Brix, Gunnar"},{"role":"aut","display":"Janssen, Sonja","roleDisplay":"VerfasserIn","given":"Sonja","family":"Janssen"},{"display":"Henzler, Thomas","roleDisplay":"VerfasserIn","role":"aut","family":"Henzler","given":"Thomas"}],"physDesc":[{"extent":"8 S."}],"relHost":[{"origin":[{"publisherPlace":"Amsterdam ; Pisa","dateIssuedKey":"1996","publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedDisp":"1996-"}],"id":{"zdb":["2110535-2"],"eki":["364471417"],"issn":["1724-191X"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title":"Physica medica","title_sort":"Physica medica"}],"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Spectral optimization of iodine-enhanced CT quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantomPhysica medica","recId":"364471417","language":["eng"],"pubHistory":["Nachgewiesen 12.1996 -"],"part":{"extent":"8","text":"32(2016), 8, Seite 999-1006","volume":"32","pages":"999-1006","issue":"8","year":"2016"}}],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"30 July 2016"}],"id":{"eki":["1669221660"],"doi":["10.1016/j.ejmp.2016.07.618"]},"name":{"displayForm":["Gunnar Brix PhD, Ursula Lechel MS, Sonja Sudarski MD, Christoph Trumm MD, Thomas Henzler MD"]}} | ||
| SRT | |a BRIXGUNNARSPECTRALOP3020 | ||