Intraoperative quantitative mitral valve analysis using optical tracking technology
Purpose - Analysis of mitral valve morphology during reconstruction is routinely based on visual assessment and subjective, poorly reproducible measurements. We prove the feasibility of a new intraoperative system for quantitative mitral valve analysis. - Description - The proposed computer-based as...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
20 April 2016
|
| In: |
The annals of thoracic surgery
Year: 2016, Jahrgang: 101, Heft: 5, Pages: 1950-1956 |
| ISSN: | 1552-6259 |
| DOI: | 10.1016/j.athoracsur.2016.01.018 |
| Online-Zugang: | Verlag, Volltext: https://doi.org/10.1016/j.athoracsur.2016.01.018 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0003497516000217 |
| Verfasserangaben: | Sandy Engelhardt, Ivo Wolf, Sameer Al-Maisary, Harald Schmidt, Hans-Peter Meinzer, Matthias Karck, Raffaele De Simone |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1669428923 | ||
| 003 | DE-627 | ||
| 005 | 20241106082238.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190718s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.athoracsur.2016.01.018 |2 doi | |
| 035 | |a (DE-627)1669428923 | ||
| 035 | |a (DE-599)KXP1669428923 | ||
| 035 | |a (OCoLC)1341233867 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Engelhardt, Sandy |d 1987- |e VerfasserIn |0 (DE-588)1122674465 |0 (DE-627)876003080 |0 (DE-576)481436049 |4 aut | |
| 245 | 1 | 0 | |a Intraoperative quantitative mitral valve analysis using optical tracking technology |c Sandy Engelhardt, Ivo Wolf, Sameer Al-Maisary, Harald Schmidt, Hans-Peter Meinzer, Matthias Karck, Raffaele De Simone |
| 264 | 1 | |c 20 April 2016 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 18.07.2019 | ||
| 520 | |a Purpose - Analysis of mitral valve morphology during reconstruction is routinely based on visual assessment and subjective, poorly reproducible measurements. We prove the feasibility of a new intraoperative system for quantitative mitral valve analysis. - Description - The proposed computer-based assistance system enables accurate intraoperative localization of anatomic landmarks on the mitral valve apparatus using optical tracking technology. Measurement and visualization strategies were specifically developed and tailored for mitral valve operations. - Evaluation - The feasibility of intraoperative quantitative measurements was successfully shown for 9 patients. Precise geometric descriptions of the valve were obtained and adequately visualized, providing valuable decision support during the intervention. The mean annular area obtained from the intraoperative measurements was 736 ± 266 mm2, in good agreement with the mean area of the implanted prosthetic rings of 617 ± 124 mm2, which are slightly smaller due to annular downsizing. Comparison with preoperative three-dimensional echocardiography revealed differences between the beating heart, with transverse and septolateral annular diameters of 40.6 ± 15.4 mm and 41.2 ± 8.2 mm, and the intraoperative cardioplegic condition, with corresponding diameters of 34.3 ± 6.9 mm and 27.4 ± 5.6 mm. - Conclusions - Mitral valve analysis by optical tracking represents a unique technologic advance in intraoperative assessment, providing the surgeon with an extended quantitative perception of surgical target. This technology promotes a major philosophical change from an empirical procedure toward a quantitatively predictable modern reconstructive operation. | ||
| 700 | 1 | |a Wolf, Ivo |d 1973- |e VerfasserIn |0 (DE-588)12485186X |0 (DE-627)366973533 |0 (DE-576)29453511X |4 aut | |
| 700 | 1 | |a Maisary, Sameer al- |d 1977- |e VerfasserIn |0 (DE-588)1033341487 |0 (DE-627)740917900 |0 (DE-576)380932172 |4 aut | |
| 700 | 1 | |a Schmidt, Harald |d 19XX- |e VerfasserIn |0 (DE-588)1190845121 |0 (DE-627)1669428613 |4 aut | |
| 700 | 1 | |a Meinzer, Hans-Peter |e VerfasserIn |4 aut | |
| 700 | 1 | |a Karck, Matthias |d 1961- |e VerfasserIn |0 (DE-588)130833525 |0 (DE-627)505909340 |0 (DE-576)298366169 |4 aut | |
| 700 | 1 | |a De Simone, Raffaele |d 1958- |e VerfasserIn |0 (DE-588)1075518466 |0 (DE-627)833385674 |0 (DE-576)443621667 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The annals of thoracic surgery |d Amsterdam [u.a.] : Elsevier Science, 1965 |g 101(2016), 5, Seite 1950-1956 |h Online-Ressource |w (DE-627)306653915 |w (DE-600)1499869-5 |w (DE-576)109633814 |x 1552-6259 |7 nnas |a Intraoperative quantitative mitral valve analysis using optical tracking technology |
| 773 | 1 | 8 | |g volume:101 |g year:2016 |g number:5 |g pages:1950-1956 |g extent:7 |a Intraoperative quantitative mitral valve analysis using optical tracking technology |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.athoracsur.2016.01.018 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0003497516000217 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190718 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 1075518466 |a De Simone, Raffaele |m 1075518466:De Simone, Raffaele |d 910000 |d 910200 |e 910000PD1075518466 |e 910200PD1075518466 |k 0/910000/ |k 1/910000/910200/ |p 7 |y j | ||
| 998 | |g 130833525 |a Karck, Matthias |m 130833525:Karck, Matthias |d 910000 |d 910200 |e 910000PK130833525 |e 910200PK130833525 |k 0/910000/ |k 1/910000/910200/ |p 6 | ||
| 998 | |g 1190845121 |a Schmidt, Harald |m 1190845121:Schmidt, Harald |d 910000 |d 910200 |e 910000PS1190845121 |e 910200PS1190845121 |k 0/910000/ |k 1/910000/910200/ |p 4 | ||
| 998 | |g 1033341487 |a Maisary, Sameer al- |m 1033341487:Maisary, Sameer al- |d 910000 |d 910200 |e 910000PM1033341487 |e 910200PM1033341487 |k 0/910000/ |k 1/910000/910200/ |p 3 | ||
| 998 | |g 12485186X |a Wolf, Ivo |m 12485186X:Wolf, Ivo |d 50000 |e 50000PW12485186X |k 0/50000/ |p 2 | ||
| 998 | |g 1122674465 |a Engelhardt, Sandy |m 1122674465:Engelhardt, Sandy |d 50000 |e 50000PE1122674465 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1669428923 |e 3494785430 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1669428923"],"doi":["10.1016/j.athoracsur.2016.01.018"]},"name":{"displayForm":["Sandy Engelhardt, Ivo Wolf, Sameer Al-Maisary, Harald Schmidt, Hans-Peter Meinzer, Matthias Karck, Raffaele De Simone"]},"note":["Gesehen am 18.07.2019"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Intraoperative quantitative mitral valve analysis using optical tracking technology","title":"Intraoperative quantitative mitral valve analysis using optical tracking technology"}],"person":[{"display":"Engelhardt, Sandy","family":"Engelhardt","given":"Sandy","role":"aut"},{"family":"Wolf","role":"aut","given":"Ivo","display":"Wolf, Ivo"},{"family":"Maisary","role":"aut","given":"Sameer al-","display":"Maisary, Sameer al-"},{"role":"aut","given":"Harald","family":"Schmidt","display":"Schmidt, Harald"},{"family":"Meinzer","given":"Hans-Peter","role":"aut","display":"Meinzer, Hans-Peter"},{"display":"Karck, Matthias","family":"Karck","given":"Matthias","role":"aut"},{"family":"De Simone","given":"Raffaele","role":"aut","display":"De Simone, Raffaele"}],"relHost":[{"recId":"306653915","physDesc":[{"extent":"Online-Ressource"}],"disp":"Intraoperative quantitative mitral valve analysis using optical tracking technologyThe annals of thoracic surgery","origin":[{"publisher":"Elsevier Science","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1965","dateIssuedDisp":"1965-"}],"title":[{"title_sort":"annals of thoracic surgery","title":"The annals of thoracic surgery","subtitle":"official journal of the Society of Thoracic Surgeons and the Southern Thoracic Surgical Association"}],"note":["Gesehen am 04.09.2018"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1965 -"],"corporate":[{"role":"isb","display":"Society of Thoracic Surgeons"},{"display":"Southern Thoracic Surgical Association","role":"isb"}],"part":{"pages":"1950-1956","issue":"5","text":"101(2016), 5, Seite 1950-1956","extent":"7","year":"2016","volume":"101"},"id":{"zdb":["1499869-5"],"eki":["306653915"],"issn":["1552-6259"]}}],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"20 April 2016"}],"physDesc":[{"extent":"7 S."}],"recId":"1669428923"} | ||
| SRT | |a ENGELHARDTINTRAOPERA2020 | ||