Backside wear in acetabular hip joint replacement

Introduction - Besides head-insert articulation in hip joint replacements, micro-motions between the backside of assembled polyethylene acetabular liners and the metal cup may cause additional wear. Pelvic osteolysis frequently occurs in the region of screw holes, and cup loosening hints to clinical...

Full description

Saved in:
Bibliographic Details
Main Authors: Braun, Steffen (Author) , Sonntag, Robert (Author) , Schröder, Stefan (Author) , Müller, Ulrike (Author) , Jäger, Sebastian (Author) , Gotterbarm, Tobias (Author) , Kretzer, Jan Philippe (Author)
Format: Article (Journal)
Language:English
Published: 2019
In: Acta biomaterialia
Year: 2019, Volume: 83, Pages: 467-476
ISSN:1878-7568
DOI:10.1016/j.actbio.2018.10.045
Online Access:Verlag, Volltext: https://doi.org/10.1016/j.actbio.2018.10.045
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1742706118306536
Get full text
Author Notes:Steffen Braun, Robert Sonntag, Stefan Schroeder, Ulrike Mueller, Sebastian Jaeger, Tobias Gotterbarm, Jan Philippe Kretzer

MARC

LEADER 00000caa a2200000 c 4500
001 1670141780
003 DE-627
005 20230417093502.0
007 cr uuu---uuuuu
008 190726s2019 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.actbio.2018.10.045  |2 doi 
035 |a (DE-627)1670141780 
035 |a (DE-599)KXP1670141780 
035 |a (OCoLC)1341234866 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Braun, Steffen  |d 1988-  |e VerfasserIn  |0 (DE-588)1149869429  |0 (DE-627)1010183974  |0 (DE-576)496872729  |4 aut 
245 1 0 |a Backside wear in acetabular hip joint replacement  |c Steffen Braun, Robert Sonntag, Stefan Schroeder, Ulrike Mueller, Sebastian Jaeger, Tobias Gotterbarm, Jan Philippe Kretzer 
264 1 |c 2019 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 5 November 2018 
500 |a Gesehen am 26.07.2019 
520 |a Introduction - Besides head-insert articulation in hip joint replacements, micro-motions between the backside of assembled polyethylene acetabular liners and the metal cup may cause additional wear. Pelvic osteolysis frequently occurs in the region of screw holes, and cup loosening hints to clinically relevant amounts of polyethylene backside wear. It has yet to be confirmed whether backside wear particles differ in size and morphology compared to articulating wear. Previous methods have been limited to subjective assessment of backside surface damages without consideration of wear debris. The aim of this study was to develop and validate a method for quantitative in vitro measurements of polyethylene backside wear in artificial hip cups and to characterize these wear particles for the first time. - Methods - Titanium cup-systems (Plasmafit®Plus7, Aesculap, UHMWPE liner) were sinusoidally loaded (2.5kN) and a torque of 5Nm was simultaneously applied. The front and rear side of the cup were separated to isolate backside wear. After 2×106 cycles the surrounding fluid was filtered and a particle analysis was performed. - Results - Backside wear had a particles size of 64.1±1.9nm and was verified as round and oval particles with partly rough outlines. An estimated total number of particles of 1.26×109±1.67×108 per 106 cycles was determined. - Conclusion - Backside wear was estimated to be several times lower than published values of articulating wear. However, polyethylene backside wear particles represented significantly smaller particles with partly roughened outlines than articulating wear particles and may therefore cause higher biological response in macrophage-mediated bone resorption compared to articulated particles. - Statement of Significance - Within this study, an analytical method for quantitative measuring polyethylene backside wear of artificial hip cups was successfully developed and validated for the first time. It could be shown that backside wear is still present, even in modern cup-systems. These findings can be further used for investigations of the osteolytic potential of polyethylene particles, for evaluating and improving new implant systems and to evaluate the effectiveness of screw hole plugs to prevent the particle migration to the acetabulum. 
650 4 |a Backside wear 
650 4 |a Hip cup system 
650 4 |a Micro-motions 
650 4 |a Particle analysis 
650 4 |a Total hip replacement 
700 1 |a Sonntag, Robert  |e VerfasserIn  |0 (DE-588)1068843756  |0 (DE-627)82081699X  |0 (DE-576)428211135  |4 aut 
700 1 |a Schröder, Stefan  |d 1989-  |e VerfasserIn  |0 (DE-588)1191520447  |0 (DE-627)1670141438  |4 aut 
700 1 |a Müller, Ulrike  |d 1988-  |e VerfasserIn  |0 (DE-588)1116644002  |0 (DE-627)870607081  |0 (DE-576)478555504  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
700 1 |a Gotterbarm, Tobias  |d 1973-  |e VerfasserIn  |0 (DE-588)129590975  |0 (DE-627)473363879  |0 (DE-576)188550968  |4 aut 
700 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
773 0 8 |i Enthalten in  |t Acta biomaterialia  |d [Amsterdam] : Elsevier, 2005  |g 83(2019), Seite 467-476  |h Online-Ressource  |w (DE-627)477531210  |w (DE-600)2173841-5  |w (DE-576)255605226  |x 1878-7568  |7 nnas  |a Backside wear in acetabular hip joint replacement 
773 1 8 |g volume:83  |g year:2019  |g pages:467-476  |g extent:10  |a Backside wear in acetabular hip joint replacement 
856 4 0 |u https://doi.org/10.1016/j.actbio.2018.10.045  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1742706118306536  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190726 
993 |a Article 
994 |a 2019 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |d 50000  |e 910000PK136998348  |e 911460PK136998348  |e 50000PK136998348  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 7  |y j 
998 |g 129590975  |a Gotterbarm, Tobias  |m 129590975:Gotterbarm, Tobias  |d 910000  |d 911460  |e 910000PG129590975  |e 911460PG129590975  |k 0/910000/  |k 1/910000/911460/  |p 6 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 1116644002  |a Müller, Ulrike  |m 1116644002:Müller, Ulrike  |d 910000  |d 911460  |e 910000PM1116644002  |e 911460PM1116644002  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1191520447  |a Schröder, Stefan  |m 1191520447:Schröder, Stefan  |d 910000  |d 911460  |e 910000PS1191520447  |e 911460PS1191520447  |k 0/910000/  |k 1/910000/911460/  |p 3 
998 |g 1068843756  |a Sonntag, Robert  |m 1068843756:Sonntag, Robert  |d 910000  |d 911460  |e 910000PS1068843756  |e 911460PS1068843756  |k 0/910000/  |k 1/910000/911460/  |p 2 
998 |g 1149869429  |a Braun, Steffen  |m 1149869429:Braun, Steffen  |d 910000  |d 911460  |e 910000PB1149869429  |e 911460PB1149869429  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1670141780  |e 349768077X 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Backside wear in acetabular hip joint replacement","title_sort":"Backside wear in acetabular hip joint replacement"}],"note":["Available online 5 November 2018","Gesehen am 26.07.2019"],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"2019"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"10 S."}],"name":{"displayForm":["Steffen Braun, Robert Sonntag, Stefan Schroeder, Ulrike Mueller, Sebastian Jaeger, Tobias Gotterbarm, Jan Philippe Kretzer"]},"relHost":[{"language":["eng"],"part":{"text":"83(2019), Seite 467-476","extent":"10","volume":"83","year":"2019","pages":"467-476"},"recId":"477531210","physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["477531210"],"zdb":["2173841-5"],"issn":["1878-7568"]},"title":[{"title_sort":"Acta biomaterialia","title":"Acta biomaterialia"}],"origin":[{"dateIssuedKey":"2005","publisher":"Elsevier","dateIssuedDisp":"2005-","publisherPlace":"[Amsterdam]"}],"pubHistory":["1.2005 -"],"note":["Gesehen am 09.09.2020"],"disp":"Backside wear in acetabular hip joint replacementActa biomaterialia","type":{"media":"Online-Ressource","bibl":"periodical"}}],"recId":"1670141780","id":{"eki":["1670141780"],"doi":["10.1016/j.actbio.2018.10.045"]},"person":[{"role":"aut","given":"Steffen","family":"Braun","display":"Braun, Steffen"},{"family":"Sonntag","display":"Sonntag, Robert","role":"aut","given":"Robert"},{"given":"Stefan","role":"aut","family":"Schröder","display":"Schröder, Stefan"},{"family":"Müller","display":"Müller, Ulrike","role":"aut","given":"Ulrike"},{"display":"Jäger, Sebastian","family":"Jäger","role":"aut","given":"Sebastian"},{"family":"Gotterbarm","display":"Gotterbarm, Tobias","given":"Tobias","role":"aut"},{"family":"Kretzer","display":"Kretzer, Jan Philippe","given":"Jan Philippe","role":"aut"}],"language":["eng"]} 
SRT |a BRAUNSTEFFBACKSIDEWE2019