Retinal safety evaluation of two-photon laser scanning in rats

Safe use of retinal imaging with two-photon excitation in human eyes is crucial, as the effects of ultrashort pulsed lasers on the retina are relatively unknown. At the time of the study, the laser safety standards were inadequate due to the lack of biological data. This article addresses the feasib...

Full description

Saved in:
Bibliographic Details
Main Authors: Jayabalan, Gopal Swamy (Author) , Bille, Josef F. (Author) , Mao, Xiao Wen (Author) , Gimbel, Howard V. (Author) , Rauser, Michael E. (Author) , Wenz, Frederik (Author) , Fan, Joseph T. (Author)
Format: Article (Journal)
Language:English
Published: 2019
In: Biomedical optics express
Year: 2019, Volume: 10, Issue: 7, Pages: 3217-3231
ISSN:2156-7085
DOI:10.1364/BOE.10.003217
Online Access:Verlag, Volltext: https://doi.org/10.1364/BOE.10.003217
Verlag, kostenfrei, Volltext: https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-7-3217
Get full text
Author Notes:Gopal Swamy Jayabalan, Josef F. Bille, Xiao Wen Mao, Howard V. Gimbel, Michael E. Rauser, Frederik Wenz, Joseph T. Fan

MARC

LEADER 00000caa a2200000 c 4500
001 1670594947
003 DE-627
005 20220816202738.0
007 cr uuu---uuuuu
008 190805s2019 xx |||||o 00| ||eng c
024 7 |a 10.1364/BOE.10.003217  |2 doi 
035 |a (DE-627)1670594947 
035 |a (DE-599)KXP1670594947 
035 |a (OCoLC)1341235273 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jayabalan, Gopal Swamy  |d 1988-  |e VerfasserIn  |0 (DE-588)1164727362  |0 (DE-627)1029015619  |0 (DE-576)510127371  |4 aut 
245 1 0 |a Retinal safety evaluation of two-photon laser scanning in rats  |c Gopal Swamy Jayabalan, Josef F. Bille, Xiao Wen Mao, Howard V. Gimbel, Michael E. Rauser, Frederik Wenz, Joseph T. Fan 
264 1 |c 2019 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.08.2019 
520 |a Safe use of retinal imaging with two-photon excitation in human eyes is crucial, as the effects of ultrashort pulsed lasers on the retina are relatively unknown. At the time of the study, the laser safety standards were inadequate due to the lack of biological data. This article addresses the feasibility of two-photon retinal imaging with respect to laser safety. In this study, rat retinas were evaluated at various laser exposure levels and with different laser parameters to determine the effects of laser-induced optical damage. The results were experimentally verified using confocal reflectance imaging, two-photon fluorescein angiography, immunohistochemistry, and correlated to the IEC 60825-1 laser safety standard. 
650 4 |a Adaptive optics 
650 4 |a High power lasers 
650 4 |a Laser beams 
650 4 |a Laser safety 
650 4 |a Optic nerve 
650 4 |a Retinal nerve fiber layer 
700 1 |a Bille, Josef F.  |d 1944-  |e VerfasserIn  |0 (DE-588)172004640  |0 (DE-627)696901838  |0 (DE-576)132880555  |4 aut 
700 1 |a Mao, Xiao Wen  |e VerfasserIn  |4 aut 
700 1 |a Gimbel, Howard V.  |e VerfasserIn  |4 aut 
700 1 |a Rauser, Michael E.  |e VerfasserIn  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
700 1 |a Fan, Joseph T.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Biomedical optics express  |d Washington, DC : Optica, 2010  |g 10(2019), 7, Seite 3217-3231  |h Online-Ressource  |w (DE-627)635133415  |w (DE-600)2572216-5  |w (DE-576)330122096  |x 2156-7085  |7 nnas  |a Retinal safety evaluation of two-photon laser scanning in rats 
773 1 8 |g volume:10  |g year:2019  |g number:7  |g pages:3217-3231  |g extent:15  |a Retinal safety evaluation of two-photon laser scanning in rats 
856 4 0 |u https://doi.org/10.1364/BOE.10.003217  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-7-3217  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20190805 
993 |a Article 
994 |a 2019 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |e 60000PW113310390  |k 0/60000/  |p 6 
998 |g 172004640  |a Bille, Josef F.  |m 172004640:Bille, Josef F.  |d 130000  |d 130700  |e 130000PB172004640  |e 130700PB172004640  |k 0/130000/  |k 1/130000/130700/  |p 2 
998 |g 1164727362  |a Jayabalan, Gopal Swamy  |m 1164727362:Jayabalan, Gopal Swamy  |d 60000  |e 60000PJ1164727362  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1670594947  |e 3504106611 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"2019","dateIssuedKey":"2019"}],"note":["Gesehen am 05.08.2019"],"title":[{"title_sort":"Retinal safety evaluation of two-photon laser scanning in rats","title":"Retinal safety evaluation of two-photon laser scanning in rats"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"person":[{"given":"Gopal Swamy","role":"aut","display":"Jayabalan, Gopal Swamy","family":"Jayabalan"},{"display":"Bille, Josef F.","family":"Bille","role":"aut","given":"Josef F."},{"role":"aut","given":"Xiao Wen","family":"Mao","display":"Mao, Xiao Wen"},{"display":"Gimbel, Howard V.","family":"Gimbel","role":"aut","given":"Howard V."},{"display":"Rauser, Michael E.","family":"Rauser","role":"aut","given":"Michael E."},{"display":"Wenz, Frederik","family":"Wenz","given":"Frederik","role":"aut"},{"role":"aut","given":"Joseph T.","display":"Fan, Joseph T.","family":"Fan"}],"relHost":[{"part":{"year":"2019","pages":"3217-3231","text":"10(2019), 7, Seite 3217-3231","extent":"15","volume":"10","issue":"7"},"origin":[{"dateIssuedKey":"2010","publisher":"Optica ; Optical Society of America, OSA","dateIssuedDisp":"2010-","publisherPlace":"Washington, DC ; Washington, DC"}],"note":["Gesehen am 10.01.2022","Herausgebendes Organ bis 2021: Optical Society of America"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title":"Biomedical optics express","title_sort":"Biomedical optics express"}],"language":["eng"],"disp":"Retinal safety evaluation of two-photon laser scanning in ratsBiomedical optics express","corporate":[{"role":"isb","display":"Optica"},{"role":"isb","display":"Optical Society of America"}],"id":{"eki":["635133415"],"issn":["2156-7085"],"zdb":["2572216-5"]},"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Optica"]},"recId":"635133415","pubHistory":["1.2010 -"]}],"id":{"eki":["1670594947"],"doi":["10.1364/BOE.10.003217"]},"name":{"displayForm":["Gopal Swamy Jayabalan, Josef F. Bille, Xiao Wen Mao, Howard V. Gimbel, Michael E. Rauser, Frederik Wenz, Joseph T. Fan"]},"physDesc":[{"extent":"15 S."}],"recId":"1670594947"} 
SRT |a JAYABALANGRETINALSAF2019