Retinal safety evaluation of two-photon laser scanning in rats
Safe use of retinal imaging with two-photon excitation in human eyes is crucial, as the effects of ultrashort pulsed lasers on the retina are relatively unknown. At the time of the study, the laser safety standards were inadequate due to the lack of biological data. This article addresses the feasib...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
2019
|
| In: |
Biomedical optics express
Year: 2019, Volume: 10, Issue: 7, Pages: 3217-3231 |
| ISSN: | 2156-7085 |
| DOI: | 10.1364/BOE.10.003217 |
| Online Access: | Verlag, Volltext: https://doi.org/10.1364/BOE.10.003217 Verlag, kostenfrei, Volltext: https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-7-3217 |
| Author Notes: | Gopal Swamy Jayabalan, Josef F. Bille, Xiao Wen Mao, Howard V. Gimbel, Michael E. Rauser, Frederik Wenz, Joseph T. Fan |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1670594947 | ||
| 003 | DE-627 | ||
| 005 | 20220816202738.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190805s2019 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1364/BOE.10.003217 |2 doi | |
| 035 | |a (DE-627)1670594947 | ||
| 035 | |a (DE-599)KXP1670594947 | ||
| 035 | |a (OCoLC)1341235273 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Jayabalan, Gopal Swamy |d 1988- |e VerfasserIn |0 (DE-588)1164727362 |0 (DE-627)1029015619 |0 (DE-576)510127371 |4 aut | |
| 245 | 1 | 0 | |a Retinal safety evaluation of two-photon laser scanning in rats |c Gopal Swamy Jayabalan, Josef F. Bille, Xiao Wen Mao, Howard V. Gimbel, Michael E. Rauser, Frederik Wenz, Joseph T. Fan |
| 264 | 1 | |c 2019 | |
| 300 | |a 15 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 05.08.2019 | ||
| 520 | |a Safe use of retinal imaging with two-photon excitation in human eyes is crucial, as the effects of ultrashort pulsed lasers on the retina are relatively unknown. At the time of the study, the laser safety standards were inadequate due to the lack of biological data. This article addresses the feasibility of two-photon retinal imaging with respect to laser safety. In this study, rat retinas were evaluated at various laser exposure levels and with different laser parameters to determine the effects of laser-induced optical damage. The results were experimentally verified using confocal reflectance imaging, two-photon fluorescein angiography, immunohistochemistry, and correlated to the IEC 60825-1 laser safety standard. | ||
| 650 | 4 | |a Adaptive optics | |
| 650 | 4 | |a High power lasers | |
| 650 | 4 | |a Laser beams | |
| 650 | 4 | |a Laser safety | |
| 650 | 4 | |a Optic nerve | |
| 650 | 4 | |a Retinal nerve fiber layer | |
| 700 | 1 | |a Bille, Josef F. |d 1944- |e VerfasserIn |0 (DE-588)172004640 |0 (DE-627)696901838 |0 (DE-576)132880555 |4 aut | |
| 700 | 1 | |a Mao, Xiao Wen |e VerfasserIn |4 aut | |
| 700 | 1 | |a Gimbel, Howard V. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Rauser, Michael E. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Wenz, Frederik |d 1966- |e VerfasserIn |0 (DE-588)113310390 |0 (DE-627)663837766 |0 (DE-576)346656281 |4 aut | |
| 700 | 1 | |a Fan, Joseph T. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Biomedical optics express |d Washington, DC : Optica, 2010 |g 10(2019), 7, Seite 3217-3231 |h Online-Ressource |w (DE-627)635133415 |w (DE-600)2572216-5 |w (DE-576)330122096 |x 2156-7085 |7 nnas |a Retinal safety evaluation of two-photon laser scanning in rats |
| 773 | 1 | 8 | |g volume:10 |g year:2019 |g number:7 |g pages:3217-3231 |g extent:15 |a Retinal safety evaluation of two-photon laser scanning in rats |
| 856 | 4 | 0 | |u https://doi.org/10.1364/BOE.10.003217 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-7-3217 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190805 | ||
| 993 | |a Article | ||
| 994 | |a 2019 | ||
| 998 | |g 113310390 |a Wenz, Frederik |m 113310390:Wenz, Frederik |d 60000 |e 60000PW113310390 |k 0/60000/ |p 6 | ||
| 998 | |g 172004640 |a Bille, Josef F. |m 172004640:Bille, Josef F. |d 130000 |d 130700 |e 130000PB172004640 |e 130700PB172004640 |k 0/130000/ |k 1/130000/130700/ |p 2 | ||
| 998 | |g 1164727362 |a Jayabalan, Gopal Swamy |m 1164727362:Jayabalan, Gopal Swamy |d 60000 |e 60000PJ1164727362 |k 0/60000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1670594947 |e 3504106611 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedDisp":"2019","dateIssuedKey":"2019"}],"note":["Gesehen am 05.08.2019"],"title":[{"title_sort":"Retinal safety evaluation of two-photon laser scanning in rats","title":"Retinal safety evaluation of two-photon laser scanning in rats"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"person":[{"given":"Gopal Swamy","role":"aut","display":"Jayabalan, Gopal Swamy","family":"Jayabalan"},{"display":"Bille, Josef F.","family":"Bille","role":"aut","given":"Josef F."},{"role":"aut","given":"Xiao Wen","family":"Mao","display":"Mao, Xiao Wen"},{"display":"Gimbel, Howard V.","family":"Gimbel","role":"aut","given":"Howard V."},{"display":"Rauser, Michael E.","family":"Rauser","role":"aut","given":"Michael E."},{"display":"Wenz, Frederik","family":"Wenz","given":"Frederik","role":"aut"},{"role":"aut","given":"Joseph T.","display":"Fan, Joseph T.","family":"Fan"}],"relHost":[{"part":{"year":"2019","pages":"3217-3231","text":"10(2019), 7, Seite 3217-3231","extent":"15","volume":"10","issue":"7"},"origin":[{"dateIssuedKey":"2010","publisher":"Optica ; Optical Society of America, OSA","dateIssuedDisp":"2010-","publisherPlace":"Washington, DC ; Washington, DC"}],"note":["Gesehen am 10.01.2022","Herausgebendes Organ bis 2021: Optical Society of America"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title":"Biomedical optics express","title_sort":"Biomedical optics express"}],"language":["eng"],"disp":"Retinal safety evaluation of two-photon laser scanning in ratsBiomedical optics express","corporate":[{"role":"isb","display":"Optica"},{"role":"isb","display":"Optical Society of America"}],"id":{"eki":["635133415"],"issn":["2156-7085"],"zdb":["2572216-5"]},"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Optica"]},"recId":"635133415","pubHistory":["1.2010 -"]}],"id":{"eki":["1670594947"],"doi":["10.1364/BOE.10.003217"]},"name":{"displayForm":["Gopal Swamy Jayabalan, Josef F. Bille, Xiao Wen Mao, Howard V. Gimbel, Michael E. Rauser, Frederik Wenz, Joseph T. Fan"]},"physDesc":[{"extent":"15 S."}],"recId":"1670594947"} | ||
| SRT | |a JAYABALANGRETINALSAF2019 | ||