Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplasty
Background - Despite the positive results in total shoulder arthroplasties (TSAs), a higher revision rate is documented compared with total hip and knee replacements. Wear is the possible main cause of TSA failure in the long-term. This study investigated the effect of joint kinematics and the influ...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
23 April 2018
|
| In: |
Journal of shoulder and elbow surgery
Year: 2018, Volume: 27, Issue: 9, Pages: 1679-1685 |
| ISSN: | 1532-6500 |
| DOI: | 10.1016/j.jse.2018.02.063 |
| Online Access: | Verlag, Volltext: https://doi.org/10.1016/j.jse.2018.02.063 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1058274618301691 |
| Author Notes: | Steffen Braun, Stefan Schroeder, Ulrike Mueller, Robert Sonntag, Matthias Buelhoff, Jan Philippe Kretzer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1670634310 | ||
| 003 | DE-627 | ||
| 005 | 20220816203039.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190806s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jse.2018.02.063 |2 doi | |
| 035 | |a (DE-627)1670634310 | ||
| 035 | |a (DE-599)KXP1670634310 | ||
| 035 | |a (OCoLC)1341235395 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Braun, Steffen |d 1988- |e VerfasserIn |0 (DE-588)1149869429 |0 (DE-627)1010183974 |0 (DE-576)496872729 |4 aut | |
| 245 | 1 | 0 | |a Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplasty |c Steffen Braun, Stefan Schroeder, Ulrike Mueller, Robert Sonntag, Matthias Buelhoff, Jan Philippe Kretzer |
| 264 | 1 | |c 23 April 2018 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 06.08.2019 | ||
| 520 | |a Background - Despite the positive results in total shoulder arthroplasties (TSAs), a higher revision rate is documented compared with total hip and knee replacements. Wear is the possible main cause of TSA failure in the long-term. This study investigated the effect of joint kinematics and the influence of the rotator cuff on the polyethylene wear performance in an anatomic TSA. - Methods - Lifting a load of 2 kg with an abduction/adduction of 0° to 90° was simulated for 2 × 106 cycles as a primary motion using a fully kinematic joint simulator. A combined rotation in anteversion-retroversion of ±5° and ±10° was also simulated. The force in the superior-inferior direction and the axial joint compression were applied under force control based on in vivo data of the shoulder. A soft tissue restraint model was used to simulate an intact and an insufficient rotator cuff. - Results - The highest wear rate in the intact rotator cuff group was 58.90 ± 1.20 mg/106 cycles with a combined rotation of ±10°. When an insufficient rotator cuff was simulated, the highest polyethylene wear rate determined was 79.67 ± 4.18 mg/106 cycles. - Conclusions - This study confirms a high dependency of the polyethylene wear behavior and dimension on the joint kinematics in total shoulder replacement. This can be explained by an increasing cross-shear stress on the polyethylene component. The results obtained indicate that additional combined kinematics are an indispensable part of wear tests on anatomic shoulder replacements. | ||
| 650 | 4 | |a Anatomic total shoulder arthroplasty | |
| 650 | 4 | |a cross-shear | |
| 650 | 4 | |a joint kinematic | |
| 650 | 4 | |a rotator cuff | |
| 650 | 4 | |a superimposed motion | |
| 650 | 4 | |a wear rate | |
| 700 | 1 | |a Schröder, Stefan |d 1989- |e VerfasserIn |0 (DE-588)1191520447 |0 (DE-627)1670141438 |4 aut | |
| 700 | 1 | |a Müller, Ulrike |d 1988- |e VerfasserIn |0 (DE-588)1116644002 |0 (DE-627)870607081 |0 (DE-576)478555504 |4 aut | |
| 700 | 1 | |a Sonntag, Robert |e VerfasserIn |0 (DE-588)1068843756 |0 (DE-627)82081699X |0 (DE-576)428211135 |4 aut | |
| 700 | 1 | |a Bülhoff, Matthias |d 1984- |e VerfasserIn |0 (DE-588)1069509000 |0 (DE-627)821945009 |0 (DE-576)429201982 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of shoulder and elbow surgery |d St. Louis, Mo. : Mosby, 1992 |g 27(2018), 9, Seite 1679-1685 |h Online-Ressource |w (DE-627)32927029X |w (DE-600)2046901-9 |w (DE-576)09442716X |x 1532-6500 |7 nnas |a Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplasty |
| 773 | 1 | 8 | |g volume:27 |g year:2018 |g number:9 |g pages:1679-1685 |g extent:7 |a Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplasty |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jse.2018.02.063 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1058274618301691 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190806 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |d 50000 |e 910000PK136998348 |e 911460PK136998348 |e 50000PK136998348 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 6 |y j | ||
| 998 | |g 1069509000 |a Bülhoff, Matthias |m 1069509000:Bülhoff, Matthias |d 910000 |d 911460 |e 910000PB1069509000 |e 911460PB1069509000 |k 0/910000/ |k 1/910000/911460/ |p 5 | ||
| 998 | |g 1068843756 |a Sonntag, Robert |m 1068843756:Sonntag, Robert |d 910000 |d 911460 |e 910000PS1068843756 |e 911460PS1068843756 |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 1116644002 |a Müller, Ulrike |m 1116644002:Müller, Ulrike |d 910000 |d 911460 |e 910000PM1116644002 |e 911460PM1116644002 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1191520447 |a Schröder, Stefan |m 1191520447:Schröder, Stefan |d 910000 |d 911460 |e 910000PS1191520447 |e 911460PS1191520447 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 998 | |g 1149869429 |a Braun, Steffen |m 1149869429:Braun, Steffen |d 910000 |d 911460 |e 910000PB1149869429 |e 911460PB1149869429 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1670634310 |e 3504265817 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"note":["Gesehen am 19.02.20"],"title":[{"title_sort":"Journal of shoulder and elbow surgery","title":"Journal of shoulder and elbow surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"9","text":"27(2018), 9, Seite 1679-1685","volume":"27","year":"2018","extent":"7","pages":"1679-1685"},"recId":"32927029X","origin":[{"publisher":"Mosby","dateIssuedDisp":"1992-","dateIssuedKey":"1992","publisherPlace":"St. Louis, Mo."}],"disp":"Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplastyJournal of shoulder and elbow surgery","id":{"zdb":["2046901-9"],"issn":["1532-6500"],"eki":["32927029X"]},"pubHistory":["1.1992 -"],"language":["eng"]}],"person":[{"family":"Braun","role":"aut","display":"Braun, Steffen","given":"Steffen"},{"display":"Schröder, Stefan","given":"Stefan","role":"aut","family":"Schröder"},{"display":"Müller, Ulrike","given":"Ulrike","family":"Müller","role":"aut"},{"family":"Sonntag","role":"aut","given":"Robert","display":"Sonntag, Robert"},{"role":"aut","family":"Bülhoff","given":"Matthias","display":"Bülhoff, Matthias"},{"given":"Jan Philippe","display":"Kretzer, Jan Philippe","family":"Kretzer","role":"aut"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1016/j.jse.2018.02.063"],"eki":["1670634310"]},"name":{"displayForm":["Steffen Braun, Stefan Schroeder, Ulrike Mueller, Robert Sonntag, Matthias Buelhoff, Jan Philippe Kretzer"]},"language":["eng"],"recId":"1670634310","origin":[{"dateIssuedDisp":"23 April 2018","dateIssuedKey":"2018"}],"physDesc":[{"extent":"7 S."}],"title":[{"title":"Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplasty","title_sort":"Influence of joint kinematics on polyethylene wear in anatomic shoulder joint arthroplasty"}],"note":["Gesehen am 06.08.2019"]} | ||
| SRT | |a BRAUNSTEFFINFLUENCEO2320 | ||