Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output

A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance ima...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Trinkmann, Frederik (VerfasserIn) , Dösch, Christina (VerfasserIn) , Papavassiliu, Theano (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Borggrefe, Martin (VerfasserIn) , Kaden, Jens (VerfasserIn) , Saur, Joachim (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2016
In: Journal of clinical monitoring and computing
Year: 2016, Jahrgang: 30, Heft: 4, Pages: 399-408
ISSN:1573-2614
DOI:10.1007/s10877-015-9731-6
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s10877-015-9731-6
Volltext
Verfasserangaben:Frederik Trinkmann, Manuel Berger, Christina Doesch, Theano Papavassiliu, Stefan O. Schoenberg, Martin Borggrefe, Jens J. Kaden, Joachim Saur

MARC

LEADER 00000caa a2200000 c 4500
001 1671450507
003 DE-627
005 20240314104440.0
007 cr uuu---uuuuu
008 190815s2016 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10877-015-9731-6  |2 doi 
035 |a (DE-627)1671450507 
035 |a (DE-599)KXP1671450507 
035 |a (OCoLC)1341237578 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Trinkmann, Frederik  |d 1983-  |e VerfasserIn  |0 (DE-588)142731773  |0 (DE-627)704298066  |0 (DE-576)332907406  |4 aut 
245 1 0 |a Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output  |c Frederik Trinkmann, Manuel Berger, Christina Doesch, Theano Papavassiliu, Stefan O. Schoenberg, Martin Borggrefe, Jens J. Kaden, Joachim Saur 
264 1 |c 2016 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.08.2019 
500 |a Published online: 27 June 2015 
520 |a A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance imaging (CMR) has been performed. We therefore aimed to prospectively assess the accuracy and reproducibility of EV compared to CMR. 152 consecutive stable patients undergoing CMR were enrolled. EV measurements were taken twice before or after CMR in supine position and averaged over 20 s (AESCULON®, Osypka Medical, Berlin, Germany). Bland-Altman analysis showed insufficient agreement of EV and CMR with a mean bias of 1.2 ± 1.4 l/min (bias 23 ± 26 %, percentage error 51 %). Reproducibility was high with 0.0 ± 0.3 l/min (bias 0 ± 8 %, percentage error 15 %). Outlier analysis revealed gender, height, CO and stroke volume (SV) by CMR as independent predictors for larger variation. Stratification of COCMR in quintiles demonstrated a good agreement for low values (<4.4 l/min) with bias increasing significantly with quintile as high as 3.1 ± 1.1 l/min (p < 0.001). Reproducibility was not affected (p = 0.71). Subgroup analysis in patients with arrhythmias (p = 0.19), changes in thoracic fluid content (p = 0.51) or left heart failure (p = 0.47) could not detect significant differences in accuracy. EV showed insufficient agreement with CMR and good reproducibility. Gender, height and increasing CO and SV were associated with increased bias while not affecting reproducibility. Therefore, absolute values should not be used interchangeably in clinical routine. EV yet may find its place for clinical application with further investigation on its trending ability pending. 
650 4 |a Cardiac magnetic resonance imaging 
650 4 |a Cardiac output 
650 4 |a Electrical velocimetry 
650 4 |a Impedance cardiography 
650 4 |a Non-invasive 
700 1 |a Dösch, Christina  |d 1979-  |e VerfasserIn  |0 (DE-588)132004100  |0 (DE-627)516483846  |0 (DE-576)298887207  |4 aut 
700 1 |a Papavassiliu, Theano  |d 1970-  |e VerfasserIn  |0 (DE-588)1028853440  |0 (DE-627)731667417  |0 (DE-576)376292849  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Borggrefe, Martin  |e VerfasserIn  |0 (DE-588)1025920546  |0 (DE-627)725574232  |0 (DE-576)370913426  |4 aut 
700 1 |a Kaden, Jens  |d 1970-  |e VerfasserIn  |0 (DE-588)11803085X  |0 (DE-627)694611581  |0 (DE-576)291676952  |4 aut 
700 1 |a Saur, Joachim  |d 1960-  |e VerfasserIn  |0 (DE-588)1028333811  |0 (DE-627)730581152  |0 (DE-576)375823921  |4 aut 
773 0 8 |i Enthalten in  |t Journal of clinical monitoring and computing  |d Dordrecht [u.a.] : Springer Science + Business Media B.V., 1998  |g 30(2016), 4, Seite 399-408  |h Online-Ressource  |w (DE-627)320483797  |w (DE-600)2010139-9  |w (DE-576)110513010  |x 1573-2614  |7 nnas  |a Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output 
773 1 8 |g volume:30  |g year:2016  |g number:4  |g pages:399-408  |g extent:10  |a Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output 
856 4 0 |u https://doi.org/10.1007/s10877-015-9731-6  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20190815 
993 |a Article 
994 |a 2016 
998 |g 1028333811  |a Saur, Joachim  |m 1028333811:Saur, Joachim  |d 60000  |d 61000  |e 60000PS1028333811  |e 61000PS1028333811  |k 0/60000/  |k 1/60000/61000/  |p 8  |y j 
998 |g 11803085X  |a Kaden, Jens  |m 11803085X:Kaden, Jens  |d 60000  |d 61000  |e 60000PK11803085X  |e 61000PK11803085X  |k 0/60000/  |k 1/60000/61000/  |p 7 
998 |g 1025920546  |a Borggrefe, Martin  |m 1025920546:Borggrefe, Martin  |d 60000  |d 61000  |e 60000PB1025920546  |e 61000PB1025920546  |k 0/60000/  |k 1/60000/61000/  |p 6 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 5 
998 |g 1028853440  |a Papavassiliu, Theano  |m 1028853440:Papavassiliu, Theano  |d 60000  |e 60000PP1028853440  |k 0/60000/  |p 4 
998 |g 132004100  |a Dösch, Christina  |m 132004100:Dösch, Christina  |d 60000  |d 61000  |e 60000PD132004100  |e 61000PD132004100  |k 0/60000/  |k 1/60000/61000/  |p 3 
998 |g 142731773  |a Trinkmann, Frederik  |m 142731773:Trinkmann, Frederik  |d 60000  |d 61000  |e 60000PT142731773  |e 61000PT142731773  |k 0/60000/  |k 1/60000/61000/  |p 1  |x j 
999 |a KXP-PPN1671450507  |e 3507179253 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1007/s10877-015-9731-6"],"eki":["1671450507"]},"name":{"displayForm":["Frederik Trinkmann, Manuel Berger, Christina Doesch, Theano Papavassiliu, Stefan O. Schoenberg, Martin Borggrefe, Jens J. Kaden, Joachim Saur"]},"physDesc":[{"extent":"10 S."}],"recId":"1671450507","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 15.08.2019","Published online: 27 June 2015"],"title":[{"title_sort":"Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output","title":"Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output"}],"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}],"relHost":[{"disp":"Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac outputJournal of clinical monitoring and computing","physDesc":[{"extent":"Online-Ressource"}],"recId":"320483797","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 11.03.25"],"id":{"eki":["320483797"],"issn":["1573-2614"],"zdb":["2010139-9"]},"title":[{"subtitle":"the international journal for technology in anesthesia practice","title":"Journal of clinical monitoring and computing","title_sort":"Journal of clinical monitoring and computing"}],"part":{"volume":"30","year":"2016","text":"30(2016), 4, Seite 399-408","extent":"10","issue":"4","pages":"399-408"},"origin":[{"publisherPlace":"Dordrecht [u.a.] ; Dordrecht [u.a.]","dateIssuedKey":"1998","dateIssuedDisp":"1998-","publisher":"Springer Science + Business Media B.V. ; Kluwer"}],"pubHistory":["Volume 14, issue 1 (January 1998)-"]}],"person":[{"display":"Trinkmann, Frederik","family":"Trinkmann","given":"Frederik","role":"aut"},{"display":"Dösch, Christina","family":"Dösch","given":"Christina","role":"aut"},{"role":"aut","given":"Theano","family":"Papavassiliu","display":"Papavassiliu, Theano"},{"family":"Schönberg","given":"Stefan","role":"aut","display":"Schönberg, Stefan"},{"display":"Borggrefe, Martin","role":"aut","given":"Martin","family":"Borggrefe"},{"role":"aut","given":"Jens","family":"Kaden","display":"Kaden, Jens"},{"given":"Joachim","role":"aut","family":"Saur","display":"Saur, Joachim"}]} 
SRT |a TRINKMANNFCOMPARISON2016