Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning

Ion computed tomography (iCT) represents a potential replacement for x-ray CT (xCT) in ion therapy treatment planning to reduce range uncertainties, inherent in the semi-empirical conversion of xCT information into relative stopping power (RSP). In this work, we aim to quantify the increase in dosim...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Meyer, Sebastian (VerfasserIn) , Kamp, Florian (VerfasserIn) , Tessonnier, Thomas (VerfasserIn) , Mairani, Andrea (VerfasserIn) , Belka, Claus (VerfasserIn) , Carlson, David J. (VerfasserIn) , Gianoli, Chiara (VerfasserIn) , Parodi, Katia (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 12 June 2019
In: Physics in medicine and biology
Year: 2019, Jahrgang: 64, Heft: 12, Pages: 125008
ISSN:1361-6560
DOI:10.1088/1361-6560/ab0fdf
Online-Zugang:Verlag, Volltext: https://doi.org/10.1088/1361-6560/ab0fdf
Verlag, Volltext: https://doi.org/10.1088%2F1361-6560%2Fab0fdf
Volltext
Verfasserangaben:Sebastian Meyer, Florian Kamp, Thomas Tessonnier, Andrea Mairani, Claus Belka, David J. Carlson, Chiara Gianoli and Katia Parodi

MARC

LEADER 00000caa a2200000 c 4500
001 1677362898
003 DE-627
005 20230427002216.0
007 cr uuu---uuuuu
008 190919s2019 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ab0fdf  |2 doi 
035 |a (DE-627)1677362898 
035 |a (DE-599)KXP1677362898 
035 |a (OCoLC)1341244328 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Meyer, Sebastian  |e VerfasserIn  |0 (DE-588)1034705458  |0 (DE-627)746184395  |0 (DE-576)382337093  |4 aut 
245 1 0 |a Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning  |c Sebastian Meyer, Florian Kamp, Thomas Tessonnier, Andrea Mairani, Claus Belka, David J. Carlson, Chiara Gianoli and Katia Parodi 
264 1 |c 12 June 2019 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.09.2019 
520 |a Ion computed tomography (iCT) represents a potential replacement for x-ray CT (xCT) in ion therapy treatment planning to reduce range uncertainties, inherent in the semi-empirical conversion of xCT information into relative stopping power (RSP). In this work, we aim to quantify the increase in dosimetric accuracy associated with using proton-, helium- and carbon-CT compared to conventional xCT for clinical scenarios in proton therapy. Three cases imaged with active beam-delivery using an ideal single-particle-tracking detector were investigated using FLUKA Monte-Carlo (MC) simulations. The RSP accuracy of the iCTs was evaluated against the ground truth at similar physical dose. Next, the resulting dosimetric accuracy was investigated by using the RSP images as a patient model in proton therapy treatment planning, in comparison to common uncertainties associated with xCT. Finally, changes in relative biological effectiveness (RBE) with iCT particle type/spectrum were investigated by incorporating the repair-misrepair-fixation (RMF) model into FLUKA, to enable first insights on the associated biological imaging dose. Helium-CT provided the lowest overall RSP error, whereas carbon-CT offered the highest accuracy for bone and proton-CT for soft tissue. For a single field, the average relative proton beam-range variation was -1.00%, +0.09%, -0.08% and -0.35% for xCT, proton-, helium- and carbon-CT, respectively. Using a 0.5%/0.5mm gamma-evaluation, all iCTs offered comparable accuracy with a better than 99% passing rate, compared to 83% for xCT. The RMF model predictions for RBE for cell death relative to a diagnostic xCT spectrum were 0.82-0.85, 0.85-0.89 and 0.97-1.03 for proton-, helium-, and carbon-CT, respectively. The corresponding RBE for DNA double-strand break induction was generally below one. iCT offers great dinical potential for proton therapy treatment planning by providing superior dose calculation accuracy as well as lower physical and potentially biological dose exposure compared to xCT. For the investigated dose level and ideal detector, proton-CT and helium-CT yielded the best performance. 
650 4 |a carbon computed tomography 
650 4 |a ct 
650 4 |a dose calculation 
650 4 |a energy 
650 4 |a helium computed tomography 
650 4 |a heterogeneous medium 
650 4 |a integration 
650 4 |a ion computed tomography 
650 4 |a monte-carlo-simulation 
650 4 |a path 
650 4 |a performance 
650 4 |a proton computed tomography 
650 4 |a proton therapy 
650 4 |a range uncertainties 
650 4 |a relative biological effectiveness 
650 4 |a repair misrepair-fixation (RMF) model 
650 4 |a x-ray 
700 1 |a Kamp, Florian  |e VerfasserIn  |4 aut 
700 1 |a Tessonnier, Thomas  |e VerfasserIn  |0 (DE-588)1075079195  |0 (DE-627)83292685X  |0 (DE-576)443252270  |4 aut 
700 1 |a Mairani, Andrea  |e VerfasserIn  |0 (DE-588)1116742179  |0 (DE-627)870669281  |0 (DE-576)478592493  |4 aut 
700 1 |a Belka, Claus  |e VerfasserIn  |4 aut 
700 1 |a Carlson, David J.  |e VerfasserIn  |4 aut 
700 1 |a Gianoli, Chiara  |e VerfasserIn  |4 aut 
700 1 |a Parodi, Katia  |d 1975-  |e VerfasserIn  |0 (DE-588)129736996  |0 (DE-627)707308917  |0 (DE-576)188641688  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 64(2019,12) Artikel-Nummer 125008, 10 Seiten  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning 
773 1 8 |g volume:64  |g year:2019  |g number:12  |g pages:125008  |g extent:10  |a Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning 
856 4 0 |u https://doi.org/10.1088/1361-6560/ab0fdf  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1088%2F1361-6560%2Fab0fdf  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190919 
993 |a Article 
994 |a 2019 
998 |g 1075079195  |a Tessonnier, Thomas  |m 1075079195:Tessonnier, Thomas  |p 3 
999 |a KXP-PPN1677362898  |e 3516688505 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1677362898","id":{"eki":["1677362898"],"doi":["10.1088/1361-6560/ab0fdf"]},"language":["eng"],"physDesc":[{"extent":"10 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 19.09.2019"],"person":[{"display":"Meyer, Sebastian","family":"Meyer","roleDisplay":"VerfasserIn","given":"Sebastian","role":"aut"},{"roleDisplay":"VerfasserIn","family":"Kamp","display":"Kamp, Florian","given":"Florian","role":"aut"},{"given":"Thomas","role":"aut","display":"Tessonnier, Thomas","family":"Tessonnier","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Mairani","display":"Mairani, Andrea","role":"aut","given":"Andrea"},{"given":"Claus","role":"aut","roleDisplay":"VerfasserIn","display":"Belka, Claus","family":"Belka"},{"family":"Carlson","display":"Carlson, David J.","roleDisplay":"VerfasserIn","given":"David J.","role":"aut"},{"roleDisplay":"VerfasserIn","family":"Gianoli","display":"Gianoli, Chiara","given":"Chiara","role":"aut"},{"role":"aut","given":"Katia","display":"Parodi, Katia","family":"Parodi","roleDisplay":"VerfasserIn"}],"title":[{"title_sort":"Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning","title":"Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning"}],"origin":[{"dateIssuedDisp":"12 June 2019","dateIssuedKey":"2019"}],"name":{"displayForm":["Sebastian Meyer, Florian Kamp, Thomas Tessonnier, Andrea Mairani, Claus Belka, David J. Carlson, Chiara Gianoli and Katia Parodi"]},"relHost":[{"part":{"volume":"64","pages":"125008","year":"2019","text":"64(2019,12) Artikel-Nummer 125008, 10 Seiten","extent":"10","issue":"12"},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"title":[{"title":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"eki":["269016163"],"zdb":["1473501-5"],"issn":["1361-6560"]},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"1956-","publisher":"IOP Publ.","dateIssuedKey":"1956","publisherPlace":"Bristol"}],"recId":"269016163","pubHistory":["1.1956 -"],"disp":"Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planningPhysics in medicine and biology"}]} 
SRT |a MEYERSEBASDOSIMETRIC1220