Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography device

Objective: Optical coherence tomography (OCT) is a clinical standard in ophthalmology. Currently, its application in dentistry is gaining increasing interest. In this study, we tested the possibility to use a modified commercially available spectral domain OCT (SD-OCT) to assess the layer thickness...

Full description

Saved in:
Bibliographic Details
Main Authors: Şen, Sinan (Author) , Erber, Ralf (Author) , Kunzmann, Kevin (Author) , Kirschner, Stefanie (Author) , Weyer, Vanessa (Author) , Schilling, Lothar (Author) , Rues, Stefan (Author) , Orhan, Gül (Author) , Lux, Christopher J. (Author) , Zingler, Sebastian (Author)
Format: Article (Journal)
Language:English
Published: 09 March 2018
In: Clinical oral investigations
Year: 2018, Volume: 22, Issue: 9, Pages: 3143-3157
ISSN:1436-3771
DOI:10.1007/s00784-018-2410-5
Online Access:Verlag, Volltext: https://doi.org/10.1007/s00784-018-2410-5
Get full text
Author Notes:Sinan Şen, Ralf Erber, Kevin Kunzmann, Stefanie Kirschner, Vanessa Weyer, Lothar Schilling, Marc A. Brockmann, Stefan Rues, Gül Orhan, Christopher J. Lux, Sebastian Zingler

MARC

LEADER 00000caa a2200000 c 4500
001 167790612X
003 DE-627
005 20220816233056.0
007 cr uuu---uuuuu
008 190930s2018 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00784-018-2410-5  |2 doi 
035 |a (DE-627)167790612X 
035 |a (DE-599)KXP167790612X 
035 |a (OCoLC)1341244522 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Şen, Sinan  |d 1986-  |e VerfasserIn  |0 (DE-588)1082311049  |0 (DE-627)847302989  |0 (DE-576)455334501  |4 aut 
245 1 0 |a Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography device  |c Sinan Şen, Ralf Erber, Kevin Kunzmann, Stefanie Kirschner, Vanessa Weyer, Lothar Schilling, Marc A. Brockmann, Stefan Rues, Gül Orhan, Christopher J. Lux, Sebastian Zingler 
264 1 |c 09 March 2018 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.09.2019 
520 |a Objective: Optical coherence tomography (OCT) is a clinical standard in ophthalmology. Currently, its application in dentistry is gaining increasing interest. In this study, we tested the possibility to use a modified commercially available spectral domain OCT (SD-OCT) to assess the layer thickness of orthodontic surface sealants. Materials and methods: Reference samples of surface sealants for calibration and repeatability testing were measured using a micrometer screw. SD-OCT measurements were compared with micro-CT and light microscopic analyses. After validating the calibration of the SD-OCT, surface sealant layer thickness after aging (thermo cycling) and simulation of professional tooth cleaning (PTC) was assessed using the SD-OCT on 45 extracted teeth assigned to three test groups (n = 15 each): Light Bond™ Sealant, Pro Seal®, and Opal® Seal. Results: SD-OCT showed excellent repeatability and accuracy for measurements of surface sealant layer thickness. Compared with micro-CT, SD-OCT showed better accordance with the reference measurements. The analysis of surface sealants after thermo cycling and PTC revealed poor resistance of Light Bond after only aging and demonstrated substantial wear of all sealants after aging and PTC.ConclusionImaging using commercially available ophthalmic SD-OCT might represent a suitable non-invasive methodology for longitudinal assessments of surface sealant layer thickness in vitro and in vivo. Clinical relevance: SD-OCT might be a suitable non-invasive method for longitudinal assessments of surface sealant durability in clinical trials. 
650 4 |a Abrasion 
650 4 |a Optical coherence tomography 
650 4 |a Orthodontics 
650 4 |a Prevention of white spot lesions 
650 4 |a Prophylaxis 
650 4 |a Surface sealants 
700 1 |a Erber, Ralf  |d 1967-  |e VerfasserIn  |0 (DE-588)136076572  |0 (DE-627)69405433X  |0 (DE-576)285643452  |4 aut 
700 1 |a Kunzmann, Kevin  |d 1988-  |e VerfasserIn  |0 (DE-588)1109931751  |0 (DE-627)86460789X  |0 (DE-576)475679687  |4 aut 
700 1 |a Kirschner, Stefanie  |d 1980-  |e VerfasserIn  |0 (DE-588)1075006708  |0 (DE-627)832847429  |0 (DE-576)443195234  |4 aut 
700 1 |a Weyer, Vanessa  |e VerfasserIn  |0 (DE-588)1196033145  |0 (DE-627)1677906987  |4 aut 
700 1 |a Schilling, Lothar  |d 1954-  |e VerfasserIn  |0 (DE-588)1028374690  |0 (DE-627)730623521  |0 (DE-576)375909893  |4 aut 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
700 1 |a Orhan, Gül  |d 1989-  |e VerfasserIn  |0 (DE-588)1196033811  |0 (DE-627)1677907622  |4 aut 
700 1 |a Lux, Christopher J.  |d 1969-  |e VerfasserIn  |0 (DE-588)121600114  |0 (DE-627)081413815  |0 (DE-576)292792549  |4 aut 
700 1 |a Zingler, Sebastian  |d 1976-  |e VerfasserIn  |0 (DE-588)143211390  |0 (DE-627)704421933  |0 (DE-576)335662706  |4 aut 
773 0 8 |i Enthalten in  |t Clinical oral investigations  |d Berlin : Springer, 1997  |g 22(2018), 9, Seite 3143-3157  |h Online-Ressource  |w (DE-627)268756139  |w (DE-600)1472578-2  |w (DE-576)09448029X  |x 1436-3771  |7 nnas  |a Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography device 
773 1 8 |g volume:22  |g year:2018  |g number:9  |g pages:3143-3157  |g extent:15  |a Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography device 
856 4 0 |u https://doi.org/10.1007/s00784-018-2410-5  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20190930 
993 |a Article 
994 |a 2018 
998 |g 143211390  |a Zingler, Sebastian  |m 143211390:Zingler, Sebastian  |d 910000  |d 910800  |e 910000PZ143211390  |e 910800PZ143211390  |k 0/910000/  |k 1/910000/910800/  |p 11  |y j 
998 |g 121600114  |a Lux, Christopher J.  |m 121600114:Lux, Christopher J.  |d 910000  |d 910800  |e 910000PL121600114  |e 910800PL121600114  |k 0/910000/  |k 1/910000/910800/  |p 10 
998 |g 1196033811  |a Orhan, Gül  |m 1196033811:Orhan, Gül  |d 910000  |d 910800  |e 910000PO1196033811  |e 910800PO1196033811  |k 0/910000/  |k 1/910000/910800/  |p 9 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 8 
998 |g 1028374690  |a Schilling, Lothar  |m 1028374690:Schilling, Lothar  |d 60000  |d 62600  |e 60000PS1028374690  |e 62600PS1028374690  |k 0/60000/  |k 1/60000/62600/  |p 6 
998 |g 1196033145  |a Weyer, Vanessa  |m 1196033145:Weyer, Vanessa  |d 60000  |d 63000  |e 60000PW1196033145  |e 63000PW1196033145  |k 0/60000/  |k 1/60000/63000/  |p 5 
998 |g 1075006708  |a Kirschner, Stefanie  |m 1075006708:Kirschner, Stefanie  |d 60000  |d 63000  |e 60000PK1075006708  |e 63000PK1075006708  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1109931751  |a Kunzmann, Kevin  |m 1109931751:Kunzmann, Kevin  |d 910000  |d 999701  |e 910000PK1109931751  |e 999701PK1109931751  |k 0/910000/  |k 1/910000/999701/  |p 3 
998 |g 136076572  |a Erber, Ralf  |m 136076572:Erber, Ralf  |d 910000  |d 910800  |e 910000PE136076572  |e 910800PE136076572  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 1082311049  |a Şen, Sinan  |m 1082311049:Şen, Sinan  |d 910000  |d 910800  |e 910000PS1082311049  |e 910800PS1082311049  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN167790612X  |e 3518995758 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"note":["Gesehen am 30.09.2019"],"physDesc":[{"extent":"15 S."}],"relHost":[{"title":[{"subtitle":"Organ of: Deutsche Gesellschaft für Zahn-, Mund- und Kieferheilkunde","title":"Clinical oral investigations","title_sort":"Clinical oral investigations"}],"disp":"Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography deviceClinical oral investigations","language":["eng"],"note":["Gesehen am 27.10.04"],"part":{"pages":"3143-3157","year":"2018","issue":"9","extent":"15","text":"22(2018), 9, Seite 3143-3157","volume":"22"},"physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisher":"Springer","dateIssuedDisp":"1997-","publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"1997"}],"pubHistory":["1.1997 -"],"recId":"268756139","id":{"eki":["268756139"],"zdb":["1472578-2"],"issn":["1436-3771"]}}],"origin":[{"dateIssuedDisp":"09 March 2018","dateIssuedKey":"2018"}],"title":[{"title":"Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography device","title_sort":"Assessing abrasion of orthodontic surface sealants using a modified ophthalmic optical coherence tomography device"}],"person":[{"role":"aut","family":"Şen","roleDisplay":"VerfasserIn","display":"Şen, Sinan","given":"Sinan"},{"roleDisplay":"VerfasserIn","given":"Ralf","display":"Erber, Ralf","family":"Erber","role":"aut"},{"family":"Kunzmann","given":"Kevin","roleDisplay":"VerfasserIn","display":"Kunzmann, Kevin","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Stefanie","display":"Kirschner, Stefanie","family":"Kirschner"},{"display":"Weyer, Vanessa","roleDisplay":"VerfasserIn","given":"Vanessa","family":"Weyer","role":"aut"},{"given":"Lothar","roleDisplay":"VerfasserIn","display":"Schilling, Lothar","family":"Schilling","role":"aut"},{"role":"aut","family":"Rues","given":"Stefan","roleDisplay":"VerfasserIn","display":"Rues, Stefan"},{"role":"aut","display":"Orhan, Gül","roleDisplay":"VerfasserIn","given":"Gül","family":"Orhan"},{"family":"Lux","roleDisplay":"VerfasserIn","given":"Christopher J.","display":"Lux, Christopher J.","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Zingler, Sebastian","given":"Sebastian","family":"Zingler","role":"aut"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"name":{"displayForm":["Sinan Şen, Ralf Erber, Kevin Kunzmann, Stefanie Kirschner, Vanessa Weyer, Lothar Schilling, Marc A. Brockmann, Stefan Rues, Gül Orhan, Christopher J. Lux, Sebastian Zingler"]},"recId":"167790612X","id":{"eki":["167790612X"],"doi":["10.1007/s00784-018-2410-5"]}} 
SRT |a SENSINANERASSESSINGA0920