Remote monitoring of implantable cardioverter defibrillators: patient experiences and preferences for follow-up

Background Patient satisfaction with remote patient monitoring (RPM) of implantable cardioverter defibrillators (ICDs) seems to be high, yet knowledge on long-term patient experiences is limited. The European REMOTE-CIED study explored patients' experiences with RPM, examined patient's pre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Timmermans, Ivy (VerfasserIn) , Zitron, Edgar (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2019
In: Pacing and clinical electrophysiology
Year: 2018, Jahrgang: 42, Heft: 2, Pages: 120-129
ISSN:1540-8159
DOI:10.1111/pace.13574
Online-Zugang:Verlag, Volltext: https://doi.org/10.1111/pace.13574
Verlag: https://onlinelibrary.wiley.com/doi/abs/10.1111/pace.13574
Volltext
Verfasserangaben:Ivy Timmermans, MSc, Mathias Meine, MD, PhD, Istvan Szendey MD, PhD, Johannes Aring MD, Javier Romero Roldán MD, Lieselotte van Erven MD, PhD, Philipp Kahlert MD, Edgar Zitron MD, PhD, Philippe Mabo MD, PhD, Johan Denollet PhD, Henneke Versteeg PhD

MARC

LEADER 00000caa a2200000 c 4500
001 1678028185
003 DE-627
005 20230428021916.0
007 cr uuu---uuuuu
008 191002r20192018xx |||||o 00| ||eng c
024 7 |a 10.1111/pace.13574  |2 doi 
035 |a (DE-627)1678028185 
035 |a (DE-599)KXP1678028185 
035 |a (OCoLC)1341244753 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Timmermans, Ivy  |e VerfasserIn  |0 (DE-588)1161495576  |0 (DE-627)1024795098  |0 (DE-576)506585778  |4 aut 
245 1 0 |a Remote monitoring of implantable cardioverter defibrillators  |b patient experiences and preferences for follow-up  |c Ivy Timmermans, MSc, Mathias Meine, MD, PhD, Istvan Szendey MD, PhD, Johannes Aring MD, Javier Romero Roldán MD, Lieselotte van Erven MD, PhD, Philipp Kahlert MD, Edgar Zitron MD, PhD, Philippe Mabo MD, PhD, Johan Denollet PhD, Henneke Versteeg PhD 
264 1 |c 2019 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 10 December 2018 
500 |a Gesehen am 19.11.2019 
520 |a Background Patient satisfaction with remote patient monitoring (RPM) of implantable cardioverter defibrillators (ICDs) seems to be high, yet knowledge on long-term patient experiences is limited. The European REMOTE-CIED study explored patients' experiences with RPM, examined patient's preferences for ICD follow-up, and identified determinants of patient's preferences in the first 2 years postimplantation. Methods European heart failure patients (N = 300; median age = 66 years [interquartile range (IQR) = 59-73], and 22% female) with a first-time ICD received a Boston Scientific LATITUDE RPM system (Marlborough, MA, USA) and had scheduled in-clinic follow-ups once a year. Patients completed questionnaires at 1-2 weeks and also at 3, 6, 12, and 24 months postimplantation and clinical data were obtained from their medical records. Patient evaluation data were analyzed descriptively, and Student's t-tests/Man-Whitney U tests or Chi-square tests/Fisher's exact tests were performed to examine determinants of patient preferences. Results At 2 years postimplantation, the median patient satisfaction score with the RPM system was 9 out of 10 (IQR = 8-10), despite 53% of the patients experiencing issues (eg, failure to transmit data). Of the 221 patients who reported their follow-up preferences, 43% preferred RPM and 19% preferred in-clinic follow-up. Patients with a preference for RPM were more likely to be higher educated (P = 0.04), employed (P = 0.04), and equipped with a new LATITUDE model (P = 0.04), but less likely to suffer from chronic obstructive pulmonary disease (P = 0.009). Conclusion In general, patients were highly satisfied with RPM, but a subgroup preferred in-clinic follow-up. Therefore, physicians should include patients’ concerns and preferences in the decision-making process, to tailor device follow-up to individual patients’ needs and preferences. 
534 |c 2018 
650 4 |a implantable cardioverter defibrillator 
650 4 |a patient experiences 
650 4 |a patient preferences 
650 4 |a remote patient monitoring 
700 1 |a Zitron, Edgar  |d 1977-  |e VerfasserIn  |0 (DE-588)130512966  |0 (DE-627)503032549  |0 (DE-576)298241196  |4 aut 
773 0 8 |i Enthalten in  |t Pacing and clinical electrophysiology  |d New York, NY [u.a.] : Wiley-Blackwell, 1978  |g 42(2019), 2, Seite 120-129  |h Online-Ressource  |w (DE-627)325572267  |w (DE-600)2037547-5  |w (DE-576)094108501  |x 1540-8159  |7 nnas  |a Remote monitoring of implantable cardioverter defibrillators patient experiences and preferences for follow-up 
773 1 8 |g volume:42  |g year:2019  |g number:2  |g pages:120-129  |g extent:10  |a Remote monitoring of implantable cardioverter defibrillators patient experiences and preferences for follow-up 
856 4 0 |u https://doi.org/10.1111/pace.13574  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/pace.13574  |x Verlag 
951 |a AR 
992 |a 20191002 
993 |a Article 
994 |a 2019 
998 |g 130512966  |a Zitron, Edgar  |m 130512966:Zitron, Edgar  |d 910000  |d 910100  |e 910000PZ130512966  |e 910100PZ130512966  |k 0/910000/  |k 1/910000/910100/  |p 8 
999 |a KXP-PPN1678028185  |e 3519329883 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1678028185","language":["eng"],"note":["First published: 10 December 2018","Gesehen am 19.11.2019"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"subtitle":"patient experiences and preferences for follow-up","title":"Remote monitoring of implantable cardioverter defibrillators","title_sort":"Remote monitoring of implantable cardioverter defibrillators"}],"person":[{"roleDisplay":"VerfasserIn","display":"Timmermans, Ivy","role":"aut","family":"Timmermans","given":"Ivy"},{"family":"Zitron","given":"Edgar","roleDisplay":"VerfasserIn","display":"Zitron, Edgar","role":"aut"}],"relHost":[{"part":{"year":"2019","pages":"120-129","issue":"2","volume":"42","text":"42(2019), 2, Seite 120-129","extent":"10"},"titleAlt":[{"title":"PACE"}],"pubHistory":["1.1978 -"],"recId":"325572267","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Remote monitoring of implantable cardioverter defibrillators patient experiences and preferences for follow-upPacing and clinical electrophysiology","note":["Gesehen am 12.04.2022"],"title":[{"title_sort":"Pacing and clinical electrophysiology","subtitle":"PACE ; official journal of the International Cardiac Pacing and Electrophysiology Society","title":"Pacing and clinical electrophysiology"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1540-8159","1468-0106"],"zdb":["2037547-5"],"eki":["325572267"],"doi":["10.1111/(ISSN)1540-8159"]},"origin":[{"dateIssuedKey":"1978","publisher":"Wiley-Blackwell ; Blackwell Publ.","dateIssuedDisp":"1978-","publisherPlace":"New York, NY [u.a.] ; New York, NY [u.a.]"}]}],"physDesc":[{"extent":"10 S."}],"id":{"doi":["10.1111/pace.13574"],"eki":["1678028185"]},"origin":[{"dateIssuedDisp":"2019","dateIssuedKey":"2019"}],"name":{"displayForm":["Ivy Timmermans, MSc, Mathias Meine, MD, PhD, Istvan Szendey MD, PhD, Johannes Aring MD, Javier Romero Roldán MD, Lieselotte van Erven MD, PhD, Philipp Kahlert MD, Edgar Zitron MD, PhD, Philippe Mabo MD, PhD, Johan Denollet PhD, Henneke Versteeg PhD"]}} 
SRT |a TIMMERMANSREMOTEMONI2019