Treatment with a CAD-CAM-fabricated, double-crown-retained, removable partial denture: a clinical report
This clinical report describes treatment with a double-crown-retained, removable partial denture with a 2-year follow up. Primary and secondary crowns and a removable partial denture metal-alloy framework were fabricated using computer aided design and computer aided manufacturing (CAD-CAM) and mill...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
2019
|
| In: |
The journal of prosthetic dentistry
Year: 2018, Volume: 121, Issue: 2, Pages: 220-224 |
| ISSN: | 1097-6841 |
| DOI: | 10.1016/j.prosdent.2018.02.019 |
| Online Access: | Verlag, Volltext: https://doi.org/10.1016/j.prosdent.2018.02.019 Verlag: http://www.sciencedirect.com/science/article/pii/S0022391318302300 |
| Author Notes: | Regina A. Danielczak, Dr med dent, Thomas Stober, Prof Dr med dent, and Wolfgang Bömicke, Dr med dent, MSc |
| Summary: | This clinical report describes treatment with a double-crown-retained, removable partial denture with a 2-year follow up. Primary and secondary crowns and a removable partial denture metal-alloy framework were fabricated using computer aided design and computer aided manufacturing (CAD-CAM) and milled from cobalt-chromium (Co-Cr) alloy. |
|---|---|
| Item Description: | Available online 20 July 2018 Gesehen am 24.10.2019 |
| Physical Description: | Online Resource |
| ISSN: | 1097-6841 |
| DOI: | 10.1016/j.prosdent.2018.02.019 |