The "virtual DBS population": five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies

We design, develop, and disseminate a ‘virtual population’ of five realistic computational models of deep brain stimulation (DBS) patients for electromagnetic (EM) analysis. We found five DBS patients in our institution’ research patient database who received high quality post-DBS surgery computer t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Guerin, Bastien (VerfasserIn) , Davids, Mathias (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 4 February 2019
In: Physics in medicine and biology
Year: 2019, Jahrgang: 64, Heft: 3
ISSN:1361-6560
DOI:10.1088/1361-6560/aafce8
Online-Zugang:Verlag, Volltext: https://doi.org/10.1088/1361-6560/aafce8
Verlag: https://iopscience.iop.org/article/10.1088/1361-6560/aafce8
Volltext
Verfasserangaben:Bastien Guerin, Maria Ida Iacono, Mathias Davids, Darin Dougherty, Leonardo M. Angelone and Lawrence L. Wald

MARC

LEADER 00000caa a2200000 c 4500
001 1678145424
003 DE-627
005 20230428021927.0
007 cr uuu---uuuuu
008 191004s2019 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/aafce8  |2 doi 
035 |a (DE-627)1678145424 
035 |a (DE-599)KXP1678145424 
035 |a (OCoLC)1341244515 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Guerin, Bastien  |e VerfasserIn  |0 (DE-588)1197829660  |0 (DE-627)1679738844  |4 aut 
245 1 4 |a The "virtual DBS population"  |b five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies  |c Bastien Guerin, Maria Ida Iacono, Mathias Davids, Darin Dougherty, Leonardo M. Angelone and Lawrence L. Wald 
264 1 |c 4 February 2019 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.10.2019 
520 |a We design, develop, and disseminate a ‘virtual population’ of five realistic computational models of deep brain stimulation (DBS) patients for electromagnetic (EM) analysis. We found five DBS patients in our institution’ research patient database who received high quality post-DBS surgery computer tomography (CT) examinations of the head and neck. Three patients have a single implanted pulse generator (IPG) and the two others have two IPGs (one for each lead). Moreover, one patient has two abandoned leads on each side of the head. For each patient, we combined the head and neck volumes into a ‘virtual CT’, from which we extracted the full-length DBS path including the IPG, extension cables, and leads. We corrected topology errors in this path, such as self-intersections, using a previously published optimization procedure. We segmented the virtual CT volume into bones, internal air, and soft tissue classes and created two-manifold, watertight surface meshes of these distributions. In addition, we added a segmented model of the brain (grey matter, white matter, eyes and cerebrospinal fluid) to one of the model (nickname Freddie) that was derived from a T1-weighted MR image obtained prior to the DBS implantation. We simulated the EM fields and specific absorption rate (SAR) induced at 3 Tesla by a quadrature birdcage body coil in each of the five patient models using a co-simulation strategy. We found that inter-subject peak SAR variability across models was independent of the target averaging mass and equal to 45%. In our simulations of the full brain segmentation and six simplified versions of the Freddie model, the error associated with incorrect dielectric property assignment around the DBS electrodes was greater than the error associated with modeling the whole model as a single tissue class. Our DBS patient models are freely available on our lab website (Webpage of the Martinos Center Phantom Resource 2018 https://phantoms.martinos.org/Main_Page). 
700 1 |a Davids, Mathias  |d 1989-  |e VerfasserIn  |0 (DE-588)1079252940  |0 (DE-627)840692080  |0 (DE-576)452308771  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 64(2019,3) Artikel-Nummer 035021, 14 Seiten  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a The "virtual DBS population" five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies 
773 1 8 |g volume:64  |g year:2019  |g number:3  |g extent:14  |a The "virtual DBS population" five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies 
856 4 0 |u https://doi.org/10.1088/1361-6560/aafce8  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://iopscience.iop.org/article/10.1088/1361-6560/aafce8  |x Verlag 
951 |a AR 
992 |a 20191004 
993 |a Article 
994 |a 2019 
998 |g 1079252940  |a Davids, Mathias  |m 1079252940:Davids, Mathias  |d 60000  |d 65200  |e 60000PD1079252940  |e 65200PD1079252940  |k 0/60000/  |k 1/60000/65200/  |p 3 
999 |a KXP-PPN1678145424  |e 3519522063 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1088/1361-6560/aafce8"],"eki":["1678145424"]},"origin":[{"dateIssuedDisp":"4 February 2019","dateIssuedKey":"2019"}],"name":{"displayForm":["Bastien Guerin, Maria Ida Iacono, Mathias Davids, Darin Dougherty, Leonardo M. Angelone and Lawrence L. Wald"]},"relHost":[{"recId":"269016163","language":["eng"],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"disp":"The \"virtual DBS population\" five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studiesPhysics in medicine and biology","type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"extent":"14","volume":"64","text":"64(2019,3) Artikel-Nummer 035021, 14 Seiten","issue":"3","year":"2019"},"pubHistory":["1.1956 -"],"title":[{"title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["269016163"],"zdb":["1473501-5"],"issn":["1361-6560"]},"origin":[{"publisherPlace":"Bristol","publisher":"IOP Publ.","dateIssuedKey":"1956","dateIssuedDisp":"1956-"}]}],"physDesc":[{"extent":"14 S."}],"title":[{"title":"The \"virtual DBS population\"","subtitle":"five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies","title_sort":"\"virtual DBS population\""}],"person":[{"family":"Guerin","given":"Bastien","display":"Guerin, Bastien","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Mathias","family":"Davids","role":"aut","display":"Davids, Mathias","roleDisplay":"VerfasserIn"}],"recId":"1678145424","language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 24.10.2019"]} 
SRT |a GUERINBASTVIRTUALDBS4201