An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets

PurposeIn radiation therapy, the computer-assisted deep inspiration breath-hold (DIBH) technique is one approach to deal with respiratory motion of tumors in the lung, liver, or upper abdomen. However, inter- and intra-breath-hold deviations from an optimal static tumor position might occur. A novel...

Full description

Saved in:
Bibliographic Details
Main Authors: Blessing, Manuel (Author) , Vogel, Lena (Author) , Boda-Heggemann, Judit (Author) , Wenz, Frederik (Author) , Stieler, Florian (Author) , Simeonova-Chergou, Anna (Author)
Format: Article (Journal)
Language:English
Published: 22 May 2018
In: Strahlentherapie und Onkologie
Year: 2018, Volume: 194, Issue: 9, Pages: 855-860
ISSN:1439-099X
DOI:10.1007/s00066-018-1313-3
Online Access:Verlag, Volltext: https://doi.org/10.1007/s00066-018-1313-3
Get full text
Author Notes:Manuel Blessing, Julian Hofmann, Lena Vogel, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, Florian Stieler, Anna Simeonova-Chergou

MARC

LEADER 00000caa a2200000 c 4500
001 167898325X
003 DE-627
005 20220817002313.0
007 cr uuu---uuuuu
008 191016s2018 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00066-018-1313-3  |2 doi 
035 |a (DE-627)167898325X 
035 |a (DE-599)KXP167898325X 
035 |a (OCoLC)1341248137 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Blessing, Manuel  |d 1981-  |e VerfasserIn  |0 (DE-588)1026795419  |0 (DE-627)727398385  |0 (DE-576)372120873  |4 aut 
245 1 3 |a An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets  |c Manuel Blessing, Julian Hofmann, Lena Vogel, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, Florian Stieler, Anna Simeonova-Chergou 
264 1 |c 22 May 2018 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.10.2019 
520 |a PurposeIn radiation therapy, the computer-assisted deep inspiration breath-hold (DIBH) technique is one approach to deal with respiratory motion of tumors in the lung, liver, or upper abdomen. However, inter- and intra-breath-hold deviations from an optimal static tumor position might occur. A novel method is presented to noninvasively measure the diaphragm position and thus estimate its residual deviation (as surrogate for the tumor position) based on cone-beam computed tomography (CBCT) projection data using active breathing control during acquisition.MethodsThe diaphragm dome (DD) position relative to the isocenter of a linear accelerator is known from the static (DIBH) planning CT. A ball-bearing phantom (BB) is placed at this position, a CBCT dataset is acquired, and in each projection the position of the projected BB is determined automatically based on thresholding. The position of the DD is determined manually in CBCT projections of a patient. The distance between DD and BB (ideal static setting) in craniocaudal direction is calculated for a given angle based on the distance in the projection plane and the relative position of the BB referring to the source and the detector. An angle-dependent correction factor is introduced which takes this geometrical setting into account. The accuracy of the method is assessed.ResultsThe method allows a CBCT projection-based estimation of the deviation between the DD and its optimal position as defined in the planning CT, i.e., the residual motion of the DD can be assessed. The error of this estimation is 2.2 mm in craniocaudal direction.ConclusionsThe developed method allows an offline estimation of the inspiration depth (inter- and intra-breath-hold) over time. It will be useful as a reference for comparison to other methods of residual motion estimation, e.g., surface scanning. 
650 4 |a Active breathing control 
650 4 |a Aktive Atemkontrolle 
650 4 |a Cone-beam computed tomography 
650 4 |a Cone-Beam-Computertomographie 
650 4 |a Deep inspiration breath-hold 
650 4 |a Inspiratorischer Atemanhalt 
650 4 |a Patient positioning 
650 4 |a Patientenpositionierung 
650 4 |a Residual motion 
650 4 |a Restbewegung 
700 1 |a Vogel, Lena  |d 1994-  |e VerfasserIn  |0 (DE-588)1178711447  |0 (DE-627)1049590864  |0 (DE-576)517873648  |4 aut 
700 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
700 1 |a Stieler, Florian  |d 1979-  |e VerfasserIn  |0 (DE-588)1018888055  |0 (DE-627)683440187  |0 (DE-576)354555626  |4 aut 
700 1 |a Simeonova-Chergou, Anna  |d 1980-  |e VerfasserIn  |0 (DE-588)1022879944  |0 (DE-627)71732477X  |0 (DE-576)363041532  |4 aut 
773 0 8 |i Enthalten in  |t Strahlentherapie und Onkologie  |d Berlin : Springer Medizin, 1997  |g 194(2018), 9, Seite 855-860  |h Online-Ressource  |w (DE-627)312407866  |w (DE-600)2003907-4  |w (DE-576)090884809  |x 1439-099X  |7 nnas  |a An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets 
773 1 8 |g volume:194  |g year:2018  |g number:9  |g pages:855-860  |g extent:6  |a An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets 
856 4 0 |u https://doi.org/10.1007/s00066-018-1313-3  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20191016 
993 |a Article 
994 |a 2018 
998 |g 1022879944  |a Simeonova-Chergou, Anna  |m 1022879944:Simeonova-Chergou, Anna  |d 60000  |d 63000  |e 60000PS1022879944  |e 63000PS1022879944  |k 0/60000/  |k 1/60000/63000/  |p 8  |y j 
998 |g 1018888055  |a Stieler, Florian  |m 1018888055:Stieler, Florian  |d 60000  |d 63000  |e 60000PS1018888055  |e 63000PS1018888055  |k 0/60000/  |k 1/60000/63000/  |p 7 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |e 60000PW113310390  |e 63000PW113310390  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |d 63000  |e 60000PB1029853436  |e 63000PB1029853436  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1178711447  |a Vogel, Lena  |m 1178711447:Vogel, Lena  |d 60000  |d 63000  |e 60000PV1178711447  |e 63000PV1178711447  |k 0/60000/  |k 1/60000/63000/  |p 3 
998 |g 1026795419  |a Blessing, Manuel  |m 1026795419:Blessing, Manuel  |d 60000  |d 63000  |e 60000PB1026795419  |e 63000PB1026795419  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN167898325X  |e 352323476X 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 16.10.2019"],"relHost":[{"id":{"issn":["1439-099X"],"zdb":["2003907-4"],"eki":["312407866"]},"recId":"312407866","note":["Gesehen am 13.05.09"],"language":["ger"],"title":[{"title_sort":"Strahlentherapie und Onkologie","title":"Strahlentherapie und Onkologie","subtitle":"journal of radiation oncology, biology, physics"}],"disp":"An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasetsStrahlentherapie und Onkologie","part":{"text":"194(2018), 9, Seite 855-860","year":"2018","issue":"9","extent":"6","volume":"194","pages":"855-860"},"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["Nachgewiesen 173.1997 -"],"origin":[{"dateIssuedKey":"1997","publisher":"Springer Medizin ; Urban & Vogel","dateIssuedDisp":"1997-","publisherPlace":"Berlin ; Heidelberg ; [München]"}],"physDesc":[{"extent":"Online-Ressource"}]}],"recId":"167898325X","person":[{"given":"Manuel","display":"Blessing, Manuel","family":"Blessing","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Lena","display":"Vogel, Lena","family":"Vogel","role":"aut","roleDisplay":"VerfasserIn"},{"given":"Judit","display":"Boda-Heggemann, Judit","family":"Boda-Heggemann","role":"aut","roleDisplay":"VerfasserIn"},{"given":"Frederik","roleDisplay":"VerfasserIn","role":"aut","family":"Wenz","display":"Wenz, Frederik"},{"role":"aut","roleDisplay":"VerfasserIn","family":"Stieler","display":"Stieler, Florian","given":"Florian"},{"given":"Anna","role":"aut","roleDisplay":"VerfasserIn","display":"Simeonova-Chergou, Anna","family":"Simeonova-Chergou"}],"id":{"eki":["167898325X"],"doi":["10.1007/s00066-018-1313-3"]},"name":{"displayForm":["Manuel Blessing, Julian Hofmann, Lena Vogel, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, Florian Stieler, Anna Simeonova-Chergou"]},"language":["eng"],"title":[{"title":"An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets","title_sort":"offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"6 S."}],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"22 May 2018"}]} 
SRT |a BLESSINGMAOFFLINETEC2220