Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution
We have used different metallic magnetic calorimeter (MMC) gamma detectors to measure the low-energy emissions of 233U with an accuracy of a few eV. 233U is of interest in nuclear safeguards because it is a fissile isotope that is produced by neutron irradiation of 232Th in the thorium fuel cycle. H...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
5 September 2018
|
| In: |
Journal of radioanalytical and nuclear chemistry
Year: 2018, Jahrgang: 318, Heft: 1, Pages: 803-808 |
| ISSN: | 1588-2780 |
| DOI: | 10.1007/s10967-018-6182-9 |
| Online-Zugang: | Resolving-System, Volltext: https://doi.org/10.1007/s10967-018-6182-9 Verlag: https://link.springer.com/article/10.1007%2Fs10967-018-6182-9 |
| Verfasserangaben: | Geon-Bo Kim, Ruslan Hummatov, Sebastian Kempf, Cameron Flynn, Robin Cantor, Andreas Fleischmann, Stephen T.P. Boyd, Christian Enss, Stephan Friedrich |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 167911266X | ||
| 003 | DE-627 | ||
| 005 | 20230426155202.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 191018s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s10967-018-6182-9 |2 doi | |
| 035 | |a (DE-627)167911266X | ||
| 035 | |a (DE-599)KXP167911266X | ||
| 035 | |a (OCoLC)1341248130 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Kim, Geon-Bo |e VerfasserIn |0 (DE-588)1181021170 |0 (DE-627)1662631545 |4 aut | |
| 245 | 1 | 0 | |a Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution |c Geon-Bo Kim, Ruslan Hummatov, Sebastian Kempf, Cameron Flynn, Robin Cantor, Andreas Fleischmann, Stephen T.P. Boyd, Christian Enss, Stephan Friedrich |
| 246 | 3 | 0 | |a U-233 U 233 |
| 246 | 3 | 3 | |a Consistent measurements of 233 U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution |
| 264 | 1 | |c 5 September 2018 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Im Titel ist die Zahl 233 hochgestellt | ||
| 500 | |a Gesehen am 18.10.2019 | ||
| 520 | |a We have used different metallic magnetic calorimeter (MMC) gamma detectors to measure the low-energy emissions of 233U with an accuracy of a few eV. 233U is of interest in nuclear safeguards because it is a fissile isotope that is produced by neutron irradiation of 232Th in the thorium fuel cycle. However, some of the nuclear decay data of 233U in the literature have relatively high uncertainties, especially at lower energies where lines can overlap or be dominated by a high Compton background. MMC gamma detectors operated at a temperature of 10 mK can have an energy resolution below 50 eV and can resolve lines with similar energy and reduce these uncertainties. We present recent MMC measurements of 233U and discuss the contributions of statistical and systematic errors. Importantly, we have performed the experiments with different MMC gamma detectors and different SQUID readout systems to increase the confidence in some observed deviations from literature values. The consistency of the results suggest that observed deviations are not due to detector artifacts and that a predictable quadratic response is intrinsic to the properties of MMCs. | ||
| 650 | 4 | |a Cryogenic microcalorimeter | |
| 650 | 4 | |a Gamma spectroscopy | |
| 650 | 4 | |a High energy resolution | |
| 650 | 4 | |a Metallic magnetic calorimeter | |
| 650 | 4 | |a MMC | |
| 650 | 4 | |a Uranium-233 | |
| 700 | 1 | |a Kempf, Sebastian |d 1983- |e VerfasserIn |0 (DE-588)1020440449 |0 (DE-627)69122143X |0 (DE-576)360448690 |4 aut | |
| 700 | 1 | |a Fleischmann, Andreas |e VerfasserIn |0 (DE-588)1020467568 |0 (DE-627)691226873 |0 (DE-576)360449409 |4 aut | |
| 700 | 1 | |a Enss, Christian |d 1960- |e VerfasserIn |0 (DE-588)1020467878 |0 (DE-627)691227020 |0 (DE-576)360449530 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of radioanalytical and nuclear chemistry |d Dordrecht [u.a.] : Springer Science + Business Media B.V., 1968 |g 318(2018), 1, Seite 803-808 |h Online-Ressource |w (DE-627)320578011 |w (DE-600)2017242-4 |w (DE-576)121466175 |x 1588-2780 |7 nnas |a Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution |
| 773 | 1 | 8 | |g volume:318 |g year:2018 |g number:1 |g pages:803-808 |g extent:6 |a Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10967-018-6182-9 |x Resolving-System |x Verlag |3 Volltext |
| 856 | 4 | 0 | |u https://link.springer.com/article/10.1007%2Fs10967-018-6182-9 |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20191018 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 1020467878 |a Enss, Christian |m 1020467878:Enss, Christian |d 130000 |d 130700 |e 130000PE1020467878 |e 130700PE1020467878 |k 0/130000/ |k 1/130000/130700/ |p 8 | ||
| 998 | |g 1020467568 |a Fleischmann, Andreas |m 1020467568:Fleischmann, Andreas |d 130000 |d 130700 |e 130000PF1020467568 |e 130700PF1020467568 |k 0/130000/ |k 1/130000/130700/ |p 6 | ||
| 998 | |g 1020440449 |a Kempf, Sebastian |m 1020440449:Kempf, Sebastian |d 130000 |d 130700 |e 130000PK1020440449 |e 130700PK1020440449 |k 0/130000/ |k 1/130000/130700/ |p 3 | ||
| 999 | |a KXP-PPN167911266X |e 3524308295 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"family":"Kim","display":"Kim, Geon-Bo","given":"Geon-Bo","role":"aut"},{"display":"Kempf, Sebastian","family":"Kempf","given":"Sebastian","role":"aut"},{"role":"aut","family":"Fleischmann","display":"Fleischmann, Andreas","given":"Andreas"},{"family":"Enss","display":"Enss, Christian","given":"Christian","role":"aut"}],"titleAlt":[{"title":"Consistent measurements of 233 U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution"}],"title":[{"title_sort":"Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution","title":"Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolution"}],"physDesc":[{"extent":"6 S."}],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"5 September 2018"}],"name":{"displayForm":["Geon-Bo Kim, Ruslan Hummatov, Sebastian Kempf, Cameron Flynn, Robin Cantor, Andreas Fleischmann, Stephen T.P. Boyd, Christian Enss, Stephan Friedrich"]},"note":["Im Titel ist die Zahl 233 hochgestellt","Gesehen am 18.10.2019"],"recId":"167911266X","relHost":[{"disp":"Consistent measurements of 233U gamma emissions using metallic magnetic calorimeters with ultra-high energy resolutionJournal of radioanalytical and nuclear chemistry","note":["Gesehen am 18.03.25"],"pubHistory":["Volume 81, issue 1 (January 1984)-"],"recId":"320578011","type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"issn":["1588-2780"],"zdb":["2017242-4"],"eki":["320578011"]},"language":["eng"],"origin":[{"publisherPlace":"Dordrecht [u.a.] ; Dordrecht [u.a.] ; Amsterdam [u.a.]","dateIssuedDisp":"1968-","dateIssuedKey":"1968","publisher":"Springer Science + Business Media B.V. ; Kluwer ; Elsevier Science"}],"title":[{"title":"Journal of radioanalytical and nuclear chemistry","subtitle":"an international journal dealing with all aspects and applications of nuclear chemistry","title_sort":"Journal of radioanalytical and nuclear chemistry"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"volume":"318","text":"318(2018), 1, Seite 803-808","pages":"803-808","extent":"6","year":"2018","issue":"1"}}],"id":{"eki":["167911266X"],"doi":["10.1007/s10967-018-6182-9"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"}} | ||
| SRT | |a KIMGEONBOKCONSISTENT5201 | ||