Auto-calibration by locally consistent contours for dental CBCT

The image quality of dental cone-beam computed tomography (CBCT) is limited by the accuracy of device calibration. Inaccurate calibration introduces errors in the reconstruction process, which may lead to severe artifacts in the reconstructed volume. Patient motion during scan acquisition induces si...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Maur, Susanne (VerfasserIn) , Stsepankou, Dzmitry (VerfasserIn) , Hesser, Jürgen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29 October 2018
In: Physics in medicine and biology
Year: 2018, Jahrgang: 63, Heft: 21
ISSN:1361-6560
DOI:10.1088/1361-6560/aae66d
Online-Zugang:Verlag, Volltext: https://doi.org/10.1088/1361-6560/aae66d
Volltext
Verfasserangaben:S. Maur, D. Stsepankou, J. Hesser

MARC

LEADER 00000caa a2200000 c 4500
001 167912255X
003 DE-627
005 20230426155203.0
007 cr uuu---uuuuu
008 191018s2018 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/aae66d  |2 doi 
035 |a (DE-627)167912255X 
035 |a (DE-599)KXP167912255X 
035 |a (OCoLC)1341248248 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Maur, Susanne  |d 1984-  |e VerfasserIn  |0 (DE-588)1197554912  |0 (DE-627)1679223070  |4 aut 
245 1 0 |a Auto-calibration by locally consistent contours for dental CBCT  |c S. Maur, D. Stsepankou, J. Hesser 
264 1 |c 29 October 2018 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.10.2019 
520 |a The image quality of dental cone-beam computed tomography (CBCT) is limited by the accuracy of device calibration. Inaccurate calibration introduces errors in the reconstruction process, which may lead to severe artifacts in the reconstructed volume. Patient motion during scan acquisition induces similar effects. This paper introduces a novel auto-calibration approach calculating geometrical projection parameters from unknown patient geometry. We formulate consistency conditions linking the information of consecutive projection images and a regularization technique to prevent overall distortions. Implemented as a global optimization problem we present an efficient greedy optimizer as well. Our strategy turns out to be robust towards inaccurate initialization. As our method does not rely on consistency between projection data and tomography reconstruction it is robust towards reconstruction artifacts such as e.g. truncation. Applying our approach for auto-calibration shows a relative improvement of sharpness up to of in a standard dental CBCT setup. Evaluation is performed on digital reconstructed radiographs (DRRs) of a CT head-scan. In particular different motion types are considered and the number of anatomical structures used for calibration is varied to achieve an understanding of the behavior of the approach. 
700 1 |a Stsepankou, Dzmitry  |d 1976-  |e VerfasserIn  |0 (DE-588)1020647663  |0 (DE-627)69129125X  |0 (DE-576)361517831  |4 aut 
700 1 |a Hesser, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1020647353  |0 (DE-627)691291071  |0 (DE-576)361513739  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 63 (2018,21) Artikel-Nummer 215018, Seite 1-12, 12 Seiten  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Auto-calibration by locally consistent contours for dental CBCT 
773 1 8 |g volume:63  |g year:2018  |g number:21  |g extent:12  |a Auto-calibration by locally consistent contours for dental CBCT 
856 4 0 |u https://doi.org/10.1088/1361-6560/aae66d  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20191018 
993 |a Article 
994 |a 2018 
998 |g 1020647353  |a Hesser, Jürgen  |m 1020647353:Hesser, Jürgen  |d 60000  |d 63000  |e 60000PH1020647353  |e 63000PH1020647353  |k 0/60000/  |k 1/60000/63000/  |p 3  |y j 
998 |g 1020647663  |a Stsepankou, Dzmitry  |m 1020647663:Stsepankou, Dzmitry  |d 60000  |d 63000  |e 60000PS1020647663  |e 63000PS1020647663  |k 0/60000/  |k 1/60000/63000/  |p 2 
999 |a KXP-PPN167912255X  |e 3524333346 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","given":"Susanne","display":"Maur, Susanne","family":"Maur"},{"given":"Dzmitry","role":"aut","display":"Stsepankou, Dzmitry","family":"Stsepankou"},{"display":"Hesser, Jürgen","family":"Hesser","given":"Jürgen","role":"aut"}],"language":["eng"],"title":[{"title":"Auto-calibration by locally consistent contours for dental CBCT","title_sort":"Auto-calibration by locally consistent contours for dental CBCT"}],"note":["Gesehen am 18.10.2019"],"origin":[{"dateIssuedDisp":"29 October 2018","dateIssuedKey":"2018"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"167912255X","name":{"displayForm":["S. Maur, D. Stsepankou, J. Hesser"]},"physDesc":[{"extent":"12 S."}],"relHost":[{"id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]},"recId":"269016163","pubHistory":["1.1956 -"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"part":{"year":"2018","issue":"21","text":"63 (2018,21) Artikel-Nummer 215018, Seite 1-12, 12 Seiten","extent":"12","volume":"63"},"origin":[{"publisherPlace":"Bristol","dateIssuedDisp":"1956-","publisher":"IOP Publ.","dateIssuedKey":"1956"}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology"}],"disp":"Auto-calibration by locally consistent contours for dental CBCTPhysics in medicine and biology"}],"id":{"eki":["167912255X"],"doi":["10.1088/1361-6560/aae66d"]}} 
SRT |a MAURSUSANNAUTOCALIBR2920