Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom

With high-precision radiotherapy on the rise towards mainstream healthcare, comprehensive validation procedures are essential, especially as more sophisticated technologies emerge. In preparation for the upcoming translation of novel ions, case-/disease-specific ion-beam selection and advanced multi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mein, Stewart (VerfasserIn) , Bauer, Julia (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Abdollahi, Amir (VerfasserIn) , Mairani, Andrea (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 July 2019
In: Physica medica
Year: 2019, Jahrgang: 64, Pages: 123-131
ISSN:1724-191X
DOI:10.1016/j.ejmp.2019.07.001
Online-Zugang:Verlag, Volltext: https://doi.org/10.1016/j.ejmp.2019.07.001
Verlag: http://www.sciencedirect.com/science/article/pii/S1120179719301541
Volltext
Verfasserangaben:Stewart Mein, Benedikt Kopp, Thomas Tessonnier, Benjamin Ackermann, Swantje Ecker, Julia Bauer, Kyungdon Choi, Giulia Aricò, Alfredo Ferrari, Thomas Haberer, Jürgen Debus, Amir Abdollahi, Andrea Mairani

MARC

LEADER 00000caa a2200000 c 4500
001 1679193066
003 DE-627
005 20230426155219.0
007 cr uuu---uuuuu
008 191021s2019 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejmp.2019.07.001  |2 doi 
035 |a (DE-627)1679193066 
035 |a (DE-599)KXP1679193066 
035 |a (OCoLC)1341248147 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mein, Stewart  |d 1989-  |e VerfasserIn  |0 (DE-588)1156925304  |0 (DE-627)1019871873  |0 (DE-576)502506105  |4 aut 
245 1 0 |a Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom  |c Stewart Mein, Benedikt Kopp, Thomas Tessonnier, Benjamin Ackermann, Swantje Ecker, Julia Bauer, Kyungdon Choi, Giulia Aricò, Alfredo Ferrari, Thomas Haberer, Jürgen Debus, Amir Abdollahi, Andrea Mairani 
246 3 3 |a Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1 H, 4 He, 12 C, and 16 O ion-beams using an anthropomorphic phantom 
264 1 |c 11 July 2019 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.10.2019 
500 |a Im Titel sind die Zahlen 1, 4, 12 und 16 hochgestellt 
520 |a With high-precision radiotherapy on the rise towards mainstream healthcare, comprehensive validation procedures are essential, especially as more sophisticated technologies emerge. In preparation for the upcoming translation of novel ions, case-/disease-specific ion-beam selection and advanced multi-particle treatment modalities at the Heidelberg Ion-beam Therapy Center (HIT), we quantify the accuracy limits in particle therapy treatment planning under complex heterogeneous conditions for the four ions (1H, 4He, 12C, 16O) using a Monte Carlo Treatment Planning platform (MCTP), an independent GPU-accelerated analytical dose engine developed in-house (FRoG) and the clinical treatment planning system (Syngo RT Planning). Attaching an anthropomorphic half-head Alderson RANDO phantom to entrance window of a dosimetric verification water tank, a cubic target spread-out Bragg peak (SOBP) was optimized using the MCTP to best resolve effects of anatomic heterogeneities on dose homogeneity. Subsequent forward calculations were executed in FRoG and Syngo. Absolute and relative dosimetry was performed in the experimental beam room using 1D and 2D array ionization chamber detectors. Mean absolute percent deviation in dose (|%Δ|) between predictions and PinPoint ionization chamber measurements were within ∼2% for all investigated ions for both MCTP and FRoG. For protons and carbon ions, |%Δ| values were ∼4% for Syngo. For the four ions, 3D-γ analysis (3%/3mm criteria) of FLUKA and FRoG presented mean passing rates of 97.0(±2.4)% and 93.6(±4.2)%. FRoG demonstrated satisfactory agreement with gold standard Monte Carlo simulation and measurement, superior to the commercial system. Our pre-clinical trial landmarks the first measurements taken in anthropomorphic settings for helium, carbon and oxygen ion-beam therapy. 
650 4 |a Anthropomorphic phantom 
650 4 |a Dosimetry 
650 4 |a GPU 
650 4 |a Monte Carlo simulation 
650 4 |a Particle therapy 
650 4 |a Pencil beam algorithm 
700 1 |a Bauer, Julia  |e VerfasserIn  |0 (DE-588)107489099X  |0 (DE-627)832650145  |0 (DE-576)443090904  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Abdollahi, Amir  |e VerfasserIn  |0 (DE-588)129612715  |0 (DE-627)474757765  |0 (DE-576)297748874  |4 aut 
700 1 |a Mairani, Andrea  |e VerfasserIn  |0 (DE-588)1116742179  |0 (DE-627)870669281  |0 (DE-576)478592493  |4 aut 
773 0 8 |i Enthalten in  |t Physica medica  |d Amsterdam : Elsevier, 1996  |g 64(2019), Seite 123-131  |h Online-Ressource  |w (DE-627)364471417  |w (DE-600)2110535-2  |w (DE-576)272350176  |x 1724-191X  |7 nnas  |a Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom 
773 1 8 |g volume:64  |g year:2019  |g pages:123-131  |g extent:9  |a Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom 
856 4 0 |u https://doi.org/10.1016/j.ejmp.2019.07.001  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1120179719301541  |x Verlag 
951 |a AR 
992 |a 20191021 
993 |a Article 
994 |a 2019 
998 |g 1116742179  |a Mairani, Andrea  |m 1116742179:Mairani, Andrea  |d 910000  |d 950000  |d 950400  |e 910000PM1116742179  |e 950000PM1116742179  |e 950400PM1116742179  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 13  |y j 
998 |g 129612715  |a Abdollahi, Amir  |m 129612715:Abdollahi, Amir  |d 910000  |d 911400  |e 910000PA129612715  |e 911400PA129612715  |k 0/910000/  |k 1/910000/911400/  |p 12 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 11 
998 |g 107489099X  |a Bauer, Julia  |m 107489099X:Bauer, Julia  |d 910000  |d 911400  |e 910000PB107489099X  |e 911400PB107489099X  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1156925304  |a Mein, Stewart  |m 1156925304:Mein, Stewart  |d 130000  |e 130000PM1156925304  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1679193066  |e 3525701373 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1016/j.ejmp.2019.07.001"],"eki":["1679193066"]},"name":{"displayForm":["Stewart Mein, Benedikt Kopp, Thomas Tessonnier, Benjamin Ackermann, Swantje Ecker, Julia Bauer, Kyungdon Choi, Giulia Aricò, Alfredo Ferrari, Thomas Haberer, Jürgen Debus, Amir Abdollahi, Andrea Mairani"]},"titleAlt":[{"title":"Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1 H, 4 He, 12 C, and 16 O ion-beams using an anthropomorphic phantom"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 21.10.2019","Im Titel sind die Zahlen 1, 4, 12 und 16 hochgestellt"],"title":[{"title_sort":"Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom","title":"Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom"}],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"11 July 2019"}],"relHost":[{"pubHistory":["Nachgewiesen 12.1996 -"],"origin":[{"publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedKey":"1996","publisherPlace":"Amsterdam ; Pisa","dateIssuedDisp":"1996-"}],"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title_sort":"Physica medica","title":"Physica medica","subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology"}],"part":{"year":"2019","pages":"123-131","extent":"9","text":"64(2019), Seite 123-131","volume":"64"},"id":{"zdb":["2110535-2"],"issn":["1724-191X"],"eki":["364471417"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"364471417","disp":"Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantomPhysica medica"}],"person":[{"display":"Mein, Stewart","family":"Mein","given":"Stewart","role":"aut"},{"display":"Bauer, Julia","family":"Bauer","given":"Julia","role":"aut"},{"display":"Debus, Jürgen","given":"Jürgen","role":"aut","family":"Debus"},{"display":"Abdollahi, Amir","role":"aut","given":"Amir","family":"Abdollahi"},{"family":"Mairani","given":"Andrea","role":"aut","display":"Mairani, Andrea"}],"physDesc":[{"extent":"9 S."}],"recId":"1679193066"} 
SRT |a MEINSTEWARDOSIMETRIC1120