Pulmonary valve prosthesis endocarditis caused by Coxiella burnetii

Background: Coxiella burnetii is a gram-negative bacterium assigned to the family of Rickettsiaceae. Less than 1% of Q-fever infection leads to infective endocarditis (IE). Cases of reported pulmonary valve (PV) prosthesis endocarditis are scarce. Case Description: A patient with a PV prosthesis end...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kremer, Jamila (VerfasserIn) , Mutters, Nico T. (VerfasserIn) , Karck, Matthias (VerfasserIn) , Last, Katharina (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29. November 2018
In: The thoracic and cardiovascular surgeon reports
Year: 2018, Jahrgang: 7, Heft: 1, Pages: e47-e49
ISSN:2194-7643
DOI:10.1055/s-0038-1675841
Online-Zugang:Verlag, Volltext: https://doi.org/10.1055/s-0038-1675841
Verlag: http://www.thieme-connect.de/DOI/DOI?10.1055/s-0038-1675841
Volltext
Verfasserangaben:Jamila Kremer, Nico Tom Mutters, Matthias Karck, Katharina Last

MARC

LEADER 00000caa a2200000 c 4500
001 1680547038
003 DE-627
005 20240918072321.0
007 cr uuu---uuuuu
008 191029s2018 xx |||||o 00| ||eng c
024 7 |a 10.1055/s-0038-1675841  |2 doi 
035 |a (DE-627)1680547038 
035 |a (DE-599)KXP1680547038 
035 |a (OCoLC)1341249544 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kremer, Jamila  |d 1988-  |e VerfasserIn  |0 (DE-588)1139366769  |0 (DE-627)897130081  |0 (DE-576)493242287  |4 aut 
245 1 0 |a Pulmonary valve prosthesis endocarditis caused by Coxiella burnetii  |c Jamila Kremer, Nico Tom Mutters, Matthias Karck, Katharina Last 
264 1 |c 29. November 2018 
300 |a 3 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.10.2019 
520 |a Background: Coxiella burnetii is a gram-negative bacterium assigned to the family of Rickettsiaceae. Less than 1% of Q-fever infection leads to infective endocarditis (IE). Cases of reported pulmonary valve (PV) prosthesis endocarditis are scarce. Case Description: A patient with a PV prosthesis endocarditis caused by Coxiella burnetii was seeking asylum in Germany. Prosthesis replacement was performed. All obtained blood cultures showed no growth as well as microbiological cultures of the prosthetic valve tissue. A polymerase chain reaction analysis on the explanted prosthesis detected DNA of Coxiella spp. Conclusion: Diagnosing IE caused by Coxiella burnetii requires an interdisciplinary effort from both clinicians and microbiologists. 
700 1 |a Mutters, Nico T.  |d 1980-  |e VerfasserIn  |0 (DE-588)136849687  |0 (DE-627)694710199  |0 (DE-576)288598962  |4 aut 
700 1 |a Karck, Matthias  |d 1961-  |e VerfasserIn  |0 (DE-588)130833525  |0 (DE-627)505909340  |0 (DE-576)298366169  |4 aut 
700 1 |a Last, Katharina  |d 1985-  |e VerfasserIn  |0 (DE-588)1191851257  |0 (DE-627)1670326632  |4 aut 
773 0 8 |i Enthalten in  |t The thoracic and cardiovascular surgeon reports  |d Stuttgart : Thieme, 2012  |g 7(2018), 1, Seite e47-e49  |h Online-Ressource  |w (DE-627)737829052  |w (DE-600)2706759-2  |w (DE-576)379972077  |x 2194-7643  |7 nnas  |a Pulmonary valve prosthesis endocarditis caused by Coxiella burnetii 
773 1 8 |g volume:7  |g year:2018  |g number:1  |g pages:e47-e49  |g extent:3  |a Pulmonary valve prosthesis endocarditis caused by Coxiella burnetii 
856 4 0 |u https://doi.org/10.1055/s-0038-1675841  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.thieme-connect.de/DOI/DOI?10.1055/s-0038-1675841  |x Verlag 
951 |a AR 
992 |a 20191029 
993 |a Article 
994 |a 2018 
998 |g 1191851257  |a Last, Katharina  |m 1191851257:Last, Katharina  |d 910000  |d 911700  |e 910000PL1191851257  |e 911700PL1191851257  |k 0/910000/  |k 1/910000/911700/  |p 4  |y j 
998 |g 130833525  |a Karck, Matthias  |m 130833525:Karck, Matthias  |d 910000  |d 910200  |e 910000PK130833525  |e 910200PK130833525  |k 0/910000/  |k 1/910000/910200/  |p 3 
998 |g 136849687  |a Mutters, Nico T.  |m 136849687:Mutters, Nico T.  |d 910000  |d 911700  |e 910000PM136849687  |e 911700PM136849687  |k 0/910000/  |k 1/910000/911700/  |p 2 
998 |g 1139366769  |a Kremer, Jamila  |m 1139366769:Kremer, Jamila  |d 910000  |d 910200  |e 910000PK1139366769  |e 910200PK1139366769  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1680547038  |e 353082013X 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Pulmonary valve prosthesis endocarditis caused by Coxiella burnetii","title_sort":"Pulmonary valve prosthesis endocarditis caused by Coxiella burnetii"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 29.10.2019"],"origin":[{"dateIssuedDisp":"29. November 2018","dateIssuedKey":"2018"}],"relHost":[{"pubHistory":["1.2012 -"],"corporate":[{"role":"isb","display":"Deutsche Gesellschaft für Thorax-, Herz- und Gefäßchirurgie"}],"id":{"doi":["10.1055/s-00024355"],"zdb":["2706759-2"],"eki":["737829052"],"issn":["2194-7643"]},"part":{"text":"7(2018), 1, Seite e47-e49","extent":"3","issue":"1","pages":"e47-e49","volume":"7","year":"2018"},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012-","publisherPlace":"Stuttgart","publisher":"Thieme"}],"title":[{"title":"The thoracic and cardiovascular surgeon reports","title_sort":"thoracic and cardiovascular surgeon reports","subtitle":"official organ of the German Society for Thoracic and Cardiovascular Surgery"}],"language":["ger","eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 17.12.18","Fortsetzung der Druck-Ausgabe"],"recId":"737829052","physDesc":[{"extent":"Online-Ressource"}],"disp":"Pulmonary valve prosthesis endocarditis caused by Coxiella burnetiiThe thoracic and cardiovascular surgeon reports"}],"person":[{"role":"aut","given":"Jamila","family":"Kremer","display":"Kremer, Jamila"},{"family":"Mutters","role":"aut","given":"Nico T.","display":"Mutters, Nico T."},{"display":"Karck, Matthias","given":"Matthias","role":"aut","family":"Karck"},{"display":"Last, Katharina","family":"Last","role":"aut","given":"Katharina"}],"recId":"1680547038","physDesc":[{"extent":"3 S."}],"id":{"doi":["10.1055/s-0038-1675841"],"eki":["1680547038"]},"name":{"displayForm":["Jamila Kremer, Nico Tom Mutters, Matthias Karck, Katharina Last"]}} 
SRT |a KREMERJAMIPULMONARYV2920