Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension

ObjectivesTo assess the diagnostic accuracy of automated 3D volumetry of central pulmonary arteries using computed tomography pulmonary angiography (CTPA) for suspected pulmonary hypertension alone and in combination with echocardiography.MethodsThis retrospective diagnostic accuracy study included...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Melzig, Claudius (VerfasserIn) , Wörz, Stefan (VerfasserIn) , Egenlauf, Benjamin (VerfasserIn) , Partovi, Sasan (VerfasserIn) , Rohr, Karl (VerfasserIn) , Grünig, Ekkehard (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Heußel, Claus Peter (VerfasserIn) , Rengier, Fabian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [November 2019]
In: European radiology
Year: 2019, Jahrgang: 29, Heft: 11, Pages: 6059-6068
ISSN:1432-1084
DOI:10.1007/s00330-019-06188-7
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s00330-019-06188-7
Volltext
Verfasserangaben:Claudius Melzig, Stefan Wörz, Benjamin Egenlauf, Sasan Partovi, Karl Rohr, Ekkehard Grünig, Hans-Ulrich Kauczor, Claus Peter Heussel, Fabian Rengier

MARC

LEADER 00000caa a2200000 c 4500
001 1681406578
003 DE-627
005 20220817021030.0
007 cr uuu---uuuuu
008 191107s2019 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-019-06188-7  |2 doi 
035 |a (DE-627)1681406578 
035 |a (DE-599)KXP1681406578 
035 |a (OCoLC)1341250454 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Melzig, Claudius  |d 1986-  |e VerfasserIn  |0 (DE-588)1072780445  |0 (DE-627)828231389  |0 (DE-576)434238570  |4 aut 
245 1 0 |a Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension  |c Claudius Melzig, Stefan Wörz, Benjamin Egenlauf, Sasan Partovi, Karl Rohr, Ekkehard Grünig, Hans-Ulrich Kauczor, Claus Peter Heussel, Fabian Rengier 
264 1 |c [November 2019] 
300 |b Illustrationen 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First online: 08 April 2019 
500 |a Gesehen am 07.11.2019 
520 |a ObjectivesTo assess the diagnostic accuracy of automated 3D volumetry of central pulmonary arteries using computed tomography pulmonary angiography (CTPA) for suspected pulmonary hypertension alone and in combination with echocardiography.MethodsThis retrospective diagnostic accuracy study included 70 patients (mean age 66.7, 48 female) assessed for pulmonary hypertension by CTPA and transthoracic echocardiography with estimation of the pulmonary arterial systolic pressure (PASP). Gold standard right heart catheterisation with measurement of the invasive mean pulmonary arterial pressure (invasive mPAP) served as the reference. Volumes of the main, right and left pulmonary arteries (MPA, RPA and LPA) were computed using automated 3D segmentation. For comparison, axial dimensions were manually measured. A linear regression model was established for prediction of mPAP (predicted mPAP).ResultsMPA, RPA and LPA volumes were significantly increased in patients with vs. without pulmonary hypertension (all p < 0.001). Of all measures, MPA volume demonstrated the strongest correlation with invasive mPAP (r = 0.76, p < 0.001). Predicted mPAP using MPA volume and echocardiographic PASP as covariates showed excellent correlation with invasive mPAP (r = 0.89, p < 0.001). Area under the curves for predicting pulmonary hypertension were 0.94 for predicted mPAP, compared to 0.90 for MPA volume and 0.92 for echocardiographic PASP alone. A predicted mPAP > 25.8 mmHg identified pulmonary hypertension with sensitivity, specificity, positive and negative predictive values of 86%, 93%, 95% and 81%, respectively.ConclusionsAutomated 3D volumetry of central pulmonary arteries based on CTPA may be used in conjunction with echocardiographic pressure estimates to noninvasively predict mPAP and pulmonary hypertension as confirmed by gold standard right heart catheterisation with higher diagnostic accuracy than either test alone.Key Points • This diagnostic accuracy study derived a regression model for noninvasive prediction of invasively measured mean pulmonary arterial pressure as assessed by gold standard right heart catheterisation. • This regression model using automated 3D volumetry of the central pulmonary arteries based on CT pulmonary angiography in conjunction with the echocardiographic pressure estimate predicted pulmonary arterial pressure and the presence of pulmonary hypertension with good diagnostic accuracy. • The combination of automated 3D volumetry and echocardiographic pressure estimate in the regression model provided superior diagnostic accuracy compared to each parameter alone. 
650 4 |a Computed tomography angiography 
650 4 |a Pulmonary arteries 
650 4 |a Pulmonary artery pressure 
650 4 |a Pulmonary artery volumetry 
650 4 |a Pulmonary hypertension 
700 1 |a Wörz, Stefan  |e VerfasserIn  |0 (DE-588)173874207  |0 (DE-627)698775953  |0 (DE-576)134712765  |4 aut 
700 1 |a Egenlauf, Benjamin  |d 1978-  |e VerfasserIn  |0 (DE-588)14348091X  |0 (DE-627)646571001  |0 (DE-576)337293449  |4 aut 
700 1 |a Partovi, Sasan  |d 1986-  |e VerfasserIn  |0 (DE-588)1019808713  |0 (DE-627)687017564  |0 (DE-576)358894794  |4 aut 
700 1 |a Rohr, Karl  |e VerfasserIn  |0 (DE-588)137474466  |0 (DE-627)695829440  |0 (DE-576)303788593  |4 aut 
700 1 |a Grünig, Ekkehard  |e VerfasserIn  |0 (DE-588)112535801  |0 (DE-627)618892605  |0 (DE-576)31856694X  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Heußel, Claus Peter  |e VerfasserIn  |0 (DE-588)1048631389  |0 (DE-627)780769422  |0 (DE-576)40288146X  |4 aut 
700 1 |a Rengier, Fabian  |d 1986-  |e VerfasserIn  |0 (DE-588)139065865  |0 (DE-627)608103284  |0 (DE-576)309935873  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 29(2019), 11, Seite 6059-6068  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension 
773 1 8 |g volume:29  |g year:2019  |g number:11  |g pages:6059-6068  |g extent:10  |a Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension 
856 4 0 |u https://doi.org/10.1007/s00330-019-06188-7  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20191107 
993 |a Article 
994 |a 2019 
998 |g 139065865  |a Rengier, Fabian  |m 139065865:Rengier, Fabian  |d 910000  |d 911400  |e 910000PR139065865  |e 911400PR139065865  |k 0/910000/  |k 1/910000/911400/  |p 9  |y j 
998 |g 1048631389  |a Heußel, Claus Peter  |m 1048631389:Heußel, Claus Peter  |d 910000  |d 950000  |d 950900  |d 50000  |e 910000PH1048631389  |e 950000PH1048631389  |e 950900PH1048631389  |e 50000PH1048631389  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |k 0/50000/  |p 8 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 112535801  |a Grünig, Ekkehard  |m 112535801:Grünig, Ekkehard  |d 910000  |d 950000  |d 950900  |e 910000PG112535801  |e 950000PG112535801  |e 950900PG112535801  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 6 
998 |g 137474466  |a Rohr, Karl  |m 137474466:Rohr, Karl  |d 160000  |d 160100  |e 160000PR137474466  |e 160100PR137474466  |k 0/160000/  |k 1/160000/160100/  |p 5 
998 |g 14348091X  |a Egenlauf, Benjamin  |m 14348091X:Egenlauf, Benjamin  |d 910000  |d 950000  |d 950900  |e 910000PE14348091X  |e 950000PE14348091X  |e 950900PE14348091X  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 3 
998 |g 173874207  |a Wörz, Stefan  |m 173874207:Wörz, Stefan  |d 110000  |e 110000PW173874207  |k 0/110000/  |p 2 
998 |g 1072780445  |a Melzig, Claudius  |m 1072780445:Melzig, Claudius  |d 910000  |d 911400  |e 910000PM1072780445  |e 911400PM1072780445  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1681406578  |e 3538323763 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1681406578","physDesc":[{"noteIll":"Illustrationen","extent":"10 S."}],"title":[{"title_sort":"Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension","title":"Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["First online: 08 April 2019","Gesehen am 07.11.2019"],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"[November 2019]"}],"relHost":[{"part":{"extent":"10","text":"29(2019), 11, Seite 6059-6068","issue":"11","pages":"6059-6068","volume":"29","year":"2019"},"id":{"issn":["1432-1084","1613-3757"],"eki":["268757526"],"zdb":["1472718-3"]},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"pubHistory":["1.1991 -"],"corporate":[{"role":"isb","display":"European Association of Radiology"}],"disp":"Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertensionEuropean radiology","recId":"268757526","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"European radiology","title":"European radiology","subtitle":"official organ of the European Association of Radiology"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"origin":[{"publisher":"Springer","dateIssuedKey":"1991","publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1991-"}]}],"person":[{"display":"Melzig, Claudius","family":"Melzig","given":"Claudius","role":"aut"},{"display":"Wörz, Stefan","family":"Wörz","role":"aut","given":"Stefan"},{"display":"Egenlauf, Benjamin","family":"Egenlauf","given":"Benjamin","role":"aut"},{"display":"Partovi, Sasan","family":"Partovi","role":"aut","given":"Sasan"},{"display":"Rohr, Karl","role":"aut","given":"Karl","family":"Rohr"},{"display":"Grünig, Ekkehard","given":"Ekkehard","role":"aut","family":"Grünig"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","given":"Hans-Ulrich","role":"aut"},{"display":"Heußel, Claus Peter","role":"aut","given":"Claus Peter","family":"Heußel"},{"family":"Rengier","given":"Fabian","role":"aut","display":"Rengier, Fabian"}],"id":{"doi":["10.1007/s00330-019-06188-7"],"eki":["1681406578"]},"name":{"displayForm":["Claudius Melzig, Stefan Wörz, Benjamin Egenlauf, Sasan Partovi, Karl Rohr, Ekkehard Grünig, Hans-Ulrich Kauczor, Claus Peter Heussel, Fabian Rengier"]}} 
SRT |a MELZIGCLAUCOMBINEDAU2019