Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach

Purpose To compare gradient echo (GRE) and gradient echo sampling of spin echo (GESSE) sequences for the quantification of the oxygen extraction fraction (OEF) from combined quantitative BOLD and quantitative susceptibility mapping (QSM) with regard to accuracy, precision and parameter initializatio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hubertus, Simon Ralph (VerfasserIn) , Thomas, Sebastian (VerfasserIn) , Cho, Junghun (VerfasserIn) , Zhang, Shun (VerfasserIn) , Wang, Yi (VerfasserIn) , Schad, Lothar R. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 02 June 2019
In: Magnetic resonance in medicine
Year: 2019, Jahrgang: 82, Heft: 4, Pages: 1491-1503
ISSN:1522-2594
DOI:10.1002/mrm.27804
Online-Zugang:Verlag, Volltext: https://doi.org/10.1002/mrm.27804
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.27804
Volltext
Verfasserangaben:Simon Hubertus, Sebastian Thomas, Junghun Cho, Shun Zhang, Yi Wang, Lothar Rudi Schad

MARC

LEADER 00000caa a2200000 c 4500
001 1682125688
003 DE-627
005 20230428191336.0
007 cr uuu---uuuuu
008 191119s2019 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.27804  |2 doi 
035 |a (DE-627)1682125688 
035 |a (DE-599)KXP1682125688 
035 |a (OCoLC)1341275377 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hubertus, Simon Ralph  |d 1993-  |e VerfasserIn  |0 (DE-588)1199573892  |0 (DE-627)1681890836  |4 aut 
245 1 0 |a Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach  |c Simon Hubertus, Sebastian Thomas, Junghun Cho, Shun Zhang, Yi Wang, Lothar Rudi Schad 
264 1 |c 02 June 2019 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.11.2019 
520 |a Purpose To compare gradient echo (GRE) and gradient echo sampling of spin echo (GESSE) sequences for the quantification of the oxygen extraction fraction (OEF) from combined quantitative BOLD and quantitative susceptibility mapping (QSM) with regard to accuracy, precision and parameter initialization. Methods GRE and GESSE data were acquired from 7 healthy volunteers. QSM was applied to the GRE data and used as a regularization for the single-compartment quantitative BOLD fit to the GESSE and GRE data, respectively, to quantify OEF, deoxygenated blood volume (ν), R2, and non-blood susceptibility (χnb). Intersubject means within gray and white matter, respectively, were compared between GESSE and GRE (Student's t) and gray-white matter contrast was determined for each sequence separately. A single- and multi-compartment simulation was used to compare reconstruction accuracy. Results Intersubject means and SDs for gray and white matter were OEF = 32.4 ± 1.6%, ν = 2.9 ± 0.1%, R2 = 14.2 ± 0.5 Hz, χnb = −43 ± 5 ppb for GESSE and OEF = 43.0 ± 5.4%, ν = 3.5 ± 0.4%, R2 = 14.4 ± 0.7 Hz, χnb = −43 ± 8 ppb for GRE with a significant difference (P < 0.05) for OEF and ν. Gray-white matter contrast was significant (P < 0.05) in all parameters for GESSE but only in ν and R2 for GRE. All parameters reconstructed from GESSE had higher accuracy than from GRE in the single- but not multi-compartment simulation. Conclusion GESSE yields higher parameter accuracy in simulated gray matter but produces unphysiological gray-white matter contrast in OEF in vivo. GRE produces uniform OEF maps in vivo and is more efficient, which could facilitate a clinical implementation, but revealed biases in simulation. The appropriate sequence should be chosen depending on application. 
650 4 |a GESSE 
650 4 |a GRE 
650 4 |a oxygen extraction fraction 
650 4 |a quantitative BOLD 
650 4 |a quantitative susceptibility mapping 
700 1 |a Thomas, Sebastian  |d 1988-  |e VerfasserIn  |0 (DE-588)1199975931  |0 (DE-627)1682122204  |4 aut 
700 1 |a Cho, Junghun  |e VerfasserIn  |4 aut 
700 1 |a Zhang, Shun  |e VerfasserIn  |4 aut 
700 1 |a Wang, Yi  |e VerfasserIn  |4 aut 
700 1 |a Schad, Lothar R.  |d 1956-  |e VerfasserIn  |0 (DE-588)1028817630  |0 (DE-627)731640241  |0 (DE-576)376271221  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 82(2019), 4, Seite 1491-1503  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach 
773 1 8 |g volume:82  |g year:2019  |g number:4  |g pages:1491-1503  |g extent:13  |a Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach 
856 4 0 |u https://doi.org/10.1002/mrm.27804  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.27804  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20191119 
993 |a Article 
994 |a 2019 
998 |g 1028817630  |a Schad, Lothar R.  |m 1028817630:Schad, Lothar R.  |d 60000  |d 65200  |e 60000PS1028817630  |e 65200PS1028817630  |k 0/60000/  |k 1/60000/65200/  |p 6  |y j 
998 |g 1199975931  |a Thomas, Sebastian  |m 1199975931:Thomas, Sebastian  |d 60000  |d 65200  |e 60000PT1199975931  |e 65200PT1199975931  |k 0/60000/  |k 1/60000/65200/  |p 2 
998 |g 1199573892  |a Hubertus, Simon Ralph  |m 1199573892:Hubertus, Simon Ralph  |d 60000  |d 65200  |e 60000PH1199573892  |e 65200PH1199573892  |k 0/60000/  |k 1/60000/65200/  |p 1  |x j 
999 |a KXP-PPN1682125688  |e 3542360376 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"02 June 2019"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"relHost":[{"note":["Gesehen am 28.02.08"],"disp":"Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approachMagnetic resonance in medicine","id":{"zdb":["1493786-4"],"doi":["10.1002/(ISSN)1522-2594"],"eki":["303257040"],"issn":["1522-2594"]},"title":[{"subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Magnetic resonance in medicine","title":"Magnetic resonance in medicine"}],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"1984-","dateIssuedKey":"1984","publisherPlace":"New York, NY [u.a.]","publisher":"Wiley-Liss"}],"part":{"extent":"13","year":"2019","pages":"1491-1503","text":"82(2019), 4, Seite 1491-1503","volume":"82","issue":"4"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"303257040","pubHistory":["1.1984 -"],"titleAlt":[{"title":"MRM"}]}],"name":{"displayForm":["Simon Hubertus, Sebastian Thomas, Junghun Cho, Shun Zhang, Yi Wang, Lothar Rudi Schad"]},"person":[{"given":"Simon Ralph","role":"aut","display":"Hubertus, Simon Ralph","family":"Hubertus","roleDisplay":"VerfasserIn"},{"family":"Thomas","roleDisplay":"VerfasserIn","given":"Sebastian","role":"aut","display":"Thomas, Sebastian"},{"roleDisplay":"VerfasserIn","family":"Cho","display":"Cho, Junghun","role":"aut","given":"Junghun"},{"roleDisplay":"VerfasserIn","family":"Zhang","role":"aut","display":"Zhang, Shun","given":"Shun"},{"given":"Yi","display":"Wang, Yi","role":"aut","roleDisplay":"VerfasserIn","family":"Wang"},{"given":"Lothar R.","role":"aut","display":"Schad, Lothar R.","family":"Schad","roleDisplay":"VerfasserIn"}],"physDesc":[{"extent":"13 S."}],"note":["Gesehen am 19.11.2019"],"recId":"1682125688","id":{"doi":["10.1002/mrm.27804"],"eki":["1682125688"]},"title":[{"title":"Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach","title_sort":"Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach"}]} 
SRT |a HUBERTUSSICOMPARISON0220