Self-supplied liquid injection field desorption/ionization ion source for an orthogonal time-of-flight instrument

A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Linden, Mathias H. (VerfasserIn) , Linden, H. Bernhard (VerfasserIn) , Nieth, Norbert (VerfasserIn) , Gross, Jürgen H. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2 August2019
In: Journal of the American Society for Mass Spectrometry
Year: 2019, Jahrgang: 30, Heft: 11, Pages: 2358-2368
ISSN:1879-1123
DOI:10.1007/s13361-019-02297-1
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s13361-019-02297-1
Volltext
Verfasserangaben:Mathias H. Linden, H. Bernhard Linden, Norbert Nieth, Jürgen H. Gross

MARC

LEADER 00000caa a2200000 c 4500
001 1682419045
003 DE-627
005 20230428044119.0
007 cr uuu---uuuuu
008 191121s2019 xx |||||o 00| ||eng c
024 7 |a 10.1007/s13361-019-02297-1  |2 doi 
035 |a (DE-627)1682419045 
035 |a (DE-599)KXP1682419045 
035 |a (OCoLC)1341278510 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 30  |2 sdnb 
100 1 |a Linden, Mathias H.  |e VerfasserIn  |0 (DE-588)1200162412  |0 (DE-627)1682418200  |4 aut 
245 1 0 |a Self-supplied liquid injection field desorption/ionization ion source for an orthogonal time-of-flight instrument  |c Mathias H. Linden, H. Bernhard Linden, Norbert Nieth, Jürgen H. Gross 
264 1 |c 2 August2019 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.11.2019 
520 |a A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this third-party LIFDI probe and source combination does not require the exchange of the entire ion source comprising ion source block and lens stack to switch from electron ionization (EI) to LIFDI. Rather, the methods may be swapped conveniently by only exchanging the ion source block for a mechanical probe guide and inserting the LIFDI probe in place of the standard direct insertion probe (DIP) via the vacuum lock. Further, this LIFDI setup does not require any changes of the electronics or software of the AccuTOF mass spectrometer because it is self-supplied in terms of power supply, observation optics, and computer control. The setup offers advanced FI/FD/LIFDI control features such as emission-controlled emitter heating current and emitter flash baking during elongated runs as required for gas chromatography-FI-mass spectrometry (MS). The LIFDI source and probe and its operation are reported in detail. FI spectra of the volatile analytes toluene, heptane, and pentafluoroiodobenzene are presented. LIFDI operation is demonstrated for the analysis of the saturated hydrocarbon dotriacontane and the low-mass hydrocarbon polymers polystyrene 484 and polystyrene 1050. Further, the air-sensitive 2nd-generation Hoveyda-Grubbs catalyst is analyzed by LIFDI-MS. For comparison with long-established LIFDI instrumentation, some of the spectra obtained with the new setup are also compared with those from a double-focusing magnetic sector instrument. Open image in new window 
650 4 |a Alkanes 
650 4 |a Field desorption (FD) 
650 4 |a Field ionization (FI) 
650 4 |a Hoveyda-Grubbs II catalyst 
650 4 |a Liquid injection field desorption ionization (LIFDI) 
650 4 |a Magnetic sector analyzer 
650 4 |a Orthogonal time-of-flight analyzer 
650 4 |a Polystyrene 
700 1 |a Linden, H. Bernhard  |e VerfasserIn  |0 (DE-588)1171542607  |0 (DE-627)1040630898  |0 (DE-576)513784713  |4 aut 
700 1 |a Nieth, Norbert  |e VerfasserIn  |0 (DE-588)1200163257  |0 (DE-627)1682418847  |4 aut 
700 1 |a Gross, Jürgen H.  |d 1963-  |e VerfasserIn  |0 (DE-588)1028129734  |0 (DE-627)730387143  |0 (DE-576)375656391  |4 aut 
773 0 8 |i Enthalten in  |a American Society for Mass Spectrometry  |t Journal of the American Society for Mass Spectrometry  |d Washington, DC : ACS Publications, 1990  |g 30(2019), 11, Seite 2358-2368  |h Online-Ressource  |w (DE-627)320598799  |w (DE-600)2019911-9  |w (DE-576)259485098  |x 1879-1123  |7 nnas 
773 1 8 |g volume:30  |g year:2019  |g number:11  |g pages:2358-2368  |g extent:11  |a Self-supplied liquid injection field desorption/ionization ion source for an orthogonal time-of-flight instrument 
856 4 0 |u https://doi.org/10.1007/s13361-019-02297-1  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20191121 
993 |a Article 
994 |a 2019 
998 |g 1028129734  |a Gross, Jürgen H.  |m 1028129734:Gross, Jürgen H.  |d 120000  |d 120100  |e 120000PG1028129734  |e 120100PG1028129734  |k 0/120000/  |k 1/120000/120100/  |p 4  |y j 
998 |g 1200163257  |a Nieth, Robert  |m 1200163257:Nieth, Robert  |d 120000  |d 120100  |e 120000PN1200163257  |e 120100PN1200163257  |k 0/120000/  |k 1/120000/120100/  |p 3 
999 |a KXP-PPN1682419045  |e 3544048817 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"11 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"1990-","dateIssuedKey":"1990","publisher":"ACS Publications ; Elsevier Science ; Springer","publisherPlace":"Washington, DC ; Amsterdam ; New York"}],"id":{"eki":["320598799"],"zdb":["2019911-9"],"issn":["1879-1123"]},"pubHistory":["1.1990 -"],"part":{"volume":"30","text":"30(2019), 11, Seite 2358-2368","extent":"11","year":"2019","issue":"11","pages":"2358-2368"},"titleAlt":[{"title":"Mass spectrometry"},{"title":"JASMS online"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"American Society for Mass SpectrometryJournal of the American Society for Mass Spectrometry","note":["Gesehen am 19.04.2023"],"recId":"320598799","language":["eng"],"corporate":[{"role":"aut","display":"American Society for Mass Spectrometry","roleDisplay":"VerfasserIn"}],"title":[{"title_sort":"Journal of the American Society for Mass Spectrometry","title":"Journal of the American Society for Mass Spectrometry","subtitle":"JASMS online"}]}],"name":{"displayForm":["Mathias H. Linden, H. Bernhard Linden, Norbert Nieth, Jürgen H. Gross"]},"origin":[{"dateIssuedDisp":"2 August2019","dateIssuedKey":"2019"}],"id":{"doi":["10.1007/s13361-019-02297-1"],"eki":["1682419045"]},"note":["Gesehen am 21.11.2019"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1682419045","person":[{"family":"Linden","given":"Mathias H.","display":"Linden, Mathias H.","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Linden, H. Bernhard","roleDisplay":"VerfasserIn","role":"aut","family":"Linden","given":"H. Bernhard"},{"family":"Nieth","given":"Norbert","roleDisplay":"VerfasserIn","display":"Nieth, Norbert","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Gross, Jürgen H.","role":"aut","family":"Gross","given":"Jürgen H."}],"title":[{"title_sort":"Self-supplied liquid injection field desorption/ionization ion source for an orthogonal time-of-flight instrument","title":"Self-supplied liquid injection field desorption/ionization ion source for an orthogonal time-of-flight instrument"}]} 
SRT |a LINDENMATHSELFSUPPLI2201