Software-defined radio readout system for the ECHo experiment
Metallic magnetic calorimeters (MMCs) are highly linear cryogenic detectors that offer an excellent energy resolution, a signal rise time of <;100 ns, and a high dynamic range. MMCs are of high interest for many experiments. One of them, i.e., the Electron Capture (EC) in 163Ho (ECHo) experiment,...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
July 2019
|
| In: |
IEEE transactions on nuclear science
Year: 2019, Jahrgang: 66, Heft: 7, Pages: 1204-1209 |
| ISSN: | 1558-1578 |
| Online-Zugang: |
|
| Verfasserangaben: | O. Sander, N. Karcher, O. Krömer, S. Kempf, M. Wegner, C. Enss, and M. Weber |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1683544676 | ||
| 003 | DE-627 | ||
| 005 | 20220817164526.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 191126s2019 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1109/TNS.2019.2914665 |2 doi | |
| 035 | |a (DE-627)1683544676 | ||
| 035 | |a (DE-599)KXP1683544676 | ||
| 035 | |a (OCoLC)1341278549 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Sander, Oliver |e VerfasserIn |0 (DE-588)1012081397 |0 (DE-627)704830353 |0 (DE-576)341326550 |4 aut | |
| 245 | 1 | 0 | |a Software-defined radio readout system for the ECHo experiment |c O. Sander, N. Karcher, O. Krömer, S. Kempf, M. Wegner, C. Enss, and M. Weber |
| 264 | 1 | |c July 2019 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 26.11.2019 | ||
| 520 | |a Metallic magnetic calorimeters (MMCs) are highly linear cryogenic detectors that offer an excellent energy resolution, a signal rise time of <;100 ns, and a high dynamic range. MMCs are of high interest for many experiments. One of them, i.e., the Electron Capture (EC) in 163Ho (ECHo) experiment, requires the utilization of large MMC detector arrays. The readout of such MMC arrays is a challenging task, which can be tackled using software-defined radios (SDRs). Although SDR is a well-known approach in communications engineering, a dedicated implementation for frequency division multiplexed readout of MMCs is new and one of the technological key elements of the ECHo project. ECHo will be the first experiment to use microwave superconducting quantum interference device (SQUID) multiplexed MMC detectors, and therefore, pioneering the hardware, firmware, and software development in this domain. This paper presents the detailed concepts and current status of the development. | ||
| 650 | 4 | |a calorimeters | |
| 650 | 4 | |a communications engineering | |
| 650 | 4 | |a Detectors | |
| 650 | 4 | |a ECHo experiment | |
| 650 | 4 | |a ECHo project | |
| 650 | 4 | |a electron capture | |
| 650 | 4 | |a Electron Capture (EC) in ¹⁶³Ho (ECHo) | |
| 650 | 4 | |a excellent energy resolution | |
| 650 | 4 | |a field-programmable gate array (FPGA) | |
| 650 | 4 | |a frequency division multiplexed readout | |
| 650 | 4 | |a Frequency division multiplexing | |
| 650 | 4 | |a high dynamic range | |
| 650 | 4 | |a highly linear cryogenic detectors | |
| 650 | 4 | |a Magnetometers | |
| 650 | 4 | |a metallic magnetic calorimeters | |
| 650 | 4 | |a micro calorimeters | |
| 650 | 4 | |a microwave superconducting quantum interference device (SQUID) multiplex | |
| 650 | 4 | |a microwave superconducting quantum interference device multiplexed MMC detectors | |
| 650 | 4 | |a MMC arrays | |
| 650 | 4 | |a MMC detector arrays | |
| 650 | 4 | |a readout electronics | |
| 650 | 4 | |a Resonant frequency | |
| 650 | 4 | |a RF systems | |
| 650 | 4 | |a signal rise time | |
| 650 | 4 | |a software development | |
| 650 | 4 | |a software radio | |
| 650 | 4 | |a software-defined radio (SDR) | |
| 650 | 4 | |a software-defined radio readout system | |
| 650 | 4 | |a software-defined radios | |
| 650 | 4 | |a SQUIDs | |
| 650 | 4 | |a Superconducting magnets | |
| 650 | 4 | |a technological key elements | |
| 700 | 1 | |a Karcher, Nick |e VerfasserIn |0 (DE-588)1262527945 |0 (DE-627)1810230624 |4 aut | |
| 700 | 1 | |a Krömer, O. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kempf, Sebastian |d 1983- |e VerfasserIn |0 (DE-588)1020440449 |0 (DE-627)69122143X |0 (DE-576)360448690 |4 aut | |
| 700 | 1 | |a Wegner, Mathias |d 1986- |e VerfasserIn |0 (DE-588)1176685597 |0 (DE-627)1047656418 |0 (DE-576)516756893 |4 aut | |
| 700 | 1 | |a Enss, Christian |d 1960- |e VerfasserIn |0 (DE-588)1020467878 |0 (DE-627)691227020 |0 (DE-576)360449530 |4 aut | |
| 700 | 1 | |a Weber, Marc |e VerfasserIn |0 (DE-588)1036677060 |0 (DE-627)750757175 |0 (DE-576)385241585 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |a Institute of Electrical and Electronics Engineers |t IEEE transactions on nuclear science |d New York, NY : IEEE, 1963 |g 66(2019), 7, Seite 1204-1209 |h Online-Ressource |w (DE-627)320645835 |w (DE-600)2025398-9 |w (DE-576)094110956 |x 1558-1578 |7 nnas |
| 773 | 1 | 8 | |g volume:66 |g year:2019 |g number:7 |g pages:1204-1209 |g extent:6 |a Software-defined radio readout system for the ECHo experiment |
| 951 | |a AR | ||
| 992 | |a 20191126 | ||
| 993 | |a Article | ||
| 994 | |a 2019 | ||
| 998 | |g 1020467878 |a Enss, Christian |m 1020467878:Enss, Christian |d 130000 |d 130700 |e 130000PE1020467878 |e 130700PE1020467878 |k 0/130000/ |k 1/130000/130700/ |p 6 | ||
| 998 | |g 1176685597 |a Wegner, Mathias |m 1176685597:Wegner, Mathias |d 130000 |d 130700 |e 130000PW1176685597 |e 130700PW1176685597 |k 0/130000/ |k 1/130000/130700/ |p 5 | ||
| 998 | |g 1020440449 |a Kempf, Sebastian |m 1020440449:Kempf, Sebastian |d 130000 |d 130700 |e 130000PK1020440449 |e 130700PK1020440449 |k 0/130000/ |k 1/130000/130700/ |p 4 | ||
| 999 | |a KXP-PPN1683544676 |e 3550131739 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["O. Sander, N. Karcher, O. Krömer, S. Kempf, M. Wegner, C. Enss, and M. Weber"]},"recId":"1683544676","note":["Gesehen am 26.11.2019"],"title":[{"title":"Software-defined radio readout system for the ECHo experiment","title_sort":"Software-defined radio readout system for the ECHo experiment"}],"person":[{"role":"aut","given":"Oliver","display":"Sander, Oliver","family":"Sander"},{"role":"aut","given":"Nick","display":"Karcher, Nick","family":"Karcher"},{"role":"aut","given":"O.","family":"Krömer","display":"Krömer, O."},{"given":"Sebastian","display":"Kempf, Sebastian","family":"Kempf","role":"aut"},{"role":"aut","display":"Wegner, Mathias","family":"Wegner","given":"Mathias"},{"role":"aut","given":"Christian","display":"Enss, Christian","family":"Enss"},{"role":"aut","display":"Weber, Marc","family":"Weber","given":"Marc"}],"physDesc":[{"extent":"6 S."}],"relHost":[{"id":{"eki":["320645835"],"issn":["1558-1578"],"zdb":["2025398-9"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"corporate":[{"display":"Institute of Electrical and Electronics Engineers","role":"aut"}],"part":{"issue":"7","extent":"6","year":"2019","text":"66(2019), 7, Seite 1204-1209","pages":"1204-1209","volume":"66"},"physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"Transactions on nuclear science"}],"title":[{"subtitle":"a publication of the IEEE Nuclear and Plasma Sciences Society","title":"IEEE transactions on nuclear science","title_sort":"IEEE transactions on nuclear science"}],"origin":[{"publisherPlace":"New York, NY","dateIssuedDisp":"1963-","dateIssuedKey":"1963","publisher":"IEEE"}],"note":["Gesehen am 12.12.07"],"pubHistory":["10.1963 -"],"recId":"320645835","disp":"Institute of Electrical and Electronics EngineersIEEE transactions on nuclear science"}],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"July 2019"}],"language":["eng"],"id":{"doi":["10.1109/TNS.2019.2914665"],"eki":["1683544676"]},"type":{"media":"Online-Ressource","bibl":"article-journal"}} | ||
| SRT | |a SANDEROLIVSOFTWAREDE2019 | ||