Novel neutron detectors based on the time projection method
We present the first prototype of a novel thermal neutron detector using the time projection method. The system consists of 8 TimePix ASICs with postprocessed InGrid meshes. Each ASIC has 256×256 pixels of 55µm×55µm in size with the capability to measure charge or time. This allows to visualize enti...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
15 March 2018
|
| In: |
Physica. B, Condensed matter
Year: 2018, Volume: 551, Pages: 517-522 |
| ISSN: | 1873-2135 |
| DOI: | 10.1016/j.physb.2018.03.026 |
| Online Access: | Resolving-System, Volltext: https://doi.org/10.1016/j.physb.2018.03.026 Verlag: http://www.sciencedirect.com/science/article/pii/S0921452618302187 |
| Author Notes: | M. Köhli, K. Desch, M. Gruber, J. Kaminski, F.P. Schmidt, T. Wagner |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1683644425 | ||
| 003 | DE-627 | ||
| 005 | 20220817164816.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 191127s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.physb.2018.03.026 |2 doi | |
| 035 | |a (DE-627)1683644425 | ||
| 035 | |a (DE-599)KXP1683644425 | ||
| 035 | |a (OCoLC)1341278902 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Köhli, Markus |d 1984- |e VerfasserIn |0 (DE-588)1155859200 |0 (DE-627)1018340483 |0 (DE-576)501908013 |4 aut | |
| 245 | 1 | 0 | |a Novel neutron detectors based on the time projection method |c M. Köhli, K. Desch, M. Gruber, J. Kaminski, F.P. Schmidt, T. Wagner |
| 264 | 1 | |c 15 March 2018 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 27.11.2019 | ||
| 520 | |a We present the first prototype of a novel thermal neutron detector using the time projection method. The system consists of 8 TimePix ASICs with postprocessed InGrid meshes. Each ASIC has 256×256 pixels of 55µm×55µm in size with the capability to measure charge or time. This allows to visualize entire conversion particle tracks with their spatial and time information and, by using event reconstruction algorithms, discriminate against the background of others. By using the Scalable Readout System the detector as presented here could also be upscaled to much larger active areas. In the current configuration with a B410C layer of 1μm thickness aligned in parallel to the readout we could achieve in Ar:CO2 80:20 a spatial resolution of σ=(115±8)μm. | ||
| 650 | 4 | |a Boron | |
| 650 | 4 | |a Neutron converter | |
| 650 | 4 | |a Neutron detection | |
| 650 | 4 | |a Position sensitive | |
| 650 | 4 | |a Time projection chamber | |
| 650 | 4 | |a TimePix | |
| 773 | 0 | 8 | |i Enthalten in |t Physica. B, Condensed matter |d Amsterdam : Elsevier, 1988 |g 551(2018), Seite 517-522 |h Online-Ressource |w (DE-627)266015093 |w (DE-600)1466579-7 |w (DE-576)074959840 |x 1873-2135 |7 nnas |a Novel neutron detectors based on the time projection method |
| 773 | 1 | 8 | |g volume:551 |g year:2018 |g pages:517-522 |g extent:6 |a Novel neutron detectors based on the time projection method |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.physb.2018.03.026 |x Resolving-System |x Verlag |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0921452618302187 |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20191127 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 1155859200 |a Köhli, Markus |m 1155859200:Köhli, Markus |d 130000 |d 130200 |e 130000PK1155859200 |e 130200PK1155859200 |k 0/130000/ |k 1/130000/130200/ |p 1 |x j | ||
| 999 | |a KXP-PPN1683644425 |e 3550539525 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"family":"Köhli","display":"Köhli, Markus","role":"aut","given":"Markus"}],"language":["eng"],"title":[{"title":"Novel neutron detectors based on the time projection method","title_sort":"Novel neutron detectors based on the time projection method"}],"note":["Gesehen am 27.11.2019"],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"15 March 2018"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"6 S."}],"name":{"displayForm":["M. Köhli, K. Desch, M. Gruber, J. Kaminski, F.P. Schmidt, T. Wagner"]},"relHost":[{"titleAlt":[{"title":"Physica / B"}],"part":{"year":"2018","pages":"517-522","volume":"551","extent":"6","text":"551(2018), Seite 517-522"},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Novel neutron detectors based on the time projection methodPhysica. B, Condensed matter","pubHistory":["152.1988 - 407.2012; Vol. 408.2013 -"],"origin":[{"dateIssuedKey":"1988","publisher":"Elsevier ; North-Holland Physics Publ.","dateIssuedDisp":"1988-","publisherPlace":"Amsterdam ; Amsterdam"}],"note":["Gesehen am 06.06.23"],"title":[{"title":"Physica","partname":"Condensed matter","title_sort":"Physica"}],"id":{"zdb":["1466579-7"],"issn":["1873-2135"],"eki":["266015093"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"266015093"}],"recId":"1683644425","id":{"doi":["10.1016/j.physb.2018.03.026"],"eki":["1683644425"]}} | ||
| SRT | |a KOEHLIMARKNOVELNEUTR1520 | ||