Voxel-size dependent quantitative susceptibility mapping of blood vessel networks: a simulation study
Quantitative susceptibility mapping provides a measure for the local susceptibility within a voxel in magnetic resonance imaging (MRI). So far, theoretical and numerical studies focus on the assumption of a constant susceptibility inside each MR voxel. For blood vessel networks, however, susceptibil...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2019
|
| In: |
Zeitschrift für medizinische Physik
Year: 2018, Jahrgang: 29, Heft: 3, Pages: 282-291 |
| ISSN: | 1876-4436 |
| DOI: | 10.1016/j.zemedi.2018.09.002 |
| Online-Zugang: | Verlag, Volltext: https://doi.org/10.1016/j.zemedi.2018.09.002 Verlag: http://www.sciencedirect.com/science/article/pii/S0939388918300758 |
| Verfasserangaben: | Lukas R. Buschle, Thomas Kampf, Felix T. Kurz, Volker J.F. Sturm, Mirko Pham, Heinz-Peter Schlemmer, Christian H. Ziener |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1683815327 | ||
| 003 | DE-627 | ||
| 005 | 20230426071223.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 191129r20192018xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.zemedi.2018.09.002 |2 doi | |
| 035 | |a (DE-627)1683815327 | ||
| 035 | |a (DE-599)KXP1683815327 | ||
| 035 | |a (OCoLC)1341279173 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Buschle, Lukas R. |e VerfasserIn |0 (DE-588)1138362573 |0 (DE-627)895871963 |0 (DE-576)492500517 |4 aut | |
| 245 | 1 | 0 | |a Voxel-size dependent quantitative susceptibility mapping of blood vessel networks |b a simulation study |c Lukas R. Buschle, Thomas Kampf, Felix T. Kurz, Volker J.F. Sturm, Mirko Pham, Heinz-Peter Schlemmer, Christian H. Ziener |
| 264 | 1 | |c 2019 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 11 October 2018 | ||
| 500 | |a Gesehen am 29.11.2019 | ||
| 520 | |a Quantitative susceptibility mapping provides a measure for the local susceptibility within a voxel in magnetic resonance imaging (MRI). So far, theoretical and numerical studies focus on the assumption of a constant susceptibility inside each MR voxel. For blood vessel networks, however, susceptibility differences between blood and surrounding tissue occur on a much smaller length scale than the typical voxel size in routine MRI. In this work, the dependency of the quantitative susceptibility value on vessel size and voxel size is analyzed. | ||
| 534 | |c 2018 | ||
| 650 | 4 | |a Blood vessel networks | |
| 650 | 4 | |a Functional quantitative susceptibility mapping | |
| 650 | 4 | |a MR microstructure | |
| 650 | 4 | |a Phase images | |
| 700 | 1 | |a Kurz, Felix T. |d 1981- |e VerfasserIn |0 (DE-588)1043285474 |0 (DE-627)771321066 |0 (DE-576)394610342 |4 aut | |
| 700 | 1 | |a Sturm, Volker Jörg Friedrich |d 1980- |e VerfasserIn |0 (DE-588)1096228149 |0 (DE-627)856637238 |0 (DE-576)467929971 |4 aut | |
| 700 | 1 | |a Schlemmer, Heinz-Peter |d 1961- |e VerfasserIn |0 (DE-588)1025559967 |0 (DE-627)722927142 |0 (DE-576)17334805X |4 aut | |
| 700 | 1 | |a Ziener, Christian H. |d 1978- |e VerfasserIn |0 (DE-588)137982755 |0 (DE-627)59885309X |0 (DE-576)306117355 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Zeitschrift für medizinische Physik |d Amsterdam [u.a.] : Elsevier, 1990 |g 29(2019), 3, Seite 282-291 |w (DE-627)510617662 |w (DE-600)2231492-1 |w (DE-576)272350818 |x 1876-4436 |7 nnas |a Voxel-size dependent quantitative susceptibility mapping of blood vessel networks a simulation study |
| 773 | 1 | 8 | |g volume:29 |g year:2019 |g number:3 |g pages:282-291 |g extent:10 |a Voxel-size dependent quantitative susceptibility mapping of blood vessel networks a simulation study |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.zemedi.2018.09.002 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0939388918300758 |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20191129 | ||
| 993 | |a Article | ||
| 994 | |a 2019 | ||
| 998 | |g 137982755 |a Ziener, Christian H. |m 137982755:Ziener, Christian H. |d 50000 |e 50000PZ137982755 |k 0/50000/ |p 7 |y j | ||
| 998 | |g 1025559967 |a Schlemmer, Heinz-Peter |m 1025559967:Schlemmer, Heinz-Peter |d 50000 |e 50000PS1025559967 |k 0/50000/ |p 6 | ||
| 998 | |g 1096228149 |a Sturm, Volker Jörg Friedrich |m 1096228149:Sturm, Volker Jörg Friedrich |d 910000 |d 911100 |e 910000PS1096228149 |e 911100PS1096228149 |k 0/910000/ |k 1/910000/911100/ |p 4 | ||
| 998 | |g 1043285474 |a Kurz, Felix T. |m 1043285474:Kurz, Felix T. |d 910000 |d 911100 |e 910000PK1043285474 |e 911100PK1043285474 |k 0/910000/ |k 1/910000/911100/ |p 3 | ||
| 998 | |g 1138362573 |a Buschle, Lukas R. |m 1138362573:Buschle, Lukas R. |d 50000 |e 50000PB1138362573 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1683815327 |e 3551392668 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"person":[{"display":"Buschle, Lukas R.","family":"Buschle","role":"aut","given":"Lukas R."},{"display":"Kurz, Felix T.","family":"Kurz","role":"aut","given":"Felix T."},{"family":"Sturm","display":"Sturm, Volker Jörg Friedrich","role":"aut","given":"Volker Jörg Friedrich"},{"family":"Schlemmer","display":"Schlemmer, Heinz-Peter","given":"Heinz-Peter","role":"aut"},{"given":"Christian H.","role":"aut","display":"Ziener, Christian H.","family":"Ziener"}],"recId":"1683815327","relHost":[{"part":{"issue":"3","text":"29(2019), 3, Seite 282-291","year":"2019","pages":"282-291","extent":"10","volume":"29"},"titleAlt":[{"title":"Medizinische Physik"}],"language":["ger"],"corporate":[{"display":"Deutsche Gesellschaft für Medizinische Physik","role":"isb"},{"role":"isb","display":"Österreichische Gesellschaft für Medizinische Physik"}],"id":{"eki":["510617662"],"issn":["1876-4436"],"zdb":["2231492-1"]},"recId":"510617662","disp":"Voxel-size dependent quantitative susceptibility mapping of blood vessel networks a simulation studyZeitschrift für medizinische Physik","type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Volume 1, supplement (1990) ; volume 1, issue 1 (1991)-"],"origin":[{"dateIssuedDisp":"1990-","dateIssuedKey":"1990","publisher":"Elsevier","publisherPlace":"Amsterdam [u.a.]"}],"note":["Gesehen am 31.01.2022"],"title":[{"subtitle":"offizielles Organ der Deutschen, Österreichischen und Schweizerischen Gesellschaft für Medizinische Physik","title_sort":"Zeitschrift für medizinische Physik","title":"Zeitschrift für medizinische Physik"}]}],"name":{"displayForm":["Lukas R. Buschle, Thomas Kampf, Felix T. Kurz, Volker J.F. Sturm, Mirko Pham, Heinz-Peter Schlemmer, Christian H. Ziener"]},"physDesc":[{"extent":"10 S."}],"id":{"eki":["1683815327"],"doi":["10.1016/j.zemedi.2018.09.002"]},"note":["Available online 11 October 2018","Gesehen am 29.11.2019"],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"2019"}],"title":[{"title":"Voxel-size dependent quantitative susceptibility mapping of blood vessel networks","title_sort":"Voxel-size dependent quantitative susceptibility mapping of blood vessel networks","subtitle":"a simulation study"}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} | ||
| SRT | |a BUSCHLELUKVOXELSIZED2019 | ||