Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions

Purpose Hadron therapy has the capability to provide a high dose conformation to tumor regions. However, it requires an accurate target positioning. Thus, the precise monitoring of the patient's anatomical positioning during treatment is desirable. For this purpose, hadron-beam radiography with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gehrke, Tim (VerfasserIn) , Jäkel, Oliver (VerfasserIn) , Martišíková, Mária (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 6 January 2018
In: Medical physics
Year: 2018, Jahrgang: 45, Heft: 2, Pages: 817-829
ISSN:2473-4209
DOI:10.1002/mp.12723
Online-Zugang:Verlag, Volltext: https://doi.org/10.1002/mp.12723
Verlag: https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.12723
Volltext
Verfasserangaben:Tim Gehrke, Raya Gallas, Oliver Jäkel, Maria Martišíková

MARC

LEADER 00000caa a2200000 c 4500
001 1684848687
003 DE-627
005 20251106084711.0
007 cr uuu---uuuuu
008 191209s2018 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.12723  |2 doi 
035 |a (DE-627)1684848687 
035 |a (DE-599)KXP1684848687 
035 |a (OCoLC)1341280674 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Gehrke, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1044696982  |0 (DE-627)772571627  |0 (DE-576)398073740  |4 aut 
245 1 0 |a Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions  |c Tim Gehrke, Raya Gallas, Oliver Jäkel, Maria Martišíková 
264 1 |c 6 January 2018 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.12.2019 
520 |a Purpose Hadron therapy has the capability to provide a high dose conformation to tumor regions. However, it requires an accurate target positioning. Thus, the precise monitoring of the patient's anatomical positioning during treatment is desirable. For this purpose, hadron-beam radiography with protons (pRad) and ions (iRad) could be an attractive tool complementing the conventional imaging technologies. On the pathway to an envisaged clinical application, several challenges have to be addressed. Among them are achieving the desired spatial resolution in the presence of multiple Coulomb scattering (MCS), performing radiographs with a sufficient thickness resolution at clinically applicable dose levels, and the search for combinations of particularly suitable hadrons and detectors. These topics are investigated in this work for a detection system based on silicon pixel detectors. Methods A method of iRad based on energy deposition measurements in thin layers is introduced. It exploits a detection system consisting of three parallel silicon pixel detectors, which also enables particle tracking and identification. Helium ions, which exhibit less pronounced MCS than protons, were chosen as imaging radiation. A PMMA phantom with a mean water-equivalent thickness (WET) of 192 mm, containing maximal WET-variations of ±6 mm, was imaged with a 173 MeV/u helium ion beam at the Heidelberg Ion-Beam Therapy Center. WET-differences in form of 2.3 mm × 2.3 mm steps were aimed to be visualized and resolved in images of the energy deposition measured behind the phantom. The detection system was placed downstream of the imaged object in order to detect single ions leaving it. The combination of the measured information on energy deposition, ion type, and the track behind the phantom was used for the image formation, employing a self-developed data-processing procedure. Results It was shown that helium-beam radiography is feasible with the reported detection system. The introduced data preprocessing purified the detector signal from detector artifacts and improved the image quality. Additionally, the rejection of hydrogen ions originating from nuclear interactions was shown to increase the contrast-to-noise ratio (CNR) by at least a factor of 2.5. This enabled the resolution of relative thickness differences of 1.2% at a dose level typical for diagnostic x-ray images. The spatial resolution was improved by taking into account the direction of single helium ions leaving the phantom. A spatial resolution (MTF10%) of at least 1.15p mm−1 for the presented experimental set-up was achieved. Conclusion A successful feasibility study of helium-beam radiography with the introduced detection system was conducted. The methodology of iRad was based on energy deposition measurements in thin silicon layers. The tracking of single ions and the method of the ion identification was shown to be important for helium-beam radiography in terms of spatial resolution and CNR. 
650 4 |a helium-beam radiography 
650 4 |a ion imaging 
650 4 |a particle therapy 
650 4 |a secondary particles 
650 4 |a silicon pixel detectors 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Martišíková, Mária  |d 1979-  |e VerfasserIn  |0 (DE-588)1076839649  |0 (DE-627)835386767  |0 (DE-576)252899369  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 45(2018), 2, Seite 817-829  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions 
773 1 8 |g volume:45  |g year:2018  |g number:2  |g pages:817-829  |g extent:13  |a Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions 
856 4 0 |u https://doi.org/10.1002/mp.12723  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.12723  |x Verlag 
951 |a AR 
992 |a 20191209 
993 |a Article 
994 |a 2018 
998 |g 1076839649  |a Martišíková, Mária  |m 1076839649:Martišíková, Mária  |d 50000  |e 50000PM1076839649  |k 0/50000/  |p 4  |y j 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 3 
998 |g 1044696982  |a Gehrke, Tim  |m 1044696982:Gehrke, Tim  |d 50000  |e 50000PG1044696982  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1684848687  |e 3562108435 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"id":{"eki":["265784867"],"issn":["2473-4209","1522-8541"],"zdb":["1466421-5"]},"part":{"year":"2018","volume":"45","pages":"817-829","extent":"13","text":"45(2018), 2, Seite 817-829","issue":"2"},"name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]},"pubHistory":["1.1974 -"],"titleAlt":[{"title":"Medical physics online"}],"disp":"Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ionsMedical physics","recId":"265784867","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Medical physics","title_sort":"Medical physics"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 01.08.2025"],"origin":[{"dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}]}],"person":[{"display":"Gehrke, Tim","given":"Tim","role":"aut","family":"Gehrke"},{"given":"Oliver","role":"aut","family":"Jäkel","display":"Jäkel, Oliver"},{"display":"Martišíková, Mária","given":"Mária","role":"aut","family":"Martišíková"}],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"6 January 2018"}],"note":["Gesehen am 09.12.2019"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"title":"Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions","title_sort":"Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions"}],"physDesc":[{"extent":"13 S."}],"recId":"1684848687","name":{"displayForm":["Tim Gehrke, Raya Gallas, Oliver Jäkel, Maria Martišíková"]},"id":{"doi":["10.1002/mp.12723"],"eki":["1684848687"]}} 
SRT |a GEHRKETIMJPROOFOFPRI6201