Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma

ObjectivesThe aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC)....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Beer, Lucian (VerfasserIn) , Toepker, Michael (VerfasserIn) , Ba-Ssalamah, Ahmed (VerfasserIn) , Schestak, Christian (VerfasserIn) , Dutschke, Anja (VerfasserIn) , Schindl, Martin (VerfasserIn) , Wressnegger, Alexander (VerfasserIn) , Ringl, Helmut (VerfasserIn) , Apfaltrer, Paul (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 19 March 2019
In: European radiology
Year: 2019, Jahrgang: 29, Heft: 7, Pages: 3617-3625
ISSN:1432-1084
DOI:10.1007/s00330-019-06116-9
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s00330-019-06116-9
Volltext
Verfasserangaben:Lucian Beer, Michael Toepker, Ahmed Ba-Ssalamah, Christian Schestak, Anja Dutschke, Martin Schindl, Alexander Wressnegger, Helmut Ringl, Paul Apfaltrer

MARC

LEADER 00000caa a2200000 c 4500
001 1684875226
003 DE-627
005 20241221032645.0
007 cr uuu---uuuuu
008 191209s2019 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-019-06116-9  |2 doi 
035 |a (DE-627)1684875226 
035 |a (DE-599)KXP1684875226 
035 |a (OCoLC)1341280396 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Beer, Lucian  |d 1989-  |e VerfasserIn  |0 (DE-588)120132713X  |0 (DE-627)1684874653  |4 aut 
245 1 0 |a Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma  |c Lucian Beer, Michael Toepker, Ahmed Ba-Ssalamah, Christian Schestak, Anja Dutschke, Martin Schindl, Alexander Wressnegger, Helmut Ringl, Paul Apfaltrer 
264 1 |c 19 March 2019 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.12.2019 
520 |a ObjectivesThe aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC).MethodsThis retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient.ResultsLine-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement.ConclusionMEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC.Key Points • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC. 
650 4 |a Multidetector computed tomography 
650 4 |a Pancreatic neoplasms 
650 4 |a Signal-to-noise ratio 
700 1 |a Toepker, Michael  |e VerfasserIn  |4 aut 
700 1 |8 1\p  |a Ba-Ssalamah, Ahmed  |d 1962-  |e VerfasserIn  |0 (DE-588)140139702  |0 (DE-627)703579827  |0 (DE-576)314751238  |4 aut 
700 1 |a Schestak, Christian  |e VerfasserIn  |4 aut 
700 1 |a Dutschke, Anja  |e VerfasserIn  |4 aut 
700 1 |8 2\p  |a Schindl, Martin  |d 1967-  |e VerfasserIn  |0 (DE-588)129062545X  |0 (DE-627)1846210828  |4 aut 
700 1 |a Wressnegger, Alexander  |e VerfasserIn  |4 aut 
700 1 |a Ringl, Helmut  |e VerfasserIn  |4 aut 
700 1 |a Apfaltrer, Paul  |d 1983-  |e VerfasserIn  |0 (DE-588)1025309898  |0 (DE-627)722024924  |0 (DE-576)370191757  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 29(2019), 7, Seite 3617-3625  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma 
773 1 8 |g volume:29  |g year:2019  |g number:7  |g pages:3617-3625  |g extent:9  |a Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma 
856 4 0 |u https://doi.org/10.1007/s00330-019-06116-9  |x Verlag  |x Resolving-System  |3 Volltext 
883 |8 1\p  |a cgwrk  |d 20241001  |q DE-101  |u https://d-nb.info/provenance/plan#cgwrk 
883 |8 2\p  |a cgwrk  |d 20241001  |q DE-101  |u https://d-nb.info/provenance/plan#cgwrk 
951 |a AR 
992 |a 20191209 
993 |a Article 
994 |a 2019 
998 |g 1025309898  |a Apfaltrer, Paul  |m 1025309898:Apfaltrer, Paul  |d 60000  |d 62900  |e 60000PA1025309898  |e 62900PA1025309898  |k 0/60000/  |k 1/60000/62900/  |p 9  |y j 
999 |a KXP-PPN1684875226  |e 3562169760 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Lucian Beer, Michael Toepker, Ahmed Ba-Ssalamah, Christian Schestak, Anja Dutschke, Martin Schindl, Alexander Wressnegger, Helmut Ringl, Paul Apfaltrer"]},"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"19 March 2019"}],"id":{"eki":["1684875226"],"doi":["10.1007/s00330-019-06116-9"]},"physDesc":[{"extent":"9 S."}],"relHost":[{"origin":[{"publisher":"Springer","dateIssuedKey":"1991","dateIssuedDisp":"1991-","publisherPlace":"Berlin ; Heidelberg"}],"id":{"eki":["268757526"],"zdb":["1472718-3"],"issn":["1432-1084","1613-3757"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"official organ of the European Association of Radiology","title":"European radiology","title_sort":"European radiology"}],"disp":"Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinomaEuropean radiology","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"language":["eng"],"corporate":[{"display":"European Association of Radiology","roleDisplay":"Herausgebendes Organ","role":"isb"}],"recId":"268757526","pubHistory":["1.1991 -"],"part":{"year":"2019","issue":"7","pages":"3617-3625","text":"29(2019), 7, Seite 3617-3625","volume":"29","extent":"9"},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}]}],"person":[{"display":"Beer, Lucian","roleDisplay":"VerfasserIn","role":"aut","family":"Beer","given":"Lucian"},{"display":"Toepker, Michael","roleDisplay":"VerfasserIn","role":"aut","family":"Toepker","given":"Michael"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Ba-Ssalamah, Ahmed","given":"Ahmed","family":"Ba-Ssalamah"},{"role":"aut","display":"Schestak, Christian","roleDisplay":"VerfasserIn","given":"Christian","family":"Schestak"},{"given":"Anja","family":"Dutschke","role":"aut","display":"Dutschke, Anja","roleDisplay":"VerfasserIn"},{"given":"Martin","family":"Schindl","role":"aut","roleDisplay":"VerfasserIn","display":"Schindl, Martin"},{"display":"Wressnegger, Alexander","roleDisplay":"VerfasserIn","role":"aut","family":"Wressnegger","given":"Alexander"},{"role":"aut","display":"Ringl, Helmut","roleDisplay":"VerfasserIn","given":"Helmut","family":"Ringl"},{"role":"aut","display":"Apfaltrer, Paul","roleDisplay":"VerfasserIn","given":"Paul","family":"Apfaltrer"}],"title":[{"title_sort":"Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma","title":"Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 09.12.2019"],"language":["eng"],"recId":"1684875226"} 
SRT |a BEERLUCIANOBJECTIVEA1920