Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices: experience of a single institution

Background: Ionizing radiation was shown to be able to influence the function of cardiac implantable electronic devices (CIED’s) leading to malfunctions with potentially severe consequences. Those effects presumably correlate with beam energy and neutron production. Thus, restraining has been procla...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Seidensaal, Katharina (VerfasserIn) , Harrabi, Semi B. (VerfasserIn) , Scholz, Eberhard P. (VerfasserIn) , Ellerbrock, Malte (VerfasserIn) , Haberer, Thomas (VerfasserIn) , Weykamp, Fabian (VerfasserIn) , Mattke, Matthias (VerfasserIn) , Welte, Stefan Ezechiel (VerfasserIn) , Herfarth, Klaus (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Uhl, Matthias (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 22 August 2019
In: Frontiers in oncology
Year: 2019, Jahrgang: 9
ISSN:2234-943X
DOI:10.3389/fonc.2019.00798
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.3389/fonc.2019.00798
Verlag, kostenfrei, Volltext: https://www.frontiersin.org/articles/10.3389/fonc.2019.00798/full
Volltext
Verfasserangaben:Katharina Seidensaal, Semi Ben Harrabi, Eberhard Scholz, Malte Ellerbrock, Thomas Haberer, Fabian Weykamp, Matthias Mattke, Stefan E. Welte, Klaus Herfarth, Jürgen Debus and Matthias Uhl

MARC

LEADER 00000caa a2200000 c 4500
001 1686087578
003 DE-627
005 20210819113118.0
007 cr uuu---uuuuu
008 191219s2019 xx |||||o 00| ||eng c
024 7 |a 10.3389/fonc.2019.00798  |2 doi 
035 |a (DE-627)1686087578 
035 |a (DE-599)KXP1686087578 
035 |a (OCoLC)1264282728 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Seidensaal, Katharina  |d 1987-  |e VerfasserIn  |0 (DE-588)1084643685  |0 (DE-627)848624483  |0 (DE-576)456394869  |4 aut 
245 1 0 |a Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices  |b experience of a single institution  |c Katharina Seidensaal, Semi Ben Harrabi, Eberhard Scholz, Malte Ellerbrock, Thomas Haberer, Fabian Weykamp, Matthias Mattke, Stefan E. Welte, Klaus Herfarth, Jürgen Debus and Matthias Uhl 
264 1 |c 22 August 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.12.2019 
520 |a Background: Ionizing radiation was shown to be able to influence the function of cardiac implantable electronic devices (CIED’s) leading to malfunctions with potentially severe consequences. Those effects presumably correlate with beam energy and neutron production. Thus, restraining has been proclaimedparticle facilities are commonly cautious to for the treatment of patientstreat patients with CIED’s with particles, but substantial evidence is lacking. Methods and Materials: In total 31 patients were investigated, who have been treated at the Heidelberg Ion-Beam Therapy Center (HIT) from September 2012 to February 2019 with protons and carbon ions in active-scanning technique. All CIED’s were checked after every single irradiation by the department of cardiology. The minimum distance between the CIED and the planning target volume (PTV), the 10% isodose and the single beam in Beam’s Eye View (BEV) was analyzed for 12 patients. Results: In total, 31 patients received 32 courses of radiotherapy (RT). Twenty-two received treatment with carbon ion beam and ten with proton beam. The cumulative number of fractions was 582, the cumulative number of documented controls after RT was 504 (87%). Three patients had an implantable cardioverter-defibrillator (ICD) and 28 patients had a pacemaker at the time of treatment. Seven patients had a heart rate of ≤30 /min. The majority of patients (69%) were treated for tumors of the head and neck. The median minimum distance between CIED and PTV, 10 % isodose and the single beam on BEV was 13.4 cm, 11.6 cm and 8.3 cm, respectively. There were no registered events associated with the treatment in this evaluation. Conclusion: Treatment of CIED-patients with protons and carbon ions applied with active raster scanning technique was safe without any incidents in our single center experience. Monitoring after almost every fraction provided systematic and extensive data. Further investigations are necessary in order to form reliable guidelines, which should consider different modes of beam application, as active scanning supposedly provides a greater level of safety from malfunctions for patients with CIED undergoing particle irradiation. 
650 4 |a Beam scanning 
650 4 |a Cardiac implantable electronic device 
650 4 |a CIED malfunction 
650 4 |a particle therapy 
650 4 |a Proton therapy 
700 1 |a Harrabi, Semi B.  |d 1986-  |e VerfasserIn  |0 (DE-588)1044730161  |0 (DE-627)772596034  |0 (DE-576)398081298  |4 aut 
700 1 |a Scholz, Eberhard P.  |d 1978-  |e VerfasserIn  |0 (DE-588)13163660X  |0 (DE-627)512033994  |0 (DE-576)298640589  |4 aut 
700 1 |a Ellerbrock, Malte  |e VerfasserIn  |0 (DE-588)1075019427  |0 (DE-627)832853151  |0 (DE-576)443202346  |4 aut 
700 1 |a Haberer, Thomas  |d 1960-  |e VerfasserIn  |0 (DE-588)123579198  |0 (DE-627)706353714  |0 (DE-576)214902188  |4 aut 
700 1 |a Weykamp, Fabian  |d 1987-  |e VerfasserIn  |0 (DE-588)1072433036  |0 (DE-627)827655096  |0 (DE-576)43385992X  |4 aut 
700 1 |a Mattke, Matthias  |d 1987-  |e VerfasserIn  |0 (DE-588)1065410921  |0 (DE-627)816098476  |0 (DE-576)425123065  |4 aut 
700 1 |a Welte, Stefan Ezechiel  |d 1979-  |e VerfasserIn  |0 (DE-588)103362599X  |0 (DE-627)742088715  |0 (DE-576)381245284  |4 aut 
700 1 |a Herfarth, Klaus  |e VerfasserIn  |0 (DE-588)1032757582  |0 (DE-627)739273116  |0 (DE-576)171352289  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Uhl, Matthias  |d 1979-  |e VerfasserIn  |0 (DE-588)133372561  |0 (DE-627)544031091  |0 (DE-576)299803147  |4 aut 
773 0 8 |i Enthalten in  |t Frontiers in oncology  |d Lausanne : Frontiers Media, 2011  |g 9(2019) Artikel-Nummer 798, 6 Seiten  |h Online-Ressource  |w (DE-627)684965518  |w (DE-600)2649216-7  |w (DE-576)35841184X  |x 2234-943X  |7 nnas  |a Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices experience of a single institution 
773 1 8 |g volume:9  |g year:2019  |a Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices experience of a single institution 
856 4 0 |u https://doi.org/10.3389/fonc.2019.00798  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.frontiersin.org/articles/10.3389/fonc.2019.00798/full  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20191219 
993 |a Article 
994 |a 2019 
998 |g 133372561  |a Uhl, Matthias  |m 133372561:Uhl, Matthias  |d 910000  |d 911400  |e 910000PU133372561  |e 911400PU133372561  |k 0/910000/  |k 1/910000/911400/  |p 11  |y j 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 10 
998 |g 1032757582  |a Herfarth, Klaus  |m 1032757582:Herfarth, Klaus  |d 910000  |d 911400  |e 910000PH1032757582  |e 911400PH1032757582  |k 0/910000/  |k 1/910000/911400/  |p 9 
998 |g 103362599X  |a Welte, Stefan Ezechiel  |m 103362599X:Welte, Stefan Ezechiel  |d 910000  |d 911400  |e 910000PW103362599X  |e 911400PW103362599X  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 1065410921  |a Mattke, Matthias  |m 1065410921:Mattke, Matthias  |d 910000  |d 911400  |e 910000PM1065410921  |e 911400PM1065410921  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1072433036  |a Weykamp, Fabian  |m 1072433036:Weykamp, Fabian  |d 910000  |d 911400  |e 910000PW1072433036  |e 911400PW1072433036  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 123579198  |a Haberer, Thomas  |m 123579198:Haberer, Thomas  |d 910000  |d 950000  |d 950400  |e 910000PH123579198  |e 950000PH123579198  |e 950400PH123579198  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 5 
998 |g 1075019427  |a Ellerbrock, Malte  |m 1075019427:Ellerbrock, Malte  |d 910000  |d 911400  |e 910000PE1075019427  |e 911400PE1075019427  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 13163660X  |a Scholz, Eberhard P.  |m 13163660X:Scholz, Eberhard P.  |d 910000  |d 910100  |e 910000PS13163660X  |e 910100PS13163660X  |k 0/910000/  |k 1/910000/910100/  |p 3 
998 |g 1044730161  |a Harrabi, Semi B.  |m 1044730161:Harrabi, Semi B.  |d 910000  |d 911400  |e 910000PH1044730161  |e 911400PH1044730161  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1084643685  |a Seidensaal, Katharina  |m 1084643685:Seidensaal, Katharina  |d 910000  |d 911400  |e 910000PS1084643685  |e 911400PS1084643685  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1686087578  |e 3567213741 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1686087578","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 19.12.2019"],"id":{"doi":["10.3389/fonc.2019.00798"],"eki":["1686087578"]},"title":[{"title":"Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices","title_sort":"Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices","subtitle":"experience of a single institution"}],"name":{"displayForm":["Katharina Seidensaal, Semi Ben Harrabi, Eberhard Scholz, Malte Ellerbrock, Thomas Haberer, Fabian Weykamp, Matthias Mattke, Stefan E. Welte, Klaus Herfarth, Jürgen Debus and Matthias Uhl"]},"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"22 August 2019"}],"relHost":[{"pubHistory":["2011 -"],"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisherPlace":"Lausanne","publisher":"Frontiers Media"}],"note":["Gesehen am 07.11.13"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Frontiers in oncology","title":"Frontiers in oncology"}],"part":{"volume":"9","text":"9(2019) Artikel-Nummer 798, 6 Seiten","year":"2019"},"id":{"eki":["684965518"],"issn":["2234-943X"],"zdb":["2649216-7"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"684965518","disp":"Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices experience of a single institutionFrontiers in oncology"}],"person":[{"family":"Seidensaal","given":"Katharina","role":"aut","display":"Seidensaal, Katharina"},{"display":"Harrabi, Semi B.","given":"Semi B.","role":"aut","family":"Harrabi"},{"family":"Scholz","role":"aut","given":"Eberhard P.","display":"Scholz, Eberhard P."},{"role":"aut","given":"Malte","family":"Ellerbrock","display":"Ellerbrock, Malte"},{"display":"Haberer, Thomas","role":"aut","given":"Thomas","family":"Haberer"},{"family":"Weykamp","given":"Fabian","role":"aut","display":"Weykamp, Fabian"},{"given":"Matthias","role":"aut","family":"Mattke","display":"Mattke, Matthias"},{"role":"aut","given":"Stefan Ezechiel","family":"Welte","display":"Welte, Stefan Ezechiel"},{"family":"Herfarth","given":"Klaus","role":"aut","display":"Herfarth, Klaus"},{"family":"Debus","role":"aut","given":"Jürgen","display":"Debus, Jürgen"},{"family":"Uhl","given":"Matthias","role":"aut","display":"Uhl, Matthias"}]} 
SRT |a SEIDENSAALACTIVESCAN2220