MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRI
BACKGROUND AND PURPOSE: The incidence of metallic dental restorations and implants is increasing, and head and neck MR imaging is becoming challenging regarding artifacts. Our aim was to evaluate whether multiple-slab acquisition with view angle tilting gradient based on a sampling perfection with a...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
March 30, 2018
|
| In: |
American journal of neuroradiology
Year: 2018, Volume: 39, Issue: 7, Pages: 1322-1329 |
| ISSN: | 1936-959X |
| DOI: | 10.3174/ajnr.A5678 |
| Online Access: | Verlag, Volltext: https://doi.org/10.3174/ajnr.A5678 Verlag, Volltext: http://www.ajnr.org/content/39/7/1322 |
| Author Notes: | T. Hilgenfeld, M. Prager, F.S. Schwindling, M. Nittka, P. Rammelsberg, M. Bendszus, S. Heiland, and A. Juerchott |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1687318816 | ||
| 003 | DE-627 | ||
| 005 | 20220817204322.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200114s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3174/ajnr.A5678 |2 doi | |
| 035 | |a (DE-627)1687318816 | ||
| 035 | |a (DE-599)KXP1687318816 | ||
| 035 | |a (OCoLC)1341297975 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Hilgenfeld, Tim |d 1986- |e VerfasserIn |0 (DE-588)1106261917 |0 (DE-627)862954398 |0 (DE-576)473950316 |4 aut | |
| 245 | 1 | 0 | |a MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRI |c T. Hilgenfeld, M. Prager, F.S. Schwindling, M. Nittka, P. Rammelsberg, M. Bendszus, S. Heiland, and A. Juerchott |
| 264 | 1 | |c March 30, 2018 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Accepted after revision March 30, 2018 | ||
| 500 | |a Gesehen am 14.01.2020 | ||
| 520 | |a BACKGROUND AND PURPOSE: The incidence of metallic dental restorations and implants is increasing, and head and neck MR imaging is becoming challenging regarding artifacts. Our aim was to evaluate whether multiple-slab acquisition with view angle tilting gradient based on a sampling perfection with application-optimized contrasts by using different flip angle evolution (MSVAT-SPACE)-STIR and slice-encoding for metal artifact correction (SEMAC)-STIR are beneficial regarding artifact suppression compared with the SPACE-STIR and TSE-STIR in vitro and in vivo. - MATERIALS AND METHODS: At 3T, 3D artifacts of 2 dental implants, supporting different single crowns, were evaluated. Image quality was evaluated quantitatively (normalized signal-to-noise ratio) and qualitatively (2 reads by 2 blinded radiologists). Feasibility was tested in vivo in 5 volunteers and 5 patients, respectively. - RESULTS: Maximum achievable resolution and the normalized signal-to-noise ratio of MSVAT-SPACE-STIR were higher compared with SEMAC-STIR. Performance in terms of artifact correction was dependent on the material composition. For highly paramagnetic materials, SEMAC-STIR was superior to MSVAT-SPACE-STIR (27.8% smaller artifact volume) and TSE-STIR (93.2% less slice distortion). However, MSVAT-SPACE-STIR reduced the artifact size compared with SPACE-STIR by 71.5%. For low-paramagnetic materials, MSVAT-SPACE-STIR performed as well as SEMAC-STIR. Furthermore, MSVAT-SPACE-STIR decreased artifact volume by 69.5% compared with SPACE-STIR. The image quality of all sequences did not differ systematically. In vivo results were comparable with in vitro results. - CONCLUSIONS: Regarding susceptibility artifacts and acquisition time, MSVAT-SPACE-STIR might be advantageous over SPACE-STIR for high-resolution and isotropic head and neck imaging. Only for materials with high-susceptibility differences to soft tissue, the use of SEMAC-STIR might be beneficial. Within limited acquisition times, SEMAC-STIR cannot exploit its full advantage over TSE-STIR regarding artifact suppression. | ||
| 700 | 1 | |a Prager, Marcel |e VerfasserIn |0 (DE-588)1106261631 |0 (DE-627)86295357X |0 (DE-576)473950030 |4 aut | |
| 700 | 1 | |a Schwindling, Franz Sebastian |d 1986- |e VerfasserIn |0 (DE-588)1036843572 |0 (DE-627)751703613 |0 (DE-576)38697926X |4 aut | |
| 700 | 1 | |a Nittka, Mathias |d 1968- |e VerfasserIn |0 (DE-588)123361818 |0 (DE-627)706270991 |0 (DE-576)293675562 |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 700 | 1 | |a Bendszus, Martin |e VerfasserIn |0 (DE-588)1032676426 |0 (DE-627)738634131 |0 (DE-576)175567697 |4 aut | |
| 700 | 1 | |a Heiland, Sabine |e VerfasserIn |0 (DE-588)106732626X |0 (DE-627)818624450 |0 (DE-576)426561368 |4 aut | |
| 700 | 1 | |a Jürchott, Alexander |e VerfasserIn |0 (DE-588)1167429230 |0 (DE-627)1031103090 |0 (DE-576)511136137 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t American journal of neuroradiology |d Oak Brook, Ill. : Soc., 1980 |g 39(2018), 7, Seite 1322-1329 |h Online-Ressource |w (DE-627)320647331 |w (DE-600)2025541-X |w (DE-576)101556217 |x 1936-959X |7 nnas |a MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRI |
| 773 | 1 | 8 | |g volume:39 |g year:2018 |g number:7 |g pages:1322-1329 |g extent:8 |a MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRI |
| 856 | 4 | 0 | |u https://doi.org/10.3174/ajnr.A5678 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.ajnr.org/content/39/7/1322 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200114 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 1167429230 |a Jürchott, Alexander |m 1167429230:Jürchott, Alexander |d 910000 |d 911100 |e 910000PJ1167429230 |e 911100PJ1167429230 |k 0/910000/ |k 1/910000/911100/ |p 8 |y j | ||
| 998 | |g 106732626X |a Heiland, Sabine |m 106732626X:Heiland, Sabine |d 910000 |d 911100 |e 910000PH106732626X |e 911100PH106732626X |k 0/910000/ |k 1/910000/911100/ |p 7 | ||
| 998 | |g 1032676426 |a Bendszus, Martin |m 1032676426:Bendszus, Martin |d 910000 |d 911100 |e 910000PB1032676426 |e 911100PB1032676426 |k 0/910000/ |k 1/910000/911100/ |p 6 | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 5 | ||
| 998 | |g 1036843572 |a Schwindling, Franz Sebastian |m 1036843572:Schwindling, Franz Sebastian |d 910000 |d 910800 |e 910000PS1036843572 |e 910800PS1036843572 |k 0/910000/ |k 1/910000/910800/ |p 3 | ||
| 998 | |g 1106261631 |a Prager, Marcel |m 1106261631:Prager, Marcel |d 910000 |d 911100 |e 910000PP1106261631 |e 911100PP1106261631 |k 0/910000/ |k 1/910000/911100/ |p 2 | ||
| 998 | |g 1106261917 |a Hilgenfeld, Tim |m 1106261917:Hilgenfeld, Tim |d 910000 |d 911100 |e 910000PH1106261917 |e 911100PH1106261917 |k 0/910000/ |k 1/910000/911100/ |p 1 |x j | ||
| 999 | |a KXP-PPN1687318816 |e 3575123861 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["T. Hilgenfeld, M. Prager, F.S. Schwindling, M. Nittka, P. Rammelsberg, M. Bendszus, S. Heiland, and A. Juerchott"]},"id":{"doi":["10.3174/ajnr.A5678"],"eki":["1687318816"]},"origin":[{"dateIssuedDisp":"March 30, 2018","dateIssuedKey":"2018"}],"person":[{"display":"Hilgenfeld, Tim","given":"Tim","role":"aut","family":"Hilgenfeld"},{"display":"Prager, Marcel","family":"Prager","given":"Marcel","role":"aut"},{"display":"Schwindling, Franz Sebastian","role":"aut","given":"Franz Sebastian","family":"Schwindling"},{"display":"Nittka, Mathias","family":"Nittka","role":"aut","given":"Mathias"},{"display":"Rammelsberg, Peter","family":"Rammelsberg","given":"Peter","role":"aut"},{"given":"Martin","role":"aut","family":"Bendszus","display":"Bendszus, Martin"},{"given":"Sabine","role":"aut","family":"Heiland","display":"Heiland, Sabine"},{"display":"Jürchott, Alexander","given":"Alexander","role":"aut","family":"Jürchott"}],"relHost":[{"id":{"issn":["1936-959X"],"eki":["320647331"],"zdb":["2025541-X"]},"part":{"volume":"39","year":"2018","text":"39(2018), 7, Seite 1322-1329","extent":"8","issue":"7","pages":"1322-1329"},"name":{"displayForm":["American Society of Neuroradiology"]},"titleAlt":[{"title":"AJNR"}],"pubHistory":["1.1980 -"],"title":[{"subtitle":"AJNR","title":"American journal of neuroradiology","title_sort":"American journal of neuroradiology"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Gesehen am 31.01.25","Fortsetzung der Druck-Ausgabe"],"origin":[{"publisherPlace":"Oak Brook, Ill.","dateIssuedKey":"1980","dateIssuedDisp":"1980-","publisher":"Soc."}],"disp":"MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRIAmerican journal of neuroradiology","recId":"320647331","physDesc":[{"extent":"Online-Ressource"}]}],"title":[{"title_sort":"MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRI","title":"MSVAT-SPACE-STIR and SEMAC-STIR for reduction of metallic artifacts in 3T head and neck MRI"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Accepted after revision March 30, 2018","Gesehen am 14.01.2020"],"recId":"1687318816","physDesc":[{"extent":"8 S."}]} | ||
| SRT | |a HILGENFELDMSVATSPACE3020 | ||