The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty
Background - The twin peg femoral component was introduced for the cemented Oxford unicondylar knee to increase implant stability. The aim of this experimental study was to investigate the influence of the twin peg design on femoral interface temperature and maximum load to failure in comparison to...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
5 April 2018
|
| In: |
Clinical biomechanics
Year: 2018, Jahrgang: 55, Pages: 23-27 |
| ISSN: | 1879-1271 |
| DOI: | 10.1016/j.clinbiomech.2018.04.003 |
| Online-Zugang: | Verlag, Volltext: https://doi.org/10.1016/j.clinbiomech.2018.04.003 Verlag: http://www.sciencedirect.com/science/article/pii/S0268003318302900 |
| Verfasserangaben: | Tobias Reiner, Martin Schwarze, Benjamin Panzram, Matthias C. Klotz, Rudi G. Bitsch, Sebastian Jaeger |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1687586632 | ||
| 003 | DE-627 | ||
| 005 | 20220817205458.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200116s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.clinbiomech.2018.04.003 |2 doi | |
| 035 | |a (DE-627)1687586632 | ||
| 035 | |a (DE-599)KXP1687586632 | ||
| 035 | |a (OCoLC)1341298279 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Reiner, Tobias |d 1982- |e VerfasserIn |0 (DE-588)1038723787 |0 (DE-627)766370356 |0 (DE-576)392759853 |4 aut | |
| 245 | 1 | 4 | |a The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty |c Tobias Reiner, Martin Schwarze, Benjamin Panzram, Matthias C. Klotz, Rudi G. Bitsch, Sebastian Jaeger |
| 264 | 1 | |c 5 April 2018 | |
| 300 | |a 5 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 16.01.2020 | ||
| 520 | |a Background - The twin peg femoral component was introduced for the cemented Oxford unicondylar knee to increase implant stability. The aim of this experimental study was to investigate the influence of the twin peg design on femoral interface temperature and maximum load to failure in comparison to the single peg design. - Methods - In this experimental study medial Oxford unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen human knees. A cemented femoral single peg component was implanted on the one side (group A) and a cemented twin peg component on the other side (group B). Cement interface temperature was continuously monitored during the procedure. Maximum tensile forces of the femoral components were measured by pull-out tests. - Findings - Maximum femoral interface temperatures did not reach critical values for heat necrosis of the bone in group A (mean 28.4, SD 1.2°C) or group B (mean 27.6, SD 0.5°C). The maximum load to failure was significantly higher in the twin peg group (mean 3628.41, SD 650.92N) compared to the single peg group (mean 2979, SD 781N) (P=0.016). - Interpretation - Our experiments showed higher load to failure for the twin peg design compared to the single peg design without raising the risk of heat necrosis at the interfacial bone. The twin peg component offers a save alternative to the single peg component in a cadaveric setting. | ||
| 650 | 4 | |a Anteromedial osteoarthritis | |
| 650 | 4 | |a Biomechanical study | |
| 650 | 4 | |a Implant stability | |
| 650 | 4 | |a Oxford twin-peg cemented knee replacement | |
| 650 | 4 | |a Unicompartmental knee arthroplasty | |
| 700 | 1 | |a Schwarze, Martin |d 1986- |e VerfasserIn |0 (DE-588)1081740426 |0 (DE-627)846708663 |0 (DE-576)45474482X |4 aut | |
| 700 | 1 | |a Panzram, Benjamin |d 1982- |e VerfasserIn |0 (DE-588)1015428630 |0 (DE-627)705383733 |0 (DE-576)349958912 |4 aut | |
| 700 | 1 | |a Klotz, Matthias C. M. |d 1982- |e VerfasserIn |0 (DE-588)1013229975 |0 (DE-627)663823897 |0 (DE-576)34673522X |4 aut | |
| 700 | 1 | |a Bitsch, Rudi G. |d 1970- |e VerfasserIn |0 (DE-588)131490060 |0 (DE-627)50981378X |0 (DE-576)298541726 |4 aut | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Clinical biomechanics |d Amsterdam [u.a.] : Elsevier Science, 1986 |g 55(2018), Seite 23-27 |h Online-Ressource |w (DE-627)32043740X |w (DE-600)2004518-9 |w (DE-576)261823612 |x 1879-1271 |7 nnas |a The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty |
| 773 | 1 | 8 | |g volume:55 |g year:2018 |g pages:23-27 |g extent:5 |a The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.clinbiomech.2018.04.003 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0268003318302900 |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20200116 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 6 |y j | ||
| 998 | |g 131490060 |a Bitsch, Rudi G. |m 131490060:Bitsch, Rudi G. |d 910000 |d 911460 |d 50000 |e 910000PB131490060 |e 911460PB131490060 |e 50000PB131490060 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 5 | ||
| 998 | |g 1013229975 |a Klotz, Matthias C. M. |m 1013229975:Klotz, Matthias C. M. |d 910000 |d 911460 |e 910000PK1013229975 |e 911460PK1013229975 |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 1015428630 |a Panzram, Benjamin |m 1015428630:Panzram, Benjamin |d 910000 |d 911460 |e 910000PP1015428630 |e 911460PP1015428630 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1081740426 |a Schwarze, Martin |m 1081740426:Schwarze, Martin |d 910000 |d 911460 |e 910000PS1081740426 |e 911460PS1081740426 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 998 | |g 1038723787 |a Reiner, Tobias |m 1038723787:Reiner, Tobias |d 910000 |d 911460 |e 910000PR1038723787 |e 911460PR1038723787 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1687586632 |e 3575954720 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"family":"Reiner","display":"Reiner, Tobias","role":"aut","given":"Tobias"},{"family":"Schwarze","display":"Schwarze, Martin","role":"aut","given":"Martin"},{"given":"Benjamin","role":"aut","family":"Panzram","display":"Panzram, Benjamin"},{"family":"Klotz","display":"Klotz, Matthias C. M.","role":"aut","given":"Matthias C. M."},{"given":"Rudi G.","role":"aut","display":"Bitsch, Rudi G.","family":"Bitsch"},{"role":"aut","given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 16.01.2020"],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"5 April 2018"}],"title":[{"title":"The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty","title_sort":"influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty"}],"id":{"eki":["1687586632"],"doi":["10.1016/j.clinbiomech.2018.04.003"]},"recId":"1687586632","relHost":[{"language":["eng"],"part":{"text":"55(2018), Seite 23-27","extent":"5","volume":"55","pages":"23-27","year":"2018"},"note":["Gesehen am 04.02.20"],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1986","dateIssuedDisp":"1986-","publisherPlace":"Amsterdam [u.a.]"}],"pubHistory":["1.1986 -"],"title":[{"subtitle":"a journal affiliated to the International Society of Biomechanics and the American Society of Biomechanics","title_sort":"Clinical biomechanics","title":"Clinical biomechanics"}],"disp":"The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplastyClinical biomechanics","type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"32043740X","id":{"eki":["32043740X"],"issn":["1879-1271"],"zdb":["2004518-9"]}}],"name":{"displayForm":["Tobias Reiner, Martin Schwarze, Benjamin Panzram, Matthias C. Klotz, Rudi G. Bitsch, Sebastian Jaeger"]},"physDesc":[{"extent":"5 S."}]} | ||
| SRT | |a REINERTOBIINFLUENCEO5201 | ||