The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty

Background - The twin peg femoral component was introduced for the cemented Oxford unicondylar knee to increase implant stability. The aim of this experimental study was to investigate the influence of the twin peg design on femoral interface temperature and maximum load to failure in comparison to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Reiner, Tobias (VerfasserIn) , Schwarze, Martin (VerfasserIn) , Panzram, Benjamin (VerfasserIn) , Klotz, Matthias C. M. (VerfasserIn) , Bitsch, Rudi G. (VerfasserIn) , Jäger, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 5 April 2018
In: Clinical biomechanics
Year: 2018, Jahrgang: 55, Pages: 23-27
ISSN:1879-1271
DOI:10.1016/j.clinbiomech.2018.04.003
Online-Zugang:Verlag, Volltext: https://doi.org/10.1016/j.clinbiomech.2018.04.003
Verlag: http://www.sciencedirect.com/science/article/pii/S0268003318302900
Volltext
Verfasserangaben:Tobias Reiner, Martin Schwarze, Benjamin Panzram, Matthias C. Klotz, Rudi G. Bitsch, Sebastian Jaeger

MARC

LEADER 00000caa a2200000 c 4500
001 1687586632
003 DE-627
005 20220817205458.0
007 cr uuu---uuuuu
008 200116s2018 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.clinbiomech.2018.04.003  |2 doi 
035 |a (DE-627)1687586632 
035 |a (DE-599)KXP1687586632 
035 |a (OCoLC)1341298279 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Reiner, Tobias  |d 1982-  |e VerfasserIn  |0 (DE-588)1038723787  |0 (DE-627)766370356  |0 (DE-576)392759853  |4 aut 
245 1 4 |a The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty  |c Tobias Reiner, Martin Schwarze, Benjamin Panzram, Matthias C. Klotz, Rudi G. Bitsch, Sebastian Jaeger 
264 1 |c 5 April 2018 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.01.2020 
520 |a Background - The twin peg femoral component was introduced for the cemented Oxford unicondylar knee to increase implant stability. The aim of this experimental study was to investigate the influence of the twin peg design on femoral interface temperature and maximum load to failure in comparison to the single peg design. - Methods - In this experimental study medial Oxford unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen human knees. A cemented femoral single peg component was implanted on the one side (group A) and a cemented twin peg component on the other side (group B). Cement interface temperature was continuously monitored during the procedure. Maximum tensile forces of the femoral components were measured by pull-out tests. - Findings - Maximum femoral interface temperatures did not reach critical values for heat necrosis of the bone in group A (mean 28.4, SD 1.2°C) or group B (mean 27.6, SD 0.5°C). The maximum load to failure was significantly higher in the twin peg group (mean 3628.41, SD 650.92N) compared to the single peg group (mean 2979, SD 781N) (P=0.016). - Interpretation - Our experiments showed higher load to failure for the twin peg design compared to the single peg design without raising the risk of heat necrosis at the interfacial bone. The twin peg component offers a save alternative to the single peg component in a cadaveric setting. 
650 4 |a Anteromedial osteoarthritis 
650 4 |a Biomechanical study 
650 4 |a Implant stability 
650 4 |a Oxford twin-peg cemented knee replacement 
650 4 |a Unicompartmental knee arthroplasty 
700 1 |a Schwarze, Martin  |d 1986-  |e VerfasserIn  |0 (DE-588)1081740426  |0 (DE-627)846708663  |0 (DE-576)45474482X  |4 aut 
700 1 |a Panzram, Benjamin  |d 1982-  |e VerfasserIn  |0 (DE-588)1015428630  |0 (DE-627)705383733  |0 (DE-576)349958912  |4 aut 
700 1 |a Klotz, Matthias C. M.  |d 1982-  |e VerfasserIn  |0 (DE-588)1013229975  |0 (DE-627)663823897  |0 (DE-576)34673522X  |4 aut 
700 1 |a Bitsch, Rudi G.  |d 1970-  |e VerfasserIn  |0 (DE-588)131490060  |0 (DE-627)50981378X  |0 (DE-576)298541726  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
773 0 8 |i Enthalten in  |t Clinical biomechanics  |d Amsterdam [u.a.] : Elsevier Science, 1986  |g 55(2018), Seite 23-27  |h Online-Ressource  |w (DE-627)32043740X  |w (DE-600)2004518-9  |w (DE-576)261823612  |x 1879-1271  |7 nnas  |a The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty 
773 1 8 |g volume:55  |g year:2018  |g pages:23-27  |g extent:5  |a The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty 
856 4 0 |u https://doi.org/10.1016/j.clinbiomech.2018.04.003  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0268003318302900  |x Verlag 
951 |a AR 
992 |a 20200116 
993 |a Article 
994 |a 2018 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 6  |y j 
998 |g 131490060  |a Bitsch, Rudi G.  |m 131490060:Bitsch, Rudi G.  |d 910000  |d 911460  |d 50000  |e 910000PB131490060  |e 911460PB131490060  |e 50000PB131490060  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 5 
998 |g 1013229975  |a Klotz, Matthias C. M.  |m 1013229975:Klotz, Matthias C. M.  |d 910000  |d 911460  |e 910000PK1013229975  |e 911460PK1013229975  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1015428630  |a Panzram, Benjamin  |m 1015428630:Panzram, Benjamin  |d 910000  |d 911460  |e 910000PP1015428630  |e 911460PP1015428630  |k 0/910000/  |k 1/910000/911460/  |p 3 
998 |g 1081740426  |a Schwarze, Martin  |m 1081740426:Schwarze, Martin  |d 910000  |d 911460  |e 910000PS1081740426  |e 911460PS1081740426  |k 0/910000/  |k 1/910000/911460/  |p 2 
998 |g 1038723787  |a Reiner, Tobias  |m 1038723787:Reiner, Tobias  |d 910000  |d 911460  |e 910000PR1038723787  |e 911460PR1038723787  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1687586632  |e 3575954720 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"family":"Reiner","display":"Reiner, Tobias","role":"aut","given":"Tobias"},{"family":"Schwarze","display":"Schwarze, Martin","role":"aut","given":"Martin"},{"given":"Benjamin","role":"aut","family":"Panzram","display":"Panzram, Benjamin"},{"family":"Klotz","display":"Klotz, Matthias C. M.","role":"aut","given":"Matthias C. M."},{"given":"Rudi G.","role":"aut","display":"Bitsch, Rudi G.","family":"Bitsch"},{"role":"aut","given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 16.01.2020"],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"5 April 2018"}],"title":[{"title":"The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty","title_sort":"influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty"}],"id":{"eki":["1687586632"],"doi":["10.1016/j.clinbiomech.2018.04.003"]},"recId":"1687586632","relHost":[{"language":["eng"],"part":{"text":"55(2018), Seite 23-27","extent":"5","volume":"55","pages":"23-27","year":"2018"},"note":["Gesehen am 04.02.20"],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1986","dateIssuedDisp":"1986-","publisherPlace":"Amsterdam [u.a.]"}],"pubHistory":["1.1986 -"],"title":[{"subtitle":"a journal affiliated to the International Society of Biomechanics and the American Society of Biomechanics","title_sort":"Clinical biomechanics","title":"Clinical biomechanics"}],"disp":"The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplastyClinical biomechanics","type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"32043740X","id":{"eki":["32043740X"],"issn":["1879-1271"],"zdb":["2004518-9"]}}],"name":{"displayForm":["Tobias Reiner, Martin Schwarze, Benjamin Panzram, Matthias C. Klotz, Rudi G. Bitsch, Sebastian Jaeger"]},"physDesc":[{"extent":"5 S."}]} 
SRT |a REINERTOBIINFLUENCEO5201