Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequences

As the number of magnetic resonance imaging (MRI) scanners and patients with medical implants is constantly growing, radiologists increasingly encounter metallic implant-related artifacts in MRI, resulting in reduced image quality. Therefore, the MRI suitability of implants in terms of artifact volu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hilgenfeld, Tim (VerfasserIn) , Prager, Marcel (VerfasserIn) , Schwindling, Franz Sebastian (VerfasserIn) , Jende, Johann (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Jürchott, Alexander (VerfasserIn)
Dokumenttyp: Article (Journal) Video
Sprache:Englisch
Veröffentlicht: 5/17/2018 [17.05.2018]
In: JoVE. Video journal
Year: 2018, Heft: 135, Pages: ?
ISSN:1940-087X
DOI:10.3791/57394
Schlagworte:
Online-Zugang:Verlag, Volltext: https://doi.org/10.3791/57394
Verlag, Volltext: https://www.jove.com/video/57394/protocol-for-evaluation-mri-artifacts-caused-metal-implants-to-assess
Volltext
Verfasserangaben:Tim Hilgenfeld, Marcel Prager, Franz S. Schwindling, Johann M. E. Jende, Peter Rammelsberg, Martin Bendszus, Sabine Heiland, and Alexander Juerchott

MARC

LEADER 00000cga a22000002c 4500
001 1687844348
003 DE-627
005 20230621143359.0
006 m o | |
007 cr uuu---uuuuu
008 200120s2018 xx ||| | o ||eng c
024 7 |a 10.3791/57394  |2 doi 
035 |a (DE-627)1687844348 
035 |a (DE-599)KXP1687844348 
035 |a (OCoLC)1341298188 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hilgenfeld, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1106261917  |0 (DE-627)862954398  |0 (DE-576)473950316  |4 aut 
245 1 0 |a Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequences  |c Tim Hilgenfeld, Marcel Prager, Franz S. Schwindling, Johann M. E. Jende, Peter Rammelsberg, Martin Bendszus, Sabine Heiland, and Alexander Juerchott 
264 1 |c 5/17/2018 [17.05.2018] 
300 |a 1 Online-Ressource (1 Videodatei, 7:42 min)  |b farbig 
336 |a Text  |b txt  |2 rdacontent 
336 |a zweidimensionales bewegtes Bild  |b tdi  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published: 5/17/2018 
500 |a Enthält auch Textversion 
500 |a Gesehen am 20.01.2020 
500 |a Wissenschaftlicher Film. Deutschland. 2018 
520 |a As the number of magnetic resonance imaging (MRI) scanners and patients with medical implants is constantly growing, radiologists increasingly encounter metallic implant-related artifacts in MRI, resulting in reduced image quality. Therefore, the MRI suitability of implants in terms of artifact volume, as well as the development of pulse sequences to reduce image artifacts, are becoming more and more important. Here, we present a comprehensive protocol which allows for a standardized evaluation of the artifact volume of implants on MRI. Furthermore, this protocol can be used to analyze the vulnerability of different pulse sequences to artifacts. The proposed protocol can be applied to T1- and T2-weighted images with or without fat-suppression and all passive implants. Furthermore, the procedure enables the separate and three-dimensional identification of signal loss and pile-up artifacts. As previous investigations differed greatly in evaluation methods, the comparability of their results was limited. Thus, standardized measurements of MRI artifact volumes are necessary to provide better comparability. This may improve the development of the MRI suitability of implants and better pulse sequences to finally improve patient care 
655 7 |a Film  |0 (DE-588)4017102-4  |0 (DE-627)104559683  |0 (DE-576)208918531  |2 gnd-content 
700 1 |a Prager, Marcel  |e VerfasserIn  |0 (DE-588)1106261631  |0 (DE-627)86295357X  |0 (DE-576)473950030  |4 aut 
700 1 |a Schwindling, Franz Sebastian  |d 1986-  |e VerfasserIn  |0 (DE-588)1036843572  |0 (DE-627)751703613  |0 (DE-576)38697926X  |4 aut 
700 1 |a Jende, Johann  |e VerfasserIn  |0 (DE-588)1161484809  |0 (DE-627)1024781569  |0 (DE-576)506571025  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Jürchott, Alexander  |e VerfasserIn  |0 (DE-588)1167429230  |0 (DE-627)1031103090  |0 (DE-576)511136137  |4 aut 
773 0 8 |i Enthalten in  |t JoVE. Video journal  |d [Erscheinungsort nicht ermittelbar] : [Verlag nicht ermittelbar], 2006  |g (2018), 135, Artikel-ID e57394, Seite ?  |h Online-Ressource  |w (DE-627)521454778  |w (DE-600)2259946-0  |w (DE-576)338522980  |x 1940-087X  |7 nngs  |a Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequences 
773 1 8 |g year:2018  |g number:135  |g elocationid:e57394  |g pages:?  |a Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequences 
856 4 0 |u https://doi.org/10.3791/57394  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.jove.com/video/57394/protocol-for-evaluation-mri-artifacts-caused-metal-implants-to-assess  |x Verlag  |3 Volltext 
935 |c vide 
937 |a Wissenschaftlicher Film  |b Deutschland  |c 2018 
951 |a AR 
992 |a 20200120 
993 |a Video 
994 |a 2018 
998 |g 1167429230  |a Jürchott, Alexander  |m 1167429230:Jürchott, Alexander  |d 910000  |d 911100  |e 910000PJ1167429230  |e 911100PJ1167429230  |k 0/910000/  |k 1/910000/911100/  |p 8  |y j 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 7 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 1161484809  |a Jende, Johann  |m 1161484809:Jende, Johann  |d 910000  |d 911100  |e 910000PJ1161484809  |e 911100PJ1161484809  |k 0/910000/  |k 1/910000/911100/  |p 4 
998 |g 1036843572  |a Schwindling, Franz Sebastian  |m 1036843572:Schwindling, Franz Sebastian  |d 910000  |d 910800  |e 910000PS1036843572  |e 910800PS1036843572  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 1106261631  |a Prager, Marcel  |m 1106261631:Prager, Marcel  |d 910000  |d 911100  |e 910000PP1106261631  |e 911100PP1106261631  |k 0/910000/  |k 1/910000/911100/  |p 2 
998 |g 1106261917  |a Hilgenfeld, Tim  |m 1106261917:Hilgenfeld, Tim  |d 910000  |d 911100  |e 910000PH1106261917  |e 911100PH1106261917  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1687844348  |e 3576707832 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Tim Hilgenfeld, Marcel Prager, Franz S. Schwindling, Johann M. E. Jende, Peter Rammelsberg, Martin Bendszus, Sabine Heiland, and Alexander Juerchott"]},"id":{"eki":["1687844348"],"doi":["10.3791/57394"]},"recId":"1687844348","physDesc":[{"extent":"1 Online-Ressource (1 Videodatei, 7:42 min) S.","noteIll":"farbig"}],"origin":[{"dateIssuedDisp":"5/17/2018 [17.05.2018]","dateIssuedKey":"2018"}],"relHost":[{"origin":[{"dateIssuedKey":"2006","dateIssuedDisp":"2006-","publisherPlace":"[Erscheinungsort nicht ermittelbar]","publisher":"[Verlag nicht ermittelbar]"}],"title":[{"partname":"Video journal","title":"JoVE","title_sort":"JoVE"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Gesehen am 10.02.25","Inhaltliche Gliederung in: Behavior; Biochemistry; Bioengineering; Biology; Cancer research; Chemistry; Developmental biology; Engineering; Environment; Genetics; Immunology and infection; Medicine; Neuroscience"],"recId":"521454778","physDesc":[{"extent":"Online-Ressource"}],"disp":"Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequencesJoVE. Video journal","pubHistory":["1.2006 -"],"titleAlt":[{"title":"JoVE journal"},{"title":"JoVE journal Biology"},{"title":"JoVE journal Medicine"},{"title":"JoVE journal Behavior"},{"title":"JoVE journal Biochemistry"},{"title":"JoVE journal Bioengineering"},{"title":"JoVE journal Cancer research"},{"title":"JoVE journal Chemistry"},{"title":"JoVE journal Developmental biology"},{"title":"JoVE journal Engineering"},{"title":"JoVE journal Environment"},{"title":"JoVE journal Genetics"},{"title":"JoVE journal Immunology and infection"},{"title":"JoVE journal Neuroscience"},{"title":"Journal of visualized experiments"}],"id":{"issn":["1940-087X"],"eki":["521454778"],"zdb":["2259946-0"]},"part":{"text":"(2018), 135, Artikel-ID e57394, Seite ?","issue":"135","pages":"?","year":"2018"}}],"person":[{"display":"Hilgenfeld, Tim","family":"Hilgenfeld","role":"aut","given":"Tim"},{"display":"Prager, Marcel","family":"Prager","given":"Marcel","role":"aut"},{"display":"Schwindling, Franz Sebastian","role":"aut","given":"Franz Sebastian","family":"Schwindling"},{"family":"Jende","role":"aut","given":"Johann","display":"Jende, Johann"},{"display":"Rammelsberg, Peter","given":"Peter","role":"aut","family":"Rammelsberg"},{"family":"Bendszus","given":"Martin","role":"aut","display":"Bendszus, Martin"},{"display":"Heiland, Sabine","family":"Heiland","role":"aut","given":"Sabine"},{"display":"Jürchott, Alexander","given":"Alexander","role":"aut","family":"Jürchott"}],"title":[{"title":"Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequences","title_sort":"Protocol for the evaluation of MRI artifacts caused by metal implants to assess the suitability of implants and the vulnerability of pulse sequences"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["Published: 5/17/2018","Enthält auch Textversion","Gesehen am 20.01.2020","Wissenschaftlicher Film. Deutschland. 2018"]} 
SRT |a HILGENFELDPROTOCOLFO5172