Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertension

BACKGROUND - We examined safety and long-term outcomes of intravenous treprostinil administered via the implantable LENUS Pro pump in patients with severe pulmonary hypertension (PH). - METHODS - Patients with PH undergoing pump implantation between December 2009 and October 2016 in German referral...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Richter, Manuel Jonas (VerfasserIn) , Harutyunova, Satenik (VerfasserIn) , Grünig, Ekkehard (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 21 June 2018
In: The journal of heart and lung transplantation
Year: 2018, Jahrgang: 37, Heft: 10, Pages: 1235-1244
ISSN:1557-3117
DOI:10.1016/j.healun.2018.06.006
Online-Zugang:Verlag, Volltext: https://doi.org/10.1016/j.healun.2018.06.006
Verlag: http://www.sciencedirect.com/science/article/pii/S1053249818315079
Volltext
Verfasserangaben:Manuel J. Richter, Satenik Harutyunova, Tom Bollmann, Simon Classen, Henning Gall, MD, Felix Gerhardt, Friedrich Grimminger, Jan Grimminger, Ekkehard Grünig, Stefan Guth, Michael Halank, Alexander Heine, Marius M. Hoeper, Hans Klose, Tobias J. Lange, Katrin Meyer, Claus Neurohr, Kai Nickolaus, Karen M. Olsson, Christian F. Opitz, Stephan Rosenkranz, Hans-Jürgen Seyfarth, Christian Warnke, Christoph Wiedenroth, Hossein A. Ghofrani, and Ralf Ewert

MARC

LEADER 00000caa a2200000 c 4500
001 1689251638
003 DE-627
005 20230427063309.0
007 cr uuu---uuuuu
008 200204s2018 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.healun.2018.06.006  |2 doi 
035 |a (DE-627)1689251638 
035 |a (DE-599)KXP1689251638 
035 |a (OCoLC)1341303828 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Richter, Manuel Jonas  |e VerfasserIn  |0 (DE-588)1025802012  |0 (DE-627)724279687  |0 (DE-576)370795393  |4 aut 
245 1 0 |a Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertension  |c Manuel J. Richter, Satenik Harutyunova, Tom Bollmann, Simon Classen, Henning Gall, MD, Felix Gerhardt, Friedrich Grimminger, Jan Grimminger, Ekkehard Grünig, Stefan Guth, Michael Halank, Alexander Heine, Marius M. Hoeper, Hans Klose, Tobias J. Lange, Katrin Meyer, Claus Neurohr, Kai Nickolaus, Karen M. Olsson, Christian F. Opitz, Stephan Rosenkranz, Hans-Jürgen Seyfarth, Christian Warnke, Christoph Wiedenroth, Hossein A. Ghofrani, and Ralf Ewert 
264 1 |c 21 June 2018 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 04.02.2020 
520 |a BACKGROUND - We examined safety and long-term outcomes of intravenous treprostinil administered via the implantable LENUS Pro pump in patients with severe pulmonary hypertension (PH). - METHODS - Patients with PH undergoing pump implantation between December 2009 and October 2016 in German referral centers were retrospectively analyzed (end of follow-up: May 2017). The primary objective was to determine long-term safety of the implantable pump. Secondary end points were 3-year survival and prognostic relevance of pre-implantation hemodynamics. - RESULTS - We monitored 129 patients (120 with pulmonary arterial hypertension, 1 with PH due to lung diseases, and 8 with inoperable chronic thromboembolic PH) for 260 patient-years (median follow-up, 19 months; interquartile range, 11-34 months). There were 82 complications/peri-procedural events in 60 patients; of these, 57 were serious adverse events (0.60 per 1,000 treatment-days), including 2 periprocedural deaths due to right heart failure. The incidence of complications related to the pump, catheter, infection, and pump pocket per 1,000 treatment-days was 0.074, 0.264, 0.032 (3 local infections; no bloodstream infections), and 0.380, respectively. Three-year overall and transplant-free survival were 66.5% and 55.7%, respectively (39 patients died; 16 underwent lung transplantation). Baseline cardiac index independently predicted transplant-free survival (multivariate hazard ratio, 1.90; 95% confidence interval, 1.11-3.28; p=0.019; n=95). - CONCLUSIONS - Our data suggest that intravenous treprostinil via the LENUS Pro pump in advanced PH is associated with a very low risk of bloodstream infections, but other serious adverse events may occur. Therefore, this therapy needs standardization and should be offered in specialized PH centers only. Further technical advances of the pump system and prospective studies are needed. 
650 4 |a mortality 
650 4 |a pulmonary hypertension 
650 4 |a pump 
650 4 |a survival 
650 4 |a treprostinil 
700 1 |a Harutyunova, Satenik  |d 1982-  |e VerfasserIn  |0 (DE-588)1119826160  |0 (DE-627)872910342  |0 (DE-576)480011184  |4 aut 
700 1 |a Grünig, Ekkehard  |e VerfasserIn  |0 (DE-588)112535801  |0 (DE-627)618892605  |0 (DE-576)31856694X  |4 aut 
773 0 8 |i Enthalten in  |t The journal of heart and lung transplantation  |d Amsterdam [u.a.] : Elsevier Science, 1999  |g 37(2018), 10, Seite 1235-1244  |h Online-Ressource  |w (DE-627)306659743  |w (DE-600)1500494-6  |w (DE-576)260773786  |x 1557-3117  |7 nnas  |a Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertension 
773 1 8 |g volume:37  |g year:2018  |g number:10  |g pages:1235-1244  |g extent:10  |a Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertension 
856 4 0 |u https://doi.org/10.1016/j.healun.2018.06.006  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1053249818315079  |x Verlag 
951 |a AR 
992 |a 20200204 
993 |a Article 
994 |a 2018 
998 |g 112535801  |a Grünig, Ekkehard  |m 112535801:Grünig, Ekkehard  |d 910000  |d 950000  |d 950900  |e 910000PG112535801  |e 950000PG112535801  |e 950900PG112535801  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 9 
998 |g 1119826160  |a Harutyunova, Satenik  |m 1119826160:Harutyunova, Satenik  |d 910000  |d 950000  |d 950900  |e 910000PH1119826160  |e 950000PH1119826160  |e 950900PH1119826160  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 2 
999 |a KXP-PPN1689251638  |e 3587385351 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Manuel J. Richter, Satenik Harutyunova, Tom Bollmann, Simon Classen, Henning Gall, MD, Felix Gerhardt, Friedrich Grimminger, Jan Grimminger, Ekkehard Grünig, Stefan Guth, Michael Halank, Alexander Heine, Marius M. Hoeper, Hans Klose, Tobias J. Lange, Katrin Meyer, Claus Neurohr, Kai Nickolaus, Karen M. Olsson, Christian F. Opitz, Stephan Rosenkranz, Hans-Jürgen Seyfarth, Christian Warnke, Christoph Wiedenroth, Hossein A. Ghofrani, and Ralf Ewert"]},"recId":"1689251638","note":["Gesehen am 04.02.2020"],"origin":[{"dateIssuedDisp":"21 June 2018","dateIssuedKey":"2018"}],"language":["eng"],"id":{"eki":["1689251638"],"doi":["10.1016/j.healun.2018.06.006"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"given":"Manuel Jonas","display":"Richter, Manuel Jonas","family":"Richter","role":"aut"},{"role":"aut","given":"Satenik","display":"Harutyunova, Satenik","family":"Harutyunova"},{"display":"Grünig, Ekkehard","family":"Grünig","given":"Ekkehard","role":"aut"}],"physDesc":[{"extent":"10 S."}],"title":[{"title":"Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertension","title_sort":"Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertension"}],"relHost":[{"origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"[1999?]-","publisherPlace":"Amsterdam [u.a.]"}],"id":{"eki":["306659743"],"issn":["1557-3117"],"zdb":["1500494-6"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"part":{"extent":"10","year":"2018","issue":"10","volume":"37","text":"37(2018), 10, Seite 1235-1244","pages":"1235-1244"},"title":[{"title_sort":"journal of heart and lung transplantation","title":"The journal of heart and lung transplantation","subtitle":"a forum that includes basic science, the failing heart, and advanced lung disease ; the official publication of the International Society for Heart and Lung Transplantation"}],"physDesc":[{"extent":"Online-Ressource"}],"disp":"Long-term safety and outcome of intravenous treprostinil via an implanted pump in pulmonary hypertensionThe journal of heart and lung transplantation","pubHistory":["Nachgewiesen 18.1999 -"],"recId":"306659743","note":["Gesehen am 15.01.20","Ungezählte Beil.: Supplement"]}]} 
SRT |a RICHTERMANLONGTERMSA2120