Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographer
Purpose: To compare measurements of anterior and posterior keratometric values, using a color light-emitting diode corneal topographer and a dual rotating Scheimpflug-Placido topographer. Methods: Anterior and posterior corneal index measurements were performed using a color light-emitting diode cor...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
27 Dec 2018
|
| In: |
Journal of ophthalmology
Year: 2018, Pages: 1-7 |
| ISSN: | 2090-0058 |
| DOI: | 10.1155/2018/6764805 |
| Online Access: | Verlag, Volltext: https://doi.org/10.1155/2018/6764805 Verlag: https://www.hindawi.com/journals/joph/2018/6764805/ |
| Author Notes: | Jae Hyuck Lee, Yong Woo Lee, Jong Soo Lee, Michael C. Knorz, Gerd U. Auffarth, and Chul Young Choi |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1690935308 | ||
| 003 | DE-627 | ||
| 005 | 20220818000455.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200225s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1155/2018/6764805 |2 doi | |
| 035 | |a (DE-627)1690935308 | ||
| 035 | |a (DE-599)KXP1690935308 | ||
| 035 | |a (OCoLC)1341308125 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Lee, Jae Hyuck |e VerfasserIn |0 (DE-588)1205341897 |0 (DE-627)1690935960 |4 aut | |
| 245 | 1 | 0 | |a Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographer |c Jae Hyuck Lee, Yong Woo Lee, Jong Soo Lee, Michael C. Knorz, Gerd U. Auffarth, and Chul Young Choi |
| 264 | 1 | |c 27 Dec 2018 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 25.02.2020 | ||
| 520 | |a Purpose: To compare measurements of anterior and posterior keratometric values, using a color light-emitting diode corneal topographer and a dual rotating Scheimpflug-Placido topographer. Methods: Anterior and posterior corneal index measurements were performed using a color light-emitting diode corneal topographer (Cassini) and a dual rotating Scheimpflug-Placido topographer (Galilei G4) and then compared. The paired t-test, intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to evaluate the agreement between measurements. Results: Sixty postrefractive surgery eyes and 60 normal eyes were evaluated. Both the color light-emitting diode corneal topographer and the dual rotating Scheimpflug-Placido topographer provided highly repeatable corneal measurements (ICC > 0.969). The agreement levels between the 2 devices for anterior corneal power, astigmatism magnitude, and J0 and J45 values were ICC > 0.906 for the total group. However, the ICC values for posterior corneal power, astigmatism magnitude, and J0 and J45 values were lower than 0.681 for the total group. Conclusions: The anterior keratometric values obtained by the color light-emitting diode corneal topographer and the dual rotating Scheimpflug-Placido topographer showed high agreement levels, but the posterior keratometric values showed lower agreement levels. | ||
| 700 | 1 | |a Knorz, Michael C. |e VerfasserIn |0 (DE-588)112841988 |0 (DE-627)502583126 |0 (DE-576)289744253 |4 aut | |
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of ophthalmology |d [Hoboken, NJ] : Wiley, 2009 |g (2018), Artikel-ID 6764805, Seite 1-7 |h Online-Ressource |w (DE-627)62318270X |w (DE-600)2546525-9 |w (DE-576)321467523 |x 2090-0058 |7 nnas |a Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographer |
| 773 | 1 | 8 | |g year:2018 |g elocationid:6764805 |g pages:1-7 |g extent:7 |a Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographer |
| 856 | 4 | 0 | |u https://doi.org/10.1155/2018/6764805 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://www.hindawi.com/journals/joph/2018/6764805/ |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20200225 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 4 | ||
| 998 | |g 112841988 |a Knorz, Michael C. |m 112841988:Knorz, Michael C. |d 60000 |d 61700 |e 60000PK112841988 |e 61700PK112841988 |k 0/60000/ |k 1/60000/61700/ |p 4 | ||
| 999 | |a KXP-PPN1690935308 |e 3598199414 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"note":["Gesehen am 25.02.2020"],"physDesc":[{"extent":"7 S."}],"recId":"1690935308","relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"62318270X","physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 08.09.2021"],"origin":[{"publisher":"Wiley ; Hindawi","dateIssuedKey":"2024","publisherPlace":"[Hoboken, NJ] ; New York, NY","dateIssuedDisp":"2024-"}],"part":{"pages":"1-7","extent":"7","text":"(2018), Artikel-ID 6764805, Seite 1-7","year":"2018"},"id":{"zdb":["2546525-9"],"issn":["2090-0058"],"eki":["62318270X"]},"disp":"Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographerJournal of ophthalmology","title":[{"title":"Journal of ophthalmology","title_sort":"Journal of ophthalmology"}],"language":["eng"],"pubHistory":["2009 -"]}],"title":[{"title":"Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographer","title_sort":"Comparison of color light-emitting diode corneal topographer and dual rotating Scheimpflug-placido topographer"}],"name":{"displayForm":["Jae Hyuck Lee, Yong Woo Lee, Jong Soo Lee, Michael C. Knorz, Gerd U. Auffarth, and Chul Young Choi"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1155/2018/6764805"],"eki":["1690935308"]},"person":[{"family":"Lee","role":"aut","display":"Lee, Jae Hyuck","given":"Jae Hyuck"},{"given":"Michael C.","role":"aut","display":"Knorz, Michael C.","family":"Knorz"},{"given":"Gerd U.","role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth"}],"origin":[{"dateIssuedDisp":"27 Dec 2018","dateIssuedKey":"2018"}]} | ||
| SRT | |a LEEJAEHYUCCOMPARISON2720 | ||