FRoG: a fast robust analytical dose engine on GPU for p, 4He, 12C and 16O particle therapy

Radiotherapy with protons and heavier ions landmarks a novel era in the field of highprecision cancer therapy. To identify patients most benefiting from this technologically demanding therapy, fast assessment of comparative treatment plans utilizing different ion species is urgently needed. Moreover...

Full description

Saved in:
Bibliographic Details
Main Author: Mein, Stewart (Author)
Format: Book/Monograph Thesis
Language:English
Published: Heidelberg 19 Feb. 2020
DOI:10.11588/heidok.00027888
Subjects:
Online Access:Resolving-System, kostenfrei: https://nbn-resolving.de/urn:nbn:de:bsz:16-heidok-278886
Resolving-System, kostenfrei: http://dx.doi.org/10.11588/heidok.00027888
Verlag, kostenfrei, Volltext: http://www.ub.uni-heidelberg.de/archiv/27888
Resolving-System: https://nbn-resolving.org/urn:nbn:de:bsz:16-heidok-278886
Langzeitarchivierung Nationalbibliothek: https://d-nb.info/1205072020/34
Resolving-System: https://doi.org/10.11588/heidok.00027888
Get full text
Author Notes:put forward by Stewart "Mac" Biedeman Mein IV ; referees: Prof. Dr. Dr.Jürgen Debus, Prof. Dr. Oliver Jäkel

MARC

LEADER 00000cam a2200000 c 4500
001 1691055816
003 DE-627
005 20230107223637.0
007 cr uuu---uuuuu
008 200226s2020 gw |||||om 00| ||eng c
016 7 |a 1205072020  |2 DE-101 
024 7 |a urn:nbn:de:bsz:16-heidok-278886  |2 urn 
024 7 |a 10.11588/heidok.00027888  |2 doi 
035 |a (DE-627)1691055816 
035 |a (DE-599)KXP1691055816 
035 |a (OCoLC)1141857624 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
044 |c XA-DE-BW 
082 0 |a 615.8  |q DE-101 
082 0 4 |a 610  |q DE-101 
084 |a 29  |2 sdnb 
084 |a 33  |2 sdnb 
100 1 |a Mein, Stewart  |d 1989-  |e VerfasserIn  |0 (DE-588)1156925304  |0 (DE-627)1019871873  |0 (DE-576)502506105  |4 aut 
245 1 0 |a FRoG: a fast robust analytical dose engine on GPU for p, 4He, 12C and 16O particle therapy  |c put forward by Stewart "Mac" Biedeman Mein IV ; referees: Prof. Dr. Dr.Jürgen Debus, Prof. Dr. Oliver Jäkel 
246 3 3 |a FRoG: a fast robust analytical dose engine on GPU for p, 4 He, 12 C and 16 O particle therapy 
264 1 |a Heidelberg  |c 19 Feb. 2020 
300 |a 1 Online-Ressource (VI, 135 Seiten)  |b Illustrationen, Diagramme 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Im Titel ist die 4 in "4He", die 12 in "12C" und die 16 in "16O" hochgestellt 
502 |b Dissertation  |c Ruperto-Carola University of Heidelberg  |d 2020 
520 |a Radiotherapy with protons and heavier ions landmarks a novel era in the field of highprecision cancer therapy. To identify patients most benefiting from this technologically demanding therapy, fast assessment of comparative treatment plans utilizing different ion species is urgently needed. Moreover, to overcome uncertainties of actual in-vivo physical dose distribution and biological effects elicited by different radiation qualities, development of a reliable high-throughput algorithm is required. To this end, we engineered a unique graphics processing unit (GPU) based software architecture allowing rapid and robust dose calculation. Fast dose Recalculation on GPU (FRoG) currently operates with four particle beams, i.e., raster-scanning proton, helium, carbon and oxygen ions. Designed to perform fast and accurate calculations for both physical and biophysical quantities, FRoG operates an advanced analytical pencil beam algorithm using parallelized procedures on a GPU. Clinicians and medical physicists can assess both dose and dose-averaged linear energy transfer (LET) distributions for proton therapy (and in turn effective dose by applying variable RBE schemes) to further scrutinize plans for acceptance or potential re-planning purposes within minutes. In addition, various biological model predictions are readily accessible for heavy ion therapy, such as the local effect model (LEM) and microdosimetric kinetic model (MKM). FRoG has been extensively benchmarked against gold standard Monte Carlo simulations and experimental data. Evaluating against commercial treatment planning systems demonstrates the strength of FRoG in better predicting dose distributions in complex clinical settings. In preparation for the upcoming translation of novel ions, case-/disease-specific ion-beam selection and advanced multi-particle treatment modalities at the Heidelberg Ion-beam Therapy Center (HIT), we quantified the accuracy limits in particle therapy treatment planning under complex heterogeneous conditions for the four ions (p, 4He, 12C, 16O) for various dose engines, both analytical algorithms and Monte Carlo code. Devised in-house, FRoG landmarks the first GPU-based treatment planning system (non commercial) for raster-scanning 4He ion beams, with an official treatment program set for early 2020. Since its inception, FRoG has been installed and is currently in operation clinically at four centers across Europe: HIT (Heidelberg, Germany), CNAO (Pavia, Italy) , Aarhus (Denmark) and the Normandy Proton Therapy Center (Caen, France). Here, the development and validation of FRoG as well as clinical investigations and advanced topics in particle therapy dose calculation are covered. The thesis is presented in cumulative format and comprises four peer reviewed publications. 
546 |a Mit einer Zusammenfassung in deutscher und englischer Sprache 
655 7 |a Hochschulschrift  |0 (DE-588)4113937-9  |0 (DE-627)105825778  |0 (DE-576)209480580  |2 gnd-content 
700 1 |a Debus, Jürgen  |d 1964-  |e AkademischeR BetreuerIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 dgs 
751 |a Heidelberg  |0 (DE-588)4023996-2  |0 (DE-627)106300814  |0 (DE-576)208952578  |4 uvp 
776 0 8 |i Erscheint auch als  |n Druck-Ausgabe  |a Mein, Stewart, 1989 -   |t FRoG: a fast robust analytical dose engine on GPU for p, 4He, 12C and 16O particle therapy  |d Heidelberg, 2020  |h i, VI, 135 Seiten  |w (DE-627)1698147503 
856 4 0 |u https://nbn-resolving.de/urn:nbn:de:bsz:16-heidok-278886  |q application/pdf  |x Resolving-System  |z kostenfrei 
856 4 0 |u http://dx.doi.org/10.11588/heidok.00027888  |x Resolving-System  |z kostenfrei 
856 4 0 |u http://www.ub.uni-heidelberg.de/archiv/27888  |q application/pdf  |x Verlag  |z kostenfrei  |3 Volltext 
856 4 0 |u https://nbn-resolving.org/urn:nbn:de:bsz:16-heidok-278886  |v 2020-03-04  |x Resolving-System 
856 4 0 |u https://d-nb.info/1205072020/34  |v 2020-03-04  |x Langzeitarchivierung Nationalbibliothek 
856 4 0 |u https://doi.org/10.11588/heidok.00027888  |v 2020-03-04  |x Resolving-System 
912 |a GBV-ODiss 
951 |a BO 
992 |a 20200226 
993 |a Thesis 
994 |a 2020 
998 |g 1156925304  |a Mein, Stewart  |m 1156925304:Mein, Stewart  |d 130000  |d 130001  |e 130000PM1156925304  |e 130001PM1156925304  |k 0/130000/  |k 1/130000/130001/  |p 1  |x j  |y j 
999 |a KXP-PPN1691055816  |e 3598585012 
BIB |a Y 
JSO |a {"titleAlt":[{"title":"FRoG: a fast robust analytical dose engine on GPU for p, 4 He, 12 C and 16 O particle therapy"}],"physDesc":[{"noteIll":"Illustrationen, Diagramme","extent":"1 Online-Ressource (VI, 135 Seiten)"}],"person":[{"display":"Mein, Stewart","family":"Mein","given":"Stewart","roleDisplay":"VerfasserIn","role":"aut"},{"roleDisplay":"AkademischeR BetreuerIn","role":"dgs","given":"Jürgen","family":"Debus","display":"Debus, Jürgen"}],"name":{"displayForm":["put forward by Stewart \"Mac\" Biedeman Mein IV ; referees: Prof. Dr. Dr.Jürgen Debus, Prof. Dr. Oliver Jäkel"]},"title":[{"title":"FRoG: a fast robust analytical dose engine on GPU for p, 4He, 12C and 16O particle therapy","title_sort":"FRoG: a fast robust analytical dose engine on GPU for p, 4He, 12C and 16O particle therapy"}],"language":["eng"],"note":["Im Titel ist die 4 in \"4He\", die 12 in \"12C\" und die 16 in \"16O\" hochgestellt"],"recId":"1691055816","type":{"bibl":"thesis","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"19 Feb. 2020","dateIssuedKey":"2020","publisherPlace":"Heidelberg"}],"id":{"uri":["urn:nbn:de:bsz:16-heidok-278886"],"eki":["1691055816"],"doi":["10.11588/heidok.00027888"]},"noteThesis":["Dissertation. - Ruperto-Carola University of Heidelberg. - 2020"]} 
SRT |a MEINSTEWARFROGAFASTR1920