Measurement of isocenter accuracy and image distortion in magnetic resonance-guided radiotherapy
Magnetic resonance (MR)-guided radiotherapy involves complex irradiation- and imaging devices (MR-Linacs), as well as complex treatment procedures. To assure accurate patient treatments, both have to be tested for proper functioning. Here, new methods to simultane-ously measure the isocenter alignme...
Gespeichert in:
| 1. Verfasser: | |
|---|---|
| Dokumenttyp: | Buch/Monographie Hochschulschrift |
| Sprache: | Englisch |
| Veröffentlicht: |
Heidelberg
18 Feb. 2020
|
| DOI: | 10.11588/heidok.00027896 |
| Schlagworte: | |
| Online-Zugang: | Resolving-System, kostenfrei: https://nbn-resolving.de/urn:nbn:de:bsz:16-heidok-278967 Resolving-System, kostenfrei: http://dx.doi.org/10.11588/heidok.00027896 Verlag, kostenfrei, Volltext: http://www.ub.uni-heidelberg.de/archiv/27896 Resolving-System: https://nbn-resolving.org/urn:nbn:de:bsz:16-heidok-278967 Langzeitarchivierung Nationalbibliothek: https://d-nb.info/1205002782/34 Resolving-System: https://doi.org/10.11588/heidok.00027896 |
| Verfasserangaben: | put forward by Stefan Dorsch,M. Sc. ; referess: Prof. Dr. Joao Seco, Prof. Dr. Chrisitan Karger |
MARC
| LEADER | 00000cam a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1691060178 | ||
| 003 | DE-627 | ||
| 005 | 20230107223614.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200226s2020 gw |||||om 00| ||eng c | ||
| 016 | 7 | |a 1205002782 |2 DE-101 | |
| 024 | 7 | |a urn:nbn:de:bsz:16-heidok-278967 |2 urn | |
| 024 | 7 | |a 10.11588/heidok.00027896 |2 doi | |
| 035 | |a (DE-627)1691060178 | ||
| 035 | |a (DE-599)KXP1691060178 | ||
| 035 | |a (OCoLC)1141858724 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 044 | |c XA-DE-BW | ||
| 082 | 0 | |a 538.3 |q DE-101 | |
| 082 | 0 | 4 | |a 530 |q DE-101 |
| 084 | |a 29 |2 sdnb | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Dorsch, Stefan |d 1989- |e VerfasserIn |0 (DE-588)1187162752 |0 (DE-627)1666316008 |4 aut | |
| 245 | 1 | 0 | |a Measurement of isocenter accuracy and image distortion in magnetic resonance-guided radiotherapy |c put forward by Stefan Dorsch,M. Sc. ; referess: Prof. Dr. Joao Seco, Prof. Dr. Chrisitan Karger |
| 264 | 1 | |a Heidelberg |c 18 Feb. 2020 | |
| 300 | |a 1 Online-Ressource (iii, 97 Seiten) |b Illustrationen, Diagramme | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 502 | |b Dissertation |c Ruperto-Carola University of Heidelberg |d 2020 | ||
| 520 | |a Magnetic resonance (MR)-guided radiotherapy involves complex irradiation- and imaging devices (MR-Linacs), as well as complex treatment procedures. To assure accurate patient treatments, both have to be tested for proper functioning. Here, new methods to simultane-ously measure the isocenter alignment accuracy and the geometric image distortions of clin-ical MR-Linacs were developed. A new phantom was designed, which includes a polymer dosimetry gel-container to visualize the beams from a star shot and to identify the radiation isocenter position in MR as well as a regular grid used to visualize the MR image distortions in 3D. It was found that the gel can be evaluated immediately after irradiation with a geo-metric accuracy comparable to that of radiochromic films. The method was applied on a clinical 0.35 T MR-Linac and the isocenter alignment accuracy in 3D was found to be (0.8 ± 0.9) mm. The spatial image distortions after machine-specific correction were (0.60 ± 0.28) mm and 99.82% of the 1330 evaluated control points within a 140 mm sphere had devi-ations below 1.5 mm. Finally, a 3D printing materials and printing technique, compatible with the polymer dosimetry gel, was identified for future designs of anthropomorphic phantoms to be used in end-to-end tests in MR-guided radiotherapy. | ||
| 546 | |a Mit einer Zusammenfassung in deutscher und englischer Sprache | ||
| 655 | 7 | |a Hochschulschrift |0 (DE-588)4113937-9 |0 (DE-627)105825778 |0 (DE-576)209480580 |2 gnd-content | |
| 700 | 1 | |a Seco, Joao |e AkademischeR BetreuerIn |0 (DE-588)1120955866 |0 (DE-627)874146615 |0 (DE-576)480627010 |4 dgs | |
| 751 | |a Heidelberg |0 (DE-588)4023996-2 |0 (DE-627)106300814 |0 (DE-576)208952578 |4 uvp | ||
| 776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |a Dorsch, Stefan, 1989 - |t Measurement of isocenter accuracy and image distortion in magnetic resonance-guided radiotherapy |d Heidelberg, 2020 |h iii, 97 Seiten |w (DE-627)1698138385 |
| 856 | 4 | 0 | |u https://nbn-resolving.de/urn:nbn:de:bsz:16-heidok-278967 |q application/pdf |x Resolving-System |z kostenfrei |
| 856 | 4 | 0 | |u http://dx.doi.org/10.11588/heidok.00027896 |x Resolving-System |z kostenfrei |
| 856 | 4 | 0 | |u http://www.ub.uni-heidelberg.de/archiv/27896 |q application/pdf |x Verlag |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://nbn-resolving.org/urn:nbn:de:bsz:16-heidok-278967 |v 2020-03-04 |x Resolving-System |
| 856 | 4 | 0 | |u https://d-nb.info/1205002782/34 |v 2020-03-04 |x Langzeitarchivierung Nationalbibliothek |
| 856 | 4 | 0 | |u https://doi.org/10.11588/heidok.00027896 |v 2020-03-04 |x Resolving-System |
| 912 | |a GBV-ODiss | ||
| 951 | |a BO | ||
| 992 | |a 20200226 | ||
| 993 | |a Thesis | ||
| 994 | |a 2020 | ||
| 998 | |g 1187162752 |a Dorsch, Stefan |m 1187162752:Dorsch, Stefan |d 130000 |d 130001 |e 130000PD1187162752 |e 130001PD1187162752 |k 0/130000/ |k 1/130000/130001/ |p 1 |x j |y j | ||
| 999 | |a KXP-PPN1691060178 |e 3598603673 | ||
| BIB | |a Y | ||
| JSO | |a {"person":[{"display":"Dorsch, Stefan","given":"Stefan","role":"aut","family":"Dorsch"},{"display":"Seco, Joao","given":"Joao","role":"dgs","family":"Seco"}],"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"18 Feb. 2020","publisherPlace":"Heidelberg"}],"name":{"displayForm":["put forward by Stefan Dorsch,M. Sc. ; referess: Prof. Dr. Joao Seco, Prof. Dr. Chrisitan Karger"]},"language":["eng"],"type":{"bibl":"thesis","media":"Online-Ressource"},"title":[{"title_sort":"Measurement of isocenter accuracy and image distortion in magnetic resonance-guided radiotherapy","title":"Measurement of isocenter accuracy and image distortion in magnetic resonance-guided radiotherapy"}],"id":{"eki":["1691060178"],"uri":["urn:nbn:de:bsz:16-heidok-278967"],"doi":["10.11588/heidok.00027896"]},"noteThesis":["Dissertation. - Ruperto-Carola University of Heidelberg. - 2020"],"physDesc":[{"extent":"1 Online-Ressource (iii, 97 Seiten)","noteIll":"Illustrationen, Diagramme"}],"recId":"1691060178"} | ||
| SRT | |a DORSCHSTEFMEASUREMEN1820 | ||