Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene

In total hip arthroplasty, osteolysis of the acetabulum often occurs at the backside of cups in the area of screw holes, indicating a clinically relevant amount of polyethylene (PE) wear particles in this area. In order to avoid a possible migration of wear particles to the acetabulum-bone, screw ho...

Full description

Saved in:
Bibliographic Details
Main Authors: Braun, Steffen (Author) , Müller, Ulrike (Author) , Schröder, Stefan (Author) , Sonntag, Robert (Author) , Bormann, Therese (Author) , Kretzer, Jan Philippe (Author)
Format: Article (Journal)
Language:English
Published: 30 July 2019
In: Acta biomaterialia
Year: 2019, Volume: 97, Pages: 239-246
ISSN:1878-7568
DOI:10.1016/j.actbio.2019.07.050
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.actbio.2019.07.050
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S1742706119305392
Get full text
Author Notes:Steffen Braun, Shirin Vardag, Ulrike Mueller, Stefan Schroeder, Robert Sonntag, Therese Bormann, Tobias Gotterbarm, Jan Philippe Kretzer

MARC

LEADER 00000caa a2200000 c 4500
001 1692658352
003 DE-627
005 20220818013725.0
007 cr uuu---uuuuu
008 200316s2019 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.actbio.2019.07.050  |2 doi 
035 |a (DE-627)1692658352 
035 |a (DE-599)KXP1692658352 
035 |a (OCoLC)1341310548 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Braun, Steffen  |d 1988-  |e VerfasserIn  |0 (DE-588)1149869429  |0 (DE-627)1010183974  |0 (DE-576)496872729  |4 aut 
245 1 0 |a Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene  |c Steffen Braun, Shirin Vardag, Ulrike Mueller, Stefan Schroeder, Robert Sonntag, Therese Bormann, Tobias Gotterbarm, Jan Philippe Kretzer 
264 1 |c 30 July 2019 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.03.2020 
520 |a In total hip arthroplasty, osteolysis of the acetabulum often occurs at the backside of cups in the area of screw holes, indicating a clinically relevant amount of polyethylene (PE) wear particles in this area. In order to avoid a possible migration of wear particles to the acetabulum-bone, screw hole plugs are provided for some implant systems. The aims of this study were to quantitatively determine backside wear and to investigate the migration behaviour of articulation-related wear particles in a cup system with open and closed screw holes by plugs. Titanium cup systems with backside holes for screw fixations were sinusoidally loaded with 2.7kN. The articulation area was separated from the backside area of the cup. A defined amount of articulation-generated particles was added to the fluid of the articulation chamber. The fluids in the two chambers were separately filtered after 2×106 cycles for a particle analysis. Backside wear with noticeably small (65.6±4.2nm) and round PE particles was identified. With both open and closed screw holes, a migration of the articulating wear particles from the articulation area behind the cup could be observed. Backside wear was estimated to be below 1% of the articulated wear. Screw hole plugs did not effectively prevent the migration of PE wear particles behind the investigated cups. - Statement of Significance - Backside wear occurs in a proven cup-system. Furthermore, it was quantitatively observed that articulation-generated wear products could migrate from the articulating area along the cup/liner-interface through the screw holes behind the cup. An almost unimpeded particle migration to the acetabulum-bone, in conjunction with very small backside wear particles, could produce a clinically relevant amount of PE with respect to pelvic lysis. These findings highlight the importance of management to avoid particle migration in artificial hip cups. Therefore, primarily the use of screw hole plugs, as far as available for the respective cup-system, is recommended. The aim of avoiding particle migration by plugs, but also by using a sophisticated anchoring mechanism between cup and PE liner should continue in future. 
650 4 |a Backside wear 
650 4 |a Hip cup system 
650 4 |a Particle migration 
650 4 |a Screw hole plugs 
650 4 |a Total hip replacement 
700 1 |a Müller, Ulrike  |d 1988-  |e VerfasserIn  |0 (DE-588)1116644002  |0 (DE-627)870607081  |0 (DE-576)478555504  |4 aut 
700 1 |a Schröder, Stefan  |d 1989-  |e VerfasserIn  |0 (DE-588)1191520447  |0 (DE-627)1670141438  |4 aut 
700 1 |a Sonntag, Robert  |e VerfasserIn  |0 (DE-588)1068843756  |0 (DE-627)82081699X  |0 (DE-576)428211135  |4 aut 
700 1 |a Bormann, Therese  |e VerfasserIn  |0 (DE-588)1205894829  |0 (DE-627)1691740136  |4 aut 
700 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
773 0 8 |i Enthalten in  |t Acta biomaterialia  |d [Amsterdam] : Elsevier, 2005  |g 97(2019), Seite 239-246  |h Online-Ressource  |w (DE-627)477531210  |w (DE-600)2173841-5  |w (DE-576)255605226  |x 1878-7568  |7 nnas  |a Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene 
773 1 8 |g volume:97  |g year:2019  |g pages:239-246  |g extent:8  |a Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene 
856 4 0 |u https://doi.org/10.1016/j.actbio.2019.07.050  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1742706119305392  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200316 
993 |a Article 
994 |a 2019 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |d 50000  |e 910000PK136998348  |e 911460PK136998348  |e 50000PK136998348  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 8  |y j 
998 |g 1205894829  |a Bormann, Therese  |m 1205894829:Bormann, Therese  |d 910000  |d 911460  |e 910000PB1205894829  |e 911460PB1205894829  |k 0/910000/  |k 1/910000/911460/  |p 6 
998 |g 1068843756  |a Sonntag, Robert  |m 1068843756:Sonntag, Robert  |d 910000  |d 911460  |e 910000PS1068843756  |e 911460PS1068843756  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 1191520447  |a Schröder, Stefan  |m 1191520447:Schröder, Stefan  |d 910000  |d 911460  |e 910000PS1191520447  |e 911460PS1191520447  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1116644002  |a Müller, Ulrike  |m 1116644002:Müller, Ulrike  |d 910000  |d 911460  |e 910000PM1116644002  |e 911460PM1116644002  |k 0/910000/  |k 1/910000/911460/  |p 3 
998 |g 1149869429  |a Braun, Steffen  |m 1149869429:Braun, Steffen  |d 910000  |d 911460  |e 910000PB1149869429  |e 911460PB1149869429  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1692658352  |e 3609032200 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","given":"Steffen","display":"Braun, Steffen","family":"Braun"},{"role":"aut","given":"Ulrike","display":"Müller, Ulrike","family":"Müller"},{"display":"Schröder, Stefan","family":"Schröder","given":"Stefan","role":"aut"},{"role":"aut","given":"Robert","family":"Sonntag","display":"Sonntag, Robert"},{"role":"aut","given":"Therese","display":"Bormann, Therese","family":"Bormann"},{"given":"Jan Philippe","role":"aut","display":"Kretzer, Jan Philippe","family":"Kretzer"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene","title":"Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene"}],"note":["Gesehen am 16.03.2020"],"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"30 July 2019"}],"id":{"eki":["1692658352"],"doi":["10.1016/j.actbio.2019.07.050"]},"relHost":[{"language":["eng"],"part":{"pages":"239-246","year":"2019","volume":"97","extent":"8","text":"97(2019), Seite 239-246"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"477531210","id":{"eki":["477531210"],"issn":["1878-7568"],"zdb":["2173841-5"]},"title":[{"title_sort":"Acta biomaterialia","title":"Acta biomaterialia"}],"pubHistory":["1.2005 -"],"note":["Gesehen am 09.09.2020"],"origin":[{"dateIssuedKey":"2005","publisher":"Elsevier","dateIssuedDisp":"2005-","publisherPlace":"[Amsterdam]"}],"disp":"Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethyleneActa biomaterialia","type":{"media":"Online-Ressource","bibl":"periodical"}}],"recId":"1692658352","physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Steffen Braun, Shirin Vardag, Ulrike Mueller, Stefan Schroeder, Robert Sonntag, Therese Bormann, Tobias Gotterbarm, Jan Philippe Kretzer"]}} 
SRT |a BRAUNSTEFFBACKSIDEWE3020